2 research outputs found
Recommended from our members
Impact of the International Nosocomial Infection Control Consortium (INICC)’s multidimensional approach on rates of ventilator-associated pneumonia in intensive care units in 22 hospitals of 14 cities of the Kingdom of Saudi Arabia
To analyze the impact of the International Nosocomial Infection Control Consortium (INICC) Multidimensional Approach (IMA) and use of INICC Surveillance Online System (ISOS) on ventilator-associated pneumonia (VAP) rates in Saudi Arabia from September 2013 to February 2017.
A multicenter, prospective, before–after surveillance study on 14,961 patients in 37 intensive care units (ICUs) of 22 hospitals. During baseline, we performed outcome surveillance of VAP applying the definitions of the CDC/NHSN. During intervention, we implemented the IMA and the ISOS, which included: (1) a bundle of infection prevention practice interventions, (2) education, (3) outcome surveillance, (4) process surveillance, (5) feedback on VAP rates and consequences and (6) performance feedback of process surveillance. Bivariate and multivariate regression analyses were performed using generalized linear mixed models to estimate the effect of intervention.
The baseline rate of 7.84 VAPs per 1000 mechanical-ventilator (MV)-days―with 20,927 MV-days and 164 VAPs―, was reduced to 4.74 VAPs per 1000 MV-days―with 118,929 MV-days and 771 VAPs―, accounting for a 39% rate reduction (IDR 0.61; 95% CI 0.5–0.7; P 0.001).
Implementing the IMA was associated with significant reductions in VAP rates in ICUs of Saudi Arabia
International Nosocomial Infection Control Consortium report, data summary of 50 countries for 2010-2015: Device-associated module
•We report INICC device-associated module data of 50 countries from 2010-2015.•We collected prospective data from 861,284 patients in 703 ICUs for 3,506,562 days.•DA-HAI rates and bacterial resistance were higher in the INICC ICUs than in CDC-NHSN's.•Device utilization ratio in the INICC ICUs was similar to CDC-NHSN's.
Background: We report the results of International Nosocomial Infection Control Consortium (INICC) surveillance study from January 2010-December 2015 in 703 intensive care units (ICUs) in Latin America, Europe, Eastern Mediterranean, Southeast Asia, and Western Pacific.
Methods: During the 6-year study period, using Centers for Disease Control and Prevention National Healthcare Safety Network (CDC-NHSN) definitions for device-associated health care-associated infection (DA-HAI), we collected prospective data from 861,284 patients hospitalized in INICC hospital ICUs for an aggregate of 3,506,562 days.
Results: Although device use in INICC ICUs was similar to that reported from CDC-NHSN ICUs, DA-HAI rates were higher in the INICC ICUs: in the INICC medical-surgical ICUs, the pooled rate of central line-associated bloodstream infection, 4.1 per 1,000 central line-days, was nearly 5-fold higher than the 0.8 per 1,000 central line-days reported from comparable US ICUs, the overall rate of ventilator-associated pneumonia was also higher, 13.1 versus 0.9 per 1,000 ventilator-days, as was the rate of catheter-associated urinary tract infection, 5.07 versus 1.7 per 1,000 catheter-days. From blood cultures samples, frequencies of resistance of Pseudomonas isolates to amikacin (29.87% vs 10%) and to imipenem (44.3% vs 26.1%), and of Klebsiella pneumoniae isolates to ceftazidime (73.2% vs 28.8%) and to imipenem (43.27% vs 12.8%) were also higher in the INICC ICUs compared with CDC-NHSN ICUs.
Conclusions: Although DA-HAIs in INICC ICU patients continue to be higher than the rates reported in CDC-NSHN ICUs representing the developed world, we have observed a significant trend toward the reduction of DA-HAI rates in INICC ICUs as shown in each international report. It is INICC's main goal to continue facilitating education, training, and basic and cost-effective tools and resources, such as standardized forms and an online platform, to tackle this problem effectively and systematically