    Robustness evaluation of the chromatographic method for the quantitation of lumefantrine using Youden's test

    Get PDF
    O teste de Youden constitui um método confiável para avaliação da robustez de métodos analíticos, por meio de um delineamento que envolve sete parâmetros analíticos combinados em oito experimentos. No presente estudo, a robustez de um método cromatográfico para quantificação de lumefantrina em matéria-prima farmacêutica foi avaliada utilizando-se o teste de Youden. Assim, foi possível determinar o efeito de cada parâmetro analítico nos resultados finais das análises. O teste de Youden se mostrou um procedimento simples e confiável para a avaliação da robustez de métodos cromatográficos.Youden's test is a reliable method to evaluate the robustness of analytical methods, by means of an experiment design which involves seven analytical parameters combined in eight tests. In the present study, we assessed the robustness of a chromatographic method to quantify lumefantrine in raw material samples, using Youden's test. Hence, it was possible to determine the effect of each analytical parameter in the final analysis results. Youden's test showed to be a simple and feasible procedure to evaluate the robustness of chromatographic methods

    An innovative, simple, fast, and less toxic high-performance liquid chromatographic method for determination of prednisone in capsules

    Get PDF
    Prednisone is an anti-inflammatory steroid drug widely used in clinical practice. However, no high-performance liquid chromatographic (HPLC) method has been described in the literature for the determination of prednisone in capsules until now. Thus, an HPLC method was developed using a C18 (250x4.0, 5 µm) column, with methanol:water (70:30) as mobile phase at a flow rate of 1 mL/min and detection at 240 nm. The developed method was validated following current Brazilian legislation. Additionally, linearity was assessed by evaluating the assumptions of normality, homoscedasticity, and independency of residuals, and the fit to the linear model. The method showed linearity (r2>;0.99) over the range of 14.0-26.0 µg/mL, selectivity, precision (RS

    Development and validation of a stability indicating HPLC method to determine diltiazem hydrochloride in tablets and compounded capsules

    Get PDF
    A stability indicating HPLC method to determine diltiazem hydrochloride (DTZ) in tablets and compounded capsules was developed and validated according to Brazilian and the International Conference on Harmonization (ICH) guidelines. The separation was carried out on a Purospher Star® C18 (150 x 4.6 mm i.d., 5 µm particle size, Merck Millipore) analytical column. The mobile phase consisted of a 0.05% (v/v) trifluoroacetic acid aqueous solution and a 0.05% trifluoroacetic acid methanolic solution (44:56, v/v). The flow rate was 1.0 mL.min-1 with a run time of 14 minutes. The detection of DTZ and degradation products (DP) was performed at 240 nm, using a diode array detector. The method proved to be linear, precise, accurate, selective, and robust, and was adequate for stability studies and routine quality control analyses of DTZ in tablets and compounded capsules

    Rapid stability-indicating UHPLC method for determination of lamivudine and tenofovir disoproxil fumarate in fixed-dose combination tablets

    Get PDF
    Lamivudine (3TC) and tenofovir disoproxil fumarate (TDF) are antiretroviral drugs widely used for AIDS treatment. Since safety, efficacy and quality are essential for drug products, stability studies must be performed. Therefore, degradation studies must be carried out to evaluate the degradation products formed. The active pharmaceutical ingredients 3TC and TDF, as well as the tablets containing the combination of these drugs were subjected to a comprehensive forced degradation. 3TC, TDF and the degradation products were analyzed by a stability-indicating ultra-high performance liquid chromatography (UHPLC) method developed and validated. A C8 (100 x 2.0 mm, 2.2 μm) column and a mobile phase composed of 0.1 M ammonium acetate buffer pH 4.0, acetonitrile and methanol in gradient elution, at 0.5 mL/min, were used. The injection volume was 4 μL and detection was at 260 nm. The method was selective, precise, accurate and linear in the range 0.1-0.6 mg mL-1 for the two drugs. 3TC was degraded in acidic, alkaline and oxidative environment and in the presence of metal ions. Two degradation products were observed. TDF was degraded in the same conditions than those 3TC was labile. In addition, TDF was degraded in neutral condition. Again, two degradation products were formed. Chemical structures were proposed for the degradation products using UHPLC-QTOF/MS. The stability-indicating method developed showed to be useful in stability studies and in the quality control of fixed-dose combination tablets containing 3TC and TDF

