11 research outputs found

    Nationwide practice and outcomes of endoscopic biliary drainage in resectable pancreatic head and periampullary cancer

    Get PDF
    BACKGROUND: Guidelines advise self-expanding metal stents (SEMS) over plastic stents in preoperative endoscopic biliary drainage (EBD) for malignant extrahepatic biliary obstruction. This study aims to assess nationwide practice and outcomes. METHODS: Patients with pancreatic head and periampullary cancer who underwent EBD before pancreatoduodenectomy were included from the Dutch Pancreatic Cancer Audit (2017-2018). Multivariable logistic and linear regression models were performed. RESULTS: In total, 575/1056 patients (62.0%) underwent preoperative EBD: 246 SEMS (42.8%) and 329 plastic stents (57.2%). EBD-related complications were comparable between the groups (44/246 (17.9%) vs. 64/329 (19.5%), p = 0.607), including pancreatitis (22/246 (8.9%) vs. 25/329 (7.6%), p = 0.387). EBD-related cholangitis was reduced after SEMS placement (10/246 (4.1%) vs. 32/329 (9.7%), p = 0.043), which was confirmed in multivariable analysis (OR 0.36 95%CI 0.15-0.87, p = 0.023). Major postoperative complications did not differ (58/246 (23.6%) vs. 90/329 (27.4%), p = 0.316), whereas postoperative pancreatic fistula (24/246 (9.8%) vs. 61/329 (18.5%), p = 0.004; OR 0.50 95%CI 0.27-0.94, p = 0.031) and hospital stay (14.0 days vs. 17.4 days, p = 0.005; B 2.86 95%CI -5.16 to -0.57, p = 0.014) were less after SEMS placement. CONCLUSION: This study found that preoperative EBD frequently involved plastic stents. SEMS seemed associated with lower risks of cholangitis and less postoperative pancreatic fistula, but without an increased pancreatitis risk

    Aerophagia:Excessive Air Swallowing Demonstrated by Esophageal Impedance Monitoring

    No full text
    BACKGROUND & AIMS: Patients with aerophagia suffer from the presence of an excessive volume of intestinal gas, which is thought to result from excessive air ingestion. However, this has not been shown thus far. The aim of this study was therefore to assess swallowing and air swallowing frequencies in patients with Suspected aerophagia. METHODS: Ambulatory 24-hour pH-impedance monitoring was performed in patients in whom excessive amounts of intestinal gas were visualized on plain abdominal radiograms. All patients had symptoms of bloating, abdominal distention, flatulence, or excessive belching. Reflux parameters and the number of swallows and air swallows were assessed. RESULTS: The most common symptoms were bloating, abdominal distention, and constipation. Only 3 patients reported excessive belching and 1 patient reported flatulence as their predominant symptom. During the 24-hour measurement, patients showed high incidences of air swallows (521 +/- 63) and gastric belches (126 +/- 37). Patients had normal swallowing frequency (741 +/- 71). CONCLUSIONS: This study presents objective parameters that confirm the existence of excessive air swallowing or aerophagia using esophageal impedance monitoring

    Esophageal acid exposure decreases intraluminal baseline impedance levels

    No full text
    Intraluminal baseline impedance levels are determined by the conductivity of the esophageal wall and can be decreased in gastroesophageal reflux disease (GERD) patients. The aim of this study was to investigate the baseline impedance in GERD patients, on and off proton pump inhibitor (PPI), and in healthy controls. Ambulatory 24-h pH-impedance monitoring was performed in (i) 24 GERD patients with and 24 without pathological esophageal acid exposure as well as in 10 healthy controls and in (ii) 20 patients with refractory GERD symptoms despite PPI, once on PPI and once off PPI. Baseline impedance levels in the most distal and the most proximal impedance channels were assessed. Median (interquartile range) distal baseline impedance in patients with physiological (2,090 (1,537-2,547) Ω) and pathological (781 (612-1,137) Ω) acid exposure was lower than in controls (2,827 (2,127-3,270) Ω, P <0.05 and P <0.001). A negative correlation between 24-h acid exposure time and baseline impedance was observed (r=-0.7, P <0.001). In patients measured off and on PPI, median distal baseline impedance off PPI was significantly lower than on PPI (886 (716-1,354) vs. 1,372 (961-1,955) Ω, P <0.05) and distal baseline impedance in these groups was significantly lower than in healthy controls (P <0.05 and P <0.001). Proximal baseline impedance did not differ significantly between the patients off PPI and on PPI (1,793 (1,384-2,489) vs. 1,893 (1,610-2,561) Ω); however, baseline impedance values in both measurements were significantly lower than in healthy controls (3,648 (2,815-3,932) Ω, both P <0.001). These findings suggest that baseline impedance is related to esophageal acid exposure and could be a marker of reflux-induced changes to the esophageal mucos

    Ambulatory oesophageal pH monitoring: a comparison between antimony, ISFET, and glass pH electrodes

