91 research outputs found

    CT and MR enterography in evaluating small bowel diseases: when to use which modality?

    No full text
    MR and CT techniques optimized for small bowel imaging are playing an increasing role in the evaluation of small bowel disorders. Several studies have shown the advantages of these techniques over traditional barium fluoroscopic examinations due to improvements in spatial and temporal resolution combined with improved bowel distending agents. The preference of MR vs. CT has been geographical and based on expertise and public policy. With the increasing awareness of radiation exposure, there has been a more global interest in implementing techniques that either reduce or eliminate radiation exposure. This is especially important in patients with chronic diseases such as inflammatory bowel disease who may require multiple studies over a lifetime or in studies that require sequential imaging time points such as in assessment of gastrointestinal motility. MRI has many properties that make it well suited to imaging of the small bowel: the lack of ionizing radiation, the improved tissue contrast that can be obtained by using a variety of pulse sequences, and the ability to perform real time functional imaging. Moreover, MR modalities allow visualization of the entire bowel, without overlapping bowel loops, as well as the detection of both intra- and extraluminal abnormalities.The intra- and extraluminal MR findings, combined with contrast enhancement and functional information, help to make an accurate diagnosis and consequently characterize small bowel diseases

    Prostate cancer: value of magnetic resonance spectroscopy 3D chemical shift imaging

    No full text
    The results of recent studies of magnetic resonance imaging (MRI) combined with three-dimensional magnetic resonance spectroscopic imaging (3D-MRSI) demonstrate that the MRI/3D-MRSI exam is a unique method by which to noninvasively study the, cellular metabolism and anatomy of the prostate. 3D-MRSI is emerging as the most specificity tool for non-invasive evaluation of the prostate cancer. The results of current MRI/3D-MRSI studies also provide evidence that the magnitude of metabolic changes in regions of cancer before therapy, as well as the extent of the time course of metabolic changes after therapy, may improve our understanding of cancer aggressiveness. Assessment of cancer spread outside the prostate can be significantly improved by combining MRI findings with estimates of metabolic abnormalities provided by 3D-MRSI. Clinically, combined MRI/3D-MRSI has already demonstrated a potential for improved diagnosis, staging, and treatment planning for patients with prostate cancer. This article reviewed the value of 3D-MRS imaging for the diagnosis, localization, staging, aggressiveness, and treatment planning of prostate cancer

    Hilar cholangiocarcinoma: MRI/MRCP in staging and treatment planning

    No full text
    The role of MR imaging in hilar cholangiocarcinoma is to confirm/reach a diagnosis and to assess resectability. Hilar cholangiocarcinoma shows the same signal intensity pattern of peripheral tumors both on T1- and T2-weighted images. On magnetic resonance cholangiopancreatography (MRCP) images, hilar cholangiocarcinoma appears as a moderately irregular thickening of the bile duct wall (5 mm) with symmetric upstream dilation of the intrahepatic bile ducts. The aim of preoperative investigation in Klatskin tumors typically requires the evaluation of the level of biliary obstruction, the intrahepatic tumor spread, and the vascular involvement; it also needs to show any atrophy-hypertrophy complex. Because of its intrinsic high tissue contrast and multiplanar capability, MR imaging and MRCP are able to detect and preoperatively assess patients with cholangiocarcinoma, investigating all involved structures such as bile ducts, vessels and hepatic parenchyma. The main reason for surgical/imaging discrepancy is represented by the microscopic diffusion along the mucosa and in the perineural space

    Crohn disease of the small bowel: MR enteroclysis versus conventional enteroclysis

    No full text
    Enteroclysis has been suggested as the technique of choice for the evaluation of Crohn disease of the small intestine. Adequate distention of the entire small bowel with barium suspension allows the radiologic demonstration of mucosal abnormalities and provides functional information by defining distensibility or fixation of the small bowel loops. The principal disadvantage of conventional enteroclysis is the limited indirect information on the state of the bowel wall and extramural extension of Crohn disease, and its effectiveness may be hindered owing to overlapping bowel loops. Moreover, the radiation dose administered to patients, mostly at a young age, should be considered. Magnetic resonance (MR) enteroclysis is an emerging technique for small bowel imaging and was introduced to overcome the limitations of conventional enteroclysis and MR cross-sectional imaging by combining the advantages of both into one technique. MR enteroclysis has the potential to change how the small bowel is assessed because of the functional information, soft tissue contrast, direct multiplanar imaging capabilities, and lack of ionizing radiation

    Comparison of MR enteroclysis with MR enterography and conventional enteroclysis in patients with Crohn's disease.