    Development and validation of an HPLC method for the simultaneous determination of artesunate and mefloquine hydrochloride in fixed-dose combination tablets

    Get PDF
    The present study developed and validated an HPLC method for the simultaneous determination of artesunate (AS) and mefloquine hydrochloride (MQ) in fixed-dose combination tablets, according to ICH guidelines. The chromatographic separation was carried out on an XBridge C18 (250 x 4.6 mm i.d., 5 µm particle size, Waters) analytical column. The mobile phase included a 0.05 M monobasic potassium phosphate buffer (pH adjusted to 3.0 with phosphoric acid) and acetonitrile (50 + 50, v/v). The flow rate was 1.0 mL/min, and the run time was 13 minutes. A dual-wavelength approach was employed: AS detection was performed at 210 nm and MQ was detected at 283 nm, using a diode array detector. Stability of sample solutions was evaluated for 8 hours after preparation, during which time the solutions remained stable. Youden's test was employed to evaluate robustness. The method proved to be linear (r²>;0.99), precise (RSDUm método por cromatografia a líquido de alta eficiência para a determinação simultânea de artesunato (AS) e cloridrato de mefloquina (MQ) em comprimidos em dose fixa combinada foi desenvolvido e validado, de acordo com as normas do ICH. A separação cromatográfica foi realizada com uma coluna analítica XBridge C18 (250 x 4,6 mm d.i., partículas de 5 µm, Waters). A fase móvel foi constituída de tampão fosfato monobásico de potássio 0,05 M (pH ajustado para 3,0 com ácido fosfórico) e acetonitrila (50 + 50, v/v). O fluxo da fase móvel foi de 1,0 mL/min e o tempo de corrida foi de 13 minutos. Utilizaram-se dois comprimentos de onda: a detecção do AS foi realizada em 210 nm e a de MQ foi realizada em 283 nm, utilizando-se um detector de arranjo de diodos. A estabilidade das soluções padrão e amostra foi avaliada por 8 horas após sua preparação e as soluções permaneceram estáveis nesse período. O teste de Youden foi empregado para a avaliação da robustez do método. O método se mostrou linear (r²>;0,99), preciso (DP

    In vitro dissolution kinetic for mycophenolic acid derivatives tablets

    Get PDF
    Micofenolato de mofetila (MMF) e micofenolato sódico (MPS) são, respectivamente, éster e sal sódico do ácido micofenólico. Os fármacos possuem características farmacocinéticas distintas em função das diferenças na estrutura molecular, nas propriedades físico-químicas e nas formulações administradas. Neste trabalho, os perfis de dissolução dos medicamentos referências foram testados em diferentes meios de dissolução com o objetivo de avaliar o efeito da variação de pH, a cinética de dissolução e o modelo estatístico mais adequado para prever a dissolução dos fármacos. A liberação dos fármacos foi determinada com método validado por espectroscopia no ultravioleta, λ 250 nm. O método mostrou-se seletivo, linear, preciso e exato para dissolução de MMF em 0,1 M HCl e MPS em tampão fosfato pH 6,8. Os modelos cinéticos de dissolução de ordem zero, primeira ordem, Higuchi, Hixson-Crowell e Weibull foram aplicados com o objetivo de selecionar aquele com o melhor ajuste por regressão linear. Os parâmetros de regressão foram estimados e os ajustes dos modelos foram verificados pelos resíduos e coeficientes de determinação. Os resíduos obtidos foram aleatórios, independentes, apresentaram variância constante e seguiram a distribuição normal. Os valores de R² (74,7% para MMF e 95,8% para MPS) indicaram bom ajuste da regressão de Weibull para explicar a variabilidade e estimar a liberação dos fármacos.Mycophenolate mofetil (MMF) and mycophenolate sodium (MPS) are an ester and a salt of mycophenolic acid. They have different kinetic in vivo characteristics due to differences in molecular structures, physicochemical properties and formulations administered. In this study, dissolution profiles of reference products were tested in different media to evaluate the effect of pH, kinetic dissolution and the best statistical model that can be used to predict the release of both drugs. The drug release was determined by using a validated ultraviolet spectrophotometry method, λ 250 nm. The method showed to be selective, linear, precise and accurate for MMF in 0.1 M HCl and MPS in sodium phosphate buffer pH 6.8. Dissolution kinetics models of zero order, first order, Higuchi, Hixson-Crowell and Weibull were applied to data in order to select the best fit by linear regression. The regression parameters were estimated and the models were evaluated with the results of residuals and coefficient of determination. The residuals obtained from dissolution kinetics models were random, uncorrelated, and normally distributed with constant variance. The R² values (74.7% for MMF and 95.8% for MPS) demonstrated good ability of the Weibull regression to explain the variability and to predict the drugs' release