    No full text
    BACKGROUND AND AIM: Ambulatory oesophageal pH-impedance monitoring is a widely used test to evaluate patients with reflux symptoms. Several types of pH electrodes are available: antimony, ion sensitive field effect transistor (ISFET), and glass electrodes. These pH electrodes have not been compared directly, and it is uncertain whether these different types of pH electrodes result in similar outcome. METHODS: In an in-vitro model the response time, sensitivity, and drift of an antimony, ISFET, and glass pH electrode were assessed simultaneously after calibration at 22 degrees C and at 37 degrees C. All measurements were performed at 37 degrees C and repeated five times with new catheters of each type. Fifteen patients with reflux symptoms underwent 24-h pH monitoring off PPI therapy using antimony, ISFET, and glass pH electrodes simultaneously. RESULTS: After calibration at 22 degrees C, pH electrodes had similar response times, sensitivity and drift. In contrast to glass electrodes, antimony electrodes performed less accurately after calibration at 37 degrees C than after calibration at 22 degrees C. Calibration temperature did not affect ISFET electrodes significantly. During in-vivo experiments, significant differences were found in acid exposure times derived from antimony (4.0+/-0.8%), ISFET (5.7+/-1.1%), and glass pH electrodes (9.0+/-1.7%). CONCLUSION: In vitro, antimony and glass pH electrodes are affected by different buffer components and temperature, respectively. In vivo, significant higher acid exposure times are obtained with glass electrodes compared with antimony and ISFET pH electrodes. ISFET electrodes produce stable in-vitro measurements and result in the most accurate in-vivo measurements of acid exposure tim

    Computer analysis of 24-h esophageal impedance signals

    No full text
    To assess the accuracy of newly developed software for detection of gastro-esophageal reflux episodes in ambulatory 24-h impedance tracings. MATERIAL AND METHODS. 24-h esophageal impedance recordings obtained from 60 consecutive patients with reflux symptoms were used in this study. The impedance tracings of the first 10 consecutive patients were analyzed manually by three investigators. Liquid-containing reflux episodes and their proximal extent were scored. A consensus between the three investigators was used as a gold standard. Computer analysis using dedicated software was performed, and the results were compared with the results of the consensus agreement. In addition, in order to assess the accuracy of symptom association analysis 24-h impedance tracings of all 60 patients were analyzed both manually by one investigator and using computer software. The number of reflux episodes and the results of symptom association analysis obtained by the human and computer analysis software were compared. The consensus meeting resulted in a total of 625 reflux episodes. The mean sensitivity and the percentage of true-positives of analysis by individual investigators was 89±1% and 94±1%, respectively. Automated analysis had a sensitivity of 73±4% and a proportion of true-positive reflux episodes of 62±8%. Symptom association analysis performed by the computer and a human observer showed concordant results in 83% of the patients. Although not as good as manual analysis by experts, computer analysis can be a helpful tool to identify reflux episodes and to assess the relationship between reflux episodes and symptom

    Esophageal pH-Impedance Monitoring in Patients With Therapy-Resistant Reflux Symptoms:'On' or 'Off' Proton Pump Inhibitor?

    No full text
    BACKGROUND: In patients with proton pump inhibitor (PPI)-resistant symptoms, ambulatory 24-h pH-impedance monitoring can be used to assess whether a relationship exists between symptoms and reflux episodes. Until now, it is unclear whether combined pH-impedance monitoring in these patients should be performed on or off PPI. METHODS: Thirty patients with symptoms of heartburn, chest pain, and/or regurgitation despite PPI twice daily underwent ambulatory 24-h pH-impedance monitoring twice, once on PPI and once after cessation of the PPI for 7 days. The order of the measurements was randomized. Reflux episodes were identified and classified as acid, weakly acidic, or weakly alkaline reflux. In addition, the symptom association probability (SAP) was calculated for each measurement. RESULTS: The total number of reflux episodes and proximal extent were not affected by PPI therapy. On PPI, there were fewer acid reflux episodes (49 +/- 34 off PPI vs 20 +/- 25 on PPI) while more weakly acidic reflux episodes were identified (24 +/- 17 off PPI vs 48 +/- 31 on PPI). Symptom association analysis identified 15 and 11 patients with a positive SAP in the measurement off and on PPI, respectively, the difference in yield of the SAP not being statistically significant. Eight of the 19 patients who had no symptoms or a negative SAP during measurement on PPI had a positive SAP off PPI therapy. In contrast, only 4 patients with a positive SAP on PPI were missed in the measurement off PPI therapy. CONCLUSIONS: In order to demonstrate or exclude GERD in patients with PPI-resistant symptoms, ambulatory 24-h pH-impedance monitoring should preferably be performed after cessation of PPI therapy because this approach seems to offer the best chance to assess a relationship between symptoms and reflux episode

    Esophageal motility and impedance characteristics in patients with Barrett's esophagus before and after radiofrequency ablation

    No full text
    Radiofrequency ablation (RFA) is a valuable treatment option in Barrett's esophagus resulting in eradication of dysplasia and conversion of all Barrett's epithelium into normal squamous epithelium. In Barrett's esophagus, esophageal impedance monitoring is hampered by low baseline impedance values. Whether these low baselines are caused by an intrinsically low impedance of cylindrical epithelium or by the excessive reflux itself is hitherto unknown. Data on esophageal motility after RFA are scarce. Our aim was to examine the effect of RFA on esophageal motility and esophageal baseline impedance in patients with Barrett's esophagus. In 10 patients, conventional esophageal manometry and 24-h pH-impedance measurements were performed before and after RFA. The number and type of reflux episodes were assessed and baseline impedance values were measured in all recording segments. In another five patients, high-resolution manometry was performed before and after RFA. Complete regression of all Barrett's epithelium was achieved in all 15 patients after 3 ± 1 RFA sessions. Overall, no significant motility changes were found after RFA. Patients had excessive acid exposure times before and after RFA [25 (17-42) and 16 (9-24)%, respectively]. Baseline esophageal impedance values were low, with the lowest values in the distal recording segments. RFA increased baseline impedance in all recording segments in the upright position; in the supine position, the effect just failed to reach statistically significant levels. RFA did not alter esophageal motility significantly. Low esophageal baseline impedance levels in patients with Barrett's esophagus reflect, at least in part, intrinsic impedance properties of cylindrical epithelium, as baselines increased after conversion into neosquamous epitheliu
    corecore