    No full text
    To prospectively compare the diagnostic accuracy of MR enteroclysis with duodenal intubation with MRI after drinking oral contrast agent only (MR enterography) with conventional enteroclysis (conv-E) as reference standard in patients with Crohn's disease. Forty consecutive patients (22 males and 18 females; mean age 36; range 16-74 years) with proven Crohn's disease underwent conv-E and MR imaging. Twenty-two patients underwent MR enteroclysis with intubation (MRE) and 18 underwent MR-enterography (MR per OS). Two radiologists reached a consensus about the following imaging findings: luminal distension and visualization of superficial mucosal, mural and mesenteric abnormalities. Standard descriptive statistics and a Wilcoxon rank sum test were used. Statistical significance was inferred at P < 0.05. There was no significant difference in the adequacy of luminal distention between the MRE and conv-E (P = 0.08), and both were statistically superior in comparison to MR per OS in the distension of the jejunum (P < 0.01) and less significant at the ileum and terminal ileum levels (P < 0.05). MRE and conv-E were comparable for the accuracy of superficial mucosal abnormalities; meanwhile conv-E compared with MR per OS was statistically superior (P < 0.01). MRE compared with MR per OS was statistically better when visualizing superficial abnormalities (P < 0.01). No statistically significant differences were found in assessing the diagnostic efficacy between MR examinations for the depiction of mural stenosis (P = 0.105) and fistulae (P = 0.67). The number of detected mesenteric findings was significantly higher with both MRE and MR per OS compared to conv-E (P < 0.01). MRE can serve as the diagnostic procedure for initially evaluating patients suspected of having Crohn's disease. MR per OS may have a role in patients that refuse or have failed intubation and also for follow-up

    Child abuse: imaging of multiorgan damages

    No full text
    An abused child can present with every lesion known to medicine, but some of these lesions can be specific of child abuse. The most frequent skeletal lesions are that of the long bones, of the head and the chest. Head damages are responsible for 80\% of the dead in abused child. These kind of lesions are very important because they can produce important neurological deficits. Most frequent are extraxial bleeding and intraparenchimal lesions. Abdominal damages are the second cause of dead in the abused child. They can be asymptomatic and so they can be misdiagnosed. They are not so frequent but if they are present, they are letal. Conventional radiology, CT and MRI are very important in the management of child abuse because they allow to reveal multiorgan damages which, in some instances, can be specific of a child abuse

    Magnetic resonance imaging of clinically stable late pregnancy bleeding: beyond ultrasound

    No full text
    To compare the accuracy of magnetic resonance (MRI) and colour Doppler-ultrasound (US) in the diagnosis of late pregnancy bleeding and to assess the accuracy of the different MR sequences in visualizing the origin of haemorrhage. 42 patients in the third trimester of pregnancy underwent to US and MRI for the evaluation of painless vaginal bleeding. Multiplanar HASTE, True Fisp, 3D T1 GRE and sagittal DWI sequences were acquired. Two radiologists, blinded to the results of US, reviewed each case, resolving by consensus any discrepancy. Reference standards were surgical and pathological findings. The reference standards identified 22 placenta previa, 11 placental abruptions (1 coincident with a placental chorioangioma), 1 thrombohaematoma and 1 fibroma with haemorrhagic degeneration. MRI identified correctly all these condition with an interobserver agreement of 0.955. DWI and T1 weighted sequences were statistically superior to Haste and True Fisp sequences in detecting the cause of bleeding (p < .001). US had 6 false negatives and 2 false positive results, its diagnostic accuracy resulting lower than MRI (p = .001). MRI accurately evaluates pregnancy bleeding with an excellent interobserver agreement and can grant new and additional data when US is negative
    • …
    corecore