6 research outputs found

    Does creatine kinase-MB (CK-MB) isoenzyme elevation following percutaneous coronary intervention with drug-eluting stents impact late clinical outcome?

    No full text
    BACKGROUND: The incidence of postprocedural creatine kinase (CK)-MB elevation to >3x the upper limit of normal after percutaneous coronary intervention (PCI) has been reported at rates of up to 18% in the bare metal stent era and is correlated with higher adverse cardiovascular outcomes. This study examined the incidence and prognostic significance of CK-MB elevations after drug-eluting stent (DES) implantation. METHODS: The records of 2,537 patients who underwent DES implantation and completed > or =6 months' follow-up were evaluated. Patients with acute myocardial infarction and those who presented in cardiogenic shock and had elevated cardiac enzymes at baseline were excluded from the analysis. Of these, 179 patients (7.1%) had > or =3x postprocedural CK-MB and 2,358 patients had or =3x elevation had a higher number of diseased vessels (2.15 +/- 0.86 vs. 1.81 +/- 0.87; P or =3x elevation following PCI with DES continues to be a marker for the complexity of coronary disease and lack of clinical success; and correlates with higher rates of subacute thrombosis as well as late adverse events at 6-months and 1-year postprocedure.6 page(s

    Correlates of clinical restenosis following intracoronary implantation of drug-eluting stents

    No full text
    Despite significant decreases in restenosis and repeated intervention achieved using drug-eluting stents (DESs), the benefit has not been homogenous across all patient and lesion subsets. Identification of correlates of DES restenosis may allow a differing management approach and lead to improved patient outcomes. The study population consisted of 3,535 consecutive patients (5,046 lesions) who underwent successful sirolimus- or paclitaxel-eluting stent implantation for >or=1 native coronary artery or bypass graft lesion from April 2003 to September 2006. From this cohort, 197 patients (237 lesions) were identified to have in-stent restenosis (ISR) requiring revascularization within 12 months of stent implantation. This group was compared with the remainder of the patient population. Logistic regression analysis was performed to identify independent predictors of DES ISR. Independent correlates of DES ISR using multivariate analysis included both clinical and procedural factors. Clinical predictors were age, hypertension, and unstable angina. Procedural predictors were left anterior descending artery intervention, number of stents implanted, stented length/lesion, and lack of intravascular ultrasound guidance. Implantation of >or=3 stents was associated with a significantly higher restenosis risk (9.7% vs 5.1%; p=0.0003). A 10-mm increase in stented length was associated with an adjusted odds ratio of 1.18 (95% confidence interval 1.03 to 1.35). Diabetes, stent diameter, and stent type were found not to be predictive of DES ISR. In conclusion, correlates of DES ISR included both clinical and procedural factors. Limiting the number of stents and stented length, in addition to intravascular ultrasound guidance, may minimize DES ISR.5 page(s

    Comparison between sirolimus- and paclitaxel-eluting stents in complex patient and lesions subsets

    No full text
    BACKGROUND: Sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) both significantly reduce the need for repeat intervention compared to bare metal stents. Studies comparing the clinical outcomes of these stents in noncomplex subsets of patients and lesions demonstrate a similar safety and efficacy profile. The data for more complex subsets of patients and lesions remains conflicting. This study aimed to compare SES with PES in a selected population with a broad range of complex features. METHODS AND RESULTS: The patient population consisted of 1,591 consecutive patients with complex features undergoing drug-eluting stent (DES) implantation. In the SES group there were 1,095 patients (1,653 lesions) and in the PES group 496 patients (802 lesions). In-hospital, 30-day, and 12-month clinical outcomes were compared between groups. No discernable difference in major adverse cardiac events (MACE) between SES and PES was detected at intermediate and longer-term follow-up (SES 22.4% vs. PES 20.5% at 12 months; P=0.407). A trend toward increased angiographically documented stent thrombosis was observed in the SES group at both 3 and 12 months (SES 2.2% vs. PES 0.8% at 12 months; P=0.051). When adopting the more inclusive definition of probable stent thrombosis, this trend was no longer seen. After adjusting for baseline differences between the two groups, there still remained no difference in MACE between SES and PES (HR 1.051 [CI 0.826-1.339] P=0.685). The trend toward increased angiographically documented stent thrombosis in the SES group remained after adjustment for baseline differences (HR 2.836 [CI 0.968-8.311] P=0.057). CONCLUSIONS: In a selected population with complex disease the rate of MACE was comparable between SES and PES, with higher overall rates of thrombosis and MACE compared to a noncomplex population. Thus, the focus should be directed to prevent late complications in this complex subset regardless of stent type selection.6 page(s

    Treatment of drug-eluting stent restenosis with the same versus different drug-eluting stent

