168 research outputs found
A Novel Approach for an Integrated Straw tube-Microstrip Detector
We report on a novel concept of silicon microstrips and straw tubes detector,
where integration is accomplished by a straw module with straws not subjected
to mechanical tension in a Rohacell lattice and carbon fiber
reinforced plastic shell. Results on mechanical and test beam performances are
reported on as well.Comment: Accepted by Transactions on Nuclear Science (2005). 11 pages, 9
figures, uses lnfprep.st
Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC
proton collider (CERN, Switzerland) will employ an online gas analysis and
monitoring system of the freon-based gas mixture used. We give an overview of
the CMS RPC gas system, describe the project parameters and first results on
gas-chromatograph analysis. Finally, we report on preliminary results for a set
of monitor RPC.Comment: 9 pages, 8 figures. Presented by Stefano Bianco (Laboratori Nazionali
di Frascati dell'INFN) at the IEEE NSS, San Diego (USA), October 200
The CMS RPC gas gain monitoring system: an overview and preliminary results
The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the
Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported
on. The GGM system is a cosmic ray telescope based on small RPC detectors
operated with the same gas mixture used by the CMS RPC system. The GGM gain and
efficiency are continuously monitored on-line, thus providing a fast and
accurate determination of any shift in working point conditions. The
construction details and the first result of GGM commissioning are described.Comment: 8 pages, 9 figures, uses lnfprepCMS.sty, presented by L. Benussi at
RPC07, Mumbai, INDIA 200
Micrometric Position Monitoring Using Fiber Bragg Grating Sensors in Silicon Detectors
We show R&D results including long term stability, resolution, radiation
hardness and characterization of Fiber Grating sensors used to monitor
structure deformation, repositioning and surveying of silicon detector in High
Energy Physics.Comment: Presented by S.Bianco at ICATPP05, Villa Olmo (Como) Italy, November
2005. 5 pages, 6 figures, uses lnfprep.st
Two- and Three-Dimensional Reconstruction and Analysis of the Straw Tubes Tomography in the Btev Experiment
A check of the eccentricity of the aluminised kapton straw tubes used in the
BTeV experiment is accomplished using X-ray tomography of the section of tubes
modules. 2 and 3-dimensional images of the single tubes and of the modules are
reconstructed and analysed. Preliminary results show that a precision better
than 40 m can be reached on the measurement of the straw radii.Comment: Presented by F.Massa at ICATPP05, Villa Olmo (Como) Italy, November
2005. 4 pages, 8 figures, uses lnfprep.st
Gas analysis and monitoring systems for the RPC detector of CMS at LHC
1-9, arXiv:physics/0701014. Publisher: Los AlamosNational Laboratoty, CODEN: LNPHF9
available at
http://arxiv.org/PS_cache/physics/pdf/0701/0701014v1.pd
A new approach in modeling the response of RPC detectors
The response of RPC detectors is highly sensitive to environmental variables.
A novel approach is presented to model the response of RPC detectors in a
variety of experimental conditions. The algorithm, based on Artificial Neural
Networks, has been developed and tested on the CMS RPC gas gain monitoring
system during commissioning
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
- …