    Characterization of the hypoglycemic drug glibenclamide

    Get PDF
    Glibenclamide (GLIB) or glyburide, a second-generation hypoglycemic agent is orally used in the form of tablets for the treatment of diabetes mellitus. Bulk GLIB has a low aqueous solubility and it may yield low drug release in the dissolution test, causing variabilility in the treatment. This work evaluates the bulk GLIB features, which may influence drug release profile, hence, bioavailability, by means of techniques such as nitrogen sorption analysis, laser diffraction, thermal analysis, IV/UV spectroscopy and X-ray analysis.A glibenclamida (GLIB) é um fármaco de segunda geração, administrado por via oral na forma de comprimidos, utilizado para o tratamento de Diabetes mellitus. GLIB possui baixa solubilidade aquosa, o que pode levar a uma baixa liberação a partir de formas farmacêuticas sólidas no teste de dissolução e, portanto, a variabilidades no tratamento. Neste estudo, avaliam-se as características da matéria-prima GLIB, que podem influenciar o perfil de dissolução, e conseqüentemente, a biodisponibilidade, por meio de técnicas tais como, adsorção de nitrogênio, difração de raio laser, análise térmica, espectroscopia por IV/UV e difração de raios X

    Teste de dissolução para avaliação de liberação de glibenclamida em comprimidos

    Get PDF
    A glibenclamida (GLIB) ou gliburida, é um hipoglicemiante oral de segunda geração, da classe das sulfoniluréias, usado sob a forma de comprimidos para tratamento do diabetes mellitus. Variações no tratamento podem ocorrer, devido à baixa solubilidade do fármaco em comprimidos. A comparação de várias formulações de comprimidos piloto com comprimidos do medicamento referência (Daonil®, glibenclamida 5 mg comprimidos, Aventis Pharma Ltda.) foi avaliada por meio do desenvolvimento de um teste de dissolução sem adição de solventes orgânicos ou tensoativos no meio, que mostrou ser discriminativo para as diferentes formulações farmacêuticas propostas. A quantificação de GLIB foi realizada por meio de cromatografia líquida de alta eficiência em fase reversa (CLAE-FR), método previamente validado. A partir de vários ensaios de perfil de dissolução testados comparativamente àquele de comprimidos do medicamento referência, verificou-se o potencial de determinada formulação proposta (f1 4,04 and f2 69,35) como candidata a medicamento genérico no mercado brasileiro.Glibenclamide (GLIB) or glyburide, a second-generation hypoglycemic agent is used per oral as tablets for the treatment of diabetes mellitus. Much variabilility in the treatment may occur because of the low drug aqueous solubility in tablets dosage forms. This work reports the comparison of several pilot formulation batches with the commercial reference drug dosage form (Daonil®, glibenclamide 5 mg per tablet, Aventis Pharma Ltda.). A feasible dissolution test, developed with no use of organic solvents or surfactants in the medium, showed to be discriminative regarding to different formulations tested. GLIB quantitation was performed by a previously validated reverse-phase high performance liquid chromatography (RP-HPLC). Among several dissolution profiles compared with that of a commercial reference, a potential for a generic candidate was evident (f1 4.04 and f2 69.35) for a proposed solid dosage formulation in the Brazilian market

    Comparison of microbiological assay and HPLC-UV for determination of fluconazole in capsules