    No full text
    OBJECTIVE: The authors aimed to compare the clinical outcomes with repeat drug-eluting stent (DES) implantation utilizing the same type versus an alternate DES type for in-stent restenosis (ISR) of DES. BACKGROUND: : DES are proven as an effective treatment for bare metal ISR. METHODS: A cohort of 116 patients previously treated with a sirolimus-eluting stent (SES) or a paclitaxel-eluting stent (PES) who presented with angiographic ISR were treated with repeat DES. Of these, 62 (53.4%) were treated with different DES and 54 (46.6%) were treated with the same DES. This cohort was followed for clinical events at 30 days, 6 months, and 1 year. RESULTS: Baseline characteristics were similar except for more diabetes among patients receiving the different type of DES. Of the 116, overall 16.4% of the DES were implanted for previous ISR and 2.6% had previously received brachytherapy. At 6 months, the overall target vessel revascularization (TVR) rate was 12.2% for the entire cohort. The TVR-major adverse cardiac event (MACE) rate for the patients treated with different DES was 14.5% and 16.7% for the same DES (P = 0.750). Overall TVR rate at 1 year was 28.8%. The TVR-MACE was 32.6% for different DES and 35.0% for the same DES (P = 0.814). CONCLUSIONS: Reimplantation of DES for the treatment of DES ISR (same or different) is safe but associated with a high rate of recurrences at 1 year regardless of the initial DES type. Other treatment modalities for ISR of DES should be considered to further improve the overall TVR-MACE.6 page(s

    Intravascular ultrasound parameters associated with stent thrombosis after drug-eluting stent deployment

    No full text
    Drug-eluting stent (DES) thrombosis (ST) can be devastating. The study aim was to evaluate intravascular ultrasound (IVUS) predictors for DES thrombosis by comparing IVUS studies after implantation in 13 patients with 14 DES thrombosis lesions with a group of controls (30 lesions in 27 patients) matched for history of chronic renal failure and type of DES. Five patients (38%) discontinued dual antiplatelet therapy at the time of ST. There were 3 in-stent restenosis lesions (21%) treated using DESs in the ST group compared with 0 in the control group (p <0.05). Compared with the control group, IVUS studies in the ST group showed a smaller minimum stent area (4.6 +/- 1.1 vs 5.6 +/- 1.7 mm(2), p = 0.0489). In the ST group, 11 of 14 stents had a minimum stent area < or =5.0 mm(2) compared with 12 of 30 in the control group (p = 0.0392). Minimum stent area in patients who stopped clopidogrel therapy and developed ST (5.30 +/- 1.15 mm(2)) tended to be larger compared with that in patients who developed ST while using clopidogrel (4.24 +/- 0.96 mm(2), p = 0.091). Within the 5-mm-long proximal and distal reference segments analyzed, the ST group had larger proximal reference maximum plaque burdens and smaller minimum lumen areas, along with a tendency toward similar findings in the distal reference segments. In conclusion, IVUS findings at the time of DES implantation in patients who subsequently developed ST showed a smaller minimum stent area (especially in patients who developed ST while using clopidogrel) and more residual disease at the stent edges.6 page(s

    Outcomes of coronary artery bypass grafting versus percutaneous coronary intervention with drug-eluting stents for patients with multivessel coronary artery disease

    No full text
    BACKGROUND: Advances in coronary artery bypass grafting (CABG) surgery and percutaneous coronary intervention (PCI) with drug-eluting stents have dramatically improved results of these procedures. The optimal treatment for patients with multivessel coronary artery disease is uncertain given the lack of prospective, randomized data reflecting current practice. This study represents a "real-world" evaluation of current technology in the treatment of multivessel coronary artery disease. METHODS AND RESULTS: A total of 1680 patients undergoing revascularization for multivessel coronary artery disease were identified. Of these, 1080 patients were treated for 2-vessel disease (196 CABG and 884 PCI) and 600 for 3-vessel disease (505 CABG and 95 PCI). One-year mortality, cerebrovascular events, Q-wave myocardial infarction, target vessel failure, and composite major adverse cardiovascular and cerebrovascular events were compared between the CABG and PCI cohorts. Outcomes were adjusted for baseline covariates and reported as hazard ratios. The unadjusted major adverse cardiovascular and cerebrovascular event rate was reduced with CABG for patients with 2-vessel disease (9.7% CABG versus 21.2% PCI; P<0.001) and 3-vessel disease (10.8% CABG versus 28.4% PCI; P<0.001). Adjusted outcomes showed increased major adverse cardiovascular and cerebrovascular event with PCI for patients with 2-vessel (hazard ratio 2.29; 95% CI 1.39 to 3.76; P=0.01) and 3-vessel disease (hazard ratio 2.90; 95% CI 1.76 to 4.78; P<0.001). Adjusted outcomes for the nondiabetic subpopulation demonstrated equivalent major adverse cardiovascular and cerebrovascular event with PCI for 2-vessel (hazard ratio 1.77; 95% CI 0.96 to 3.25; P=0.07) and 3-vessel disease (hazard ratio 1.70; 95% CI 0.77 to 3.61; P=0.19). CONCLUSIONS: Compared with PCI with drug-eluting stents, CABG resulted in improved major adverse cardiovascular and cerebrovascular event in patients with 2- and 3-vessel coronary artery disease, primarily in those with underlying diabetes. Coronary artery bypass surgery may be the preferred revascularization strategy in diabetic patients with multivessel coronary artery disease