    Get PDF
    The development of a specific agar diffusion bioassay for the quantitative determination of fluconazole formulated in capsules was carried out using a strain of Candida albicans ATCC 18804 as the test organism. A prospective validation of the method showed adequate linearity (r²=0.9995), precision (R.S.D. = 4.0% for intra-day and 4.5% for inter-day precision) and accuracy (mean recovery = 102.9%). High performance liquid chromatography was chosen as a comparison method for the fluconazole determination. The contents of fluconazole determined by both methods, for four capsule samples, showed a strong correlation, confirmed by Pearson's correlation coefficient value (r = 0.9884). The bioassay is a suitable method for both research and pharmaceutical industry laboratories.Este trabalho visou ao desenvolvimento e validação de um método microbiológico por difusão em ágar para quantificação de fluconazol em cápsulas utilizando o isolado Candida albicans ATCC 18804 como reagente biológico. O método foi validado e foi verificada linearidade (r²=0,9995), precisão (D.P.R. = 4.0% para precisão intra-dia e 4,5% para precisão inter-dia) e exatidão (recuperação média = 102,9%). Concomitantemente, foi realizado o doseamento de fluconazol nas cápsulas por meio de cromatografia líquida de alta eficiência. Os teores encontrados por ambos os métodos demonstraram alta correlação, confirmada pelo Coeficiente de Correlação de Pearson (r = 0,9884). O ensaio microbiológico desenvolvido pode ser considerado ferramenta valiosa tanto para a pesquisa científica quanto para a rotina da indústria farmacêutica

    Determinação da glibenclamida por espectrofotometria derivada no ultravioleta para avaliação do teste ou perfil de dissolução de comprimidos

    Get PDF
    Glibenclamide (GLIB) or glyburide, a second-generation oral hypoglycemic drug, is used in the tablet form for the treatment of diabetes mellitus. Because of the low aqueous solubility of this sulfonylurea, a low drug release in the dissolution test may occur, hence, causing variabilility in the treatment. GLIB methanolic solution shows UV absorption maxima in lambda 210 nm, 227.5 nm and 300 nm. After released from tablets in the dissolution test, its spectrophotometric determination is difficult due to the low drug concentration in solution (5 mg GLIB tablets, medium volume 900 mL, 0.56 mg%). In addition, it presents a low absorption in the characteristic wavelength of lambda 300 nm. Up to date, there is no method recommendation for GLIB determination in tablet monographs in many of national or foreign official compendia. For this reason, the dissolution test performance lacks uniformity by official recommended procedures, to prove pharmaceutical equivalence to the reference drug, for generic candidates. GLIB spectrophotometric determination is investigated by first and second derivative orders (peaks at lambda 238 nm and 218 nm, respectively in 0.1 mol L-1 phosphate buffer solution) using reference and test tablets containing 5 mg of GLIB per unit dose.A glibenclamida (GLIB) ou gliburida, agente hipoglicemiante oral de segunda geração, da classe das sulfoniluréias, é usada sob a forma de comprimidos para controle do diabetes mellitus. Possui baixa solubilidade aquosa, podendo proporcionar baixa liberação no teste de dissolução de comprimidos e acarretar variabilidades no tratamento. A solução metanólica de GLIB apresenta máximos de absorção em lambda 210 nm, 227,5 nm e 300 nm na região ultravioleta (UV). Após liberaçao de comprimidos, a sua determinação espectrofotométrica na região UV é dificultada devido à baixa concentração proporcionada após o teste de dissolução (comprimidos GLIB 5 mg, volume de meio 900 mL, 0,56 mg%) e à baixa absortividade em comprimento de onda característico, lambda 300 nm. Por estas razões, até hoje, não existe um método de análise proposto para o teste de dissolução em farmacopéias nacional ou estrangeiras para monografia de glibenclamida comprimidos. A falta de uniformidade nestes procedimentos onera a execução de testes de dissolução para verificação da equivalência farmacêutica de especialidades candidatas a genéricos. Este trabalho propõe a determinação espectrofotométrica de GLIB por derivada de primeira e segunda ordens (máximos lambda 238 nm e 218 nm, respectivamente, em tampão fosfato 0,1 mol L-1), utilizando comprimidos referência e teste contendo 5 mg de fármaco por dose unitária