25 research outputs found

    The hybrid brain-computer interface: a bridge to assistive technology?

    Get PDF
    Dieser Beitrag ist mit Zustimmung des Rechteinhabers aufgrund einer (DFG geförderten) Allianz- bzw. Nationallizenz frei zugänglich.This publication is with permission of the rights owner freely accessible due to an Alliance licence and a national licence (funded by the DFG, German Research Foundation) respectively.Brain-Computer Interfaces (BCIs) can be extended by other input signals to form a so-called hybrid BCI (hBCI). Such an hBCI allows the processing of several input signals with at least one brain signal for control purposes, i.e. communication and environmental control. This work shows the principle, technology and application of hBCIs and discusses future objectives.EC/FP7/224631/EU/Tools for Brain-Computer Interaction/TOBIEC/FP7/288566/EU/Brain-neural computer interfaces on track to home – Development of a practical generation of BNCI for independent home use/BackHom

    The hybrid Brain-Computer Interface: a bridge to assistive technology?

    Get PDF
    Brain-Computer Interfaces (BCIs) can be extended by other input signals to form a so-called hybrid BCI (hBCI). Such an hBCI allows the processing of several input signals with at least one brain signal for control purposes, i.e. communication and environmental control. This work shows the principle, technology and application of hBCIs and discusses future objectives

    Tools for Brain-Computer Interaction: A General Concept for a Hybrid BCI

    Get PDF
    The aim of this work is to present the development of a hybrid Brain-Computer Interface (hBCI) which combines existing input devices with a BCI. Thereby, the BCI should be available if the user wishes to extend the types of inputs available to an assistive technology system, but the user can also choose not to use the BCI at all; the BCI is active in the background. The hBCI might decide on the one hand which input channel(s) offer the most reliable signal(s) and switch between input channels to improve information transfer rate, usability, or other factors, or on the other hand fuse various input channels. One major goal therefore is to bring the BCI technology to a level where it can be used in a maximum number of scenarios in a simple way. To achieve this, it is of great importance that the hBCI is able to operate reliably for long periods, recognizing and adapting to changes as it does so. This goal is only possible if many different subsystems in the hBCI can work together. Since one research institute alone cannot provide such different functionality, collaboration between institutes is necessary. To allow for such a collaboration, a new concept and common software framework is introduced. It consists of four interfaces connecting the classical BCI modules: signal acquisition, preprocessing, feature extraction, classification, and the application. But it provides also the concept of fusion and shared control. In a proof of concept, the functionality of the proposed system was demonstrated

    Review of the BCI Competition IV

    Get PDF
    The BCI competition IV stands in the tradition of prior BCI competitions that aim to provide high quality neuroscientific data for open access to the scientific community. As experienced already in prior competitions not only scientists from the narrow field of BCI compete, but scholars with a broad variety of backgrounds and nationalities. They include high specialists as well as students. The goals of all BCI competitions have always been to challenge with respect to novel paradigms and complex data. We report on the following challenges: (1) asynchronous data, (2) synthetic, (3) multi-class continuous data, (4) session-to-session transfer, (5) directionally modulated MEG, (6) finger movements recorded by ECoG. As after past competitions, our hope is that winning entries may enhance the analysis methods of future BCIs.BMBF, 01IB001A, LOKI - Lernen zur Organisation komplexer Systeme der Informationsverarbeitung - Lernen im Kontext der SzenenanalyseBMBF, 01GQ0850, Bernstein Fokus Neurotechnologie - Nichtinvasive Neurotechnologie für Mensch-Maschine InteraktionEC/FP7/224631/EU/Tools for Brain-Computer Interaction/TOBIEC/FP7/216886/EU/Pattern Analysis, Statistical Modelling and Computational Learning 2/PASCAL2BMBF, 01GQ0420, Verbundprojekt: Bernstein-Zentrum für Neural Dynamics, Freiburg - CNDFBMBF, 01GQ0761, Bewegungsassoziierte Aktivierung - Dekodierung bewegungsassoziierter GehirnsignaleBMBF, 01GQ0762, Bewegungsassoziierte Aktivierung - Gehirn- und Maschinenlerne

    Bayesian and frequentist analysis of an Austrian genome-wide association study of colorectal cancer and advanced adenomas

    Get PDF
    Most genome-wide association studies (GWAS) were analyzed using single marker tests in combination with stringent correction procedures for multiple testing. Thus, a substantial proportion of associated single nucleotide polymorphisms (SNPs) remained undetected and may account for missing heritability in complex traits. Model selection procedures present a powerful alternative to identify associated SNPs in high-dimensional settings. In this GWAS including 1060 colorectal cancer cases, 689 cases of advanced colorectal adenomas and 4367 controls we pursued a dual approach to investigate genome-wide associations with disease risk applying both, single marker analysis and model selection based on the modified Bayesian information criterion, mBIC2, implemented in the software package MOSGWA. For different case-control comparisons, we report models including between 1-14 candidate SNPs. A genome-wide significant association of rs17659990 (P=5.43x10(-9), DOCK3, chromosome 3p21.2) with colorectal cancer risk was observed. Furthermore, 56 SNPs known to influence susceptibility to colorectal cancer and advanced adenoma were tested in a hypothesis-driven approach and several of them were found to be relevant in our Austrian cohort. After correction for multiple testing (alpha=8.9x10(-4)), the most significant associations were observed for SNPs rs10505477 (P=6.08x10(-4)) and rs6983267 (P=7.35x10(-4)) of CASC8, rs3802842 (P=8.98x10(-5), COLCA1,2), and rs12953717 (P=4.64x10(-4), SMAD7). All previously unreported SNPs demand replication in additional samples. Reanalysis of existing GWAS datasets using model selection as tool to detect SNPs associated with a complex trait may present a promising resource to identify further genetic risk variants not only for colorectal cancer

    Watching object related movements modulates mirror-like activity in parietal brain regions

    No full text
    Objective: We studied the activation of cortical motor and parietal areas during the observation of object related grasping movements. By manipulating the type of an object (realistic versus abstract) and the type of grasping (correct versus incorrect), we addressed the question how observing such object related movements influences cortical rhythmicity, especially the mu-rhythm, in the context of an ‘‘extended’’ human mirror neuron system (MNS). Methods: Multichannel electroencephalogram (EEG) was recorded during the observation of different object-related grasping actions in twenty healthy subjects. Different movies were presented, showing sequences of correct or incorrect hand grasping actions related to an abstract or realistic (daily life) object. Results: Event-related de/synchronization (ERD/ERS) analyses revealed a larger ERD in the upper alpha (10–12 Hz), beta (16–20 Hz) and gamma (36–40 Hz) frequency bands over parietal brain regions depending on the type of grasping. The type of object only influenced ERD patterns in the gamma band range (36–40 Hz) at parietal sites suggesting a strong relation of gamma band activity and cortical object representation. Abstract and realistic objects produced lower beta band synchronization at central sites only, whereas depending on the type of grasping an ERS in the upper alpha band (10–12 Hz) was observed. Conclusion: Depending on the type of the grasped object and the type of grasping stronger parietal cortical activation occurred during movement observation. Significance: Discussing the results in terms of an ‘‘extended’’ human mirror neuron system (MNS), it could be concluded that beside sensorimotor areas a stronger involvement of parietal brain regions was found depending on the type of object and grasping movement observed

    Self-Paced (Asynchronous) BCI Control of a Wheelchair in Virtual Environments: A Case Study with a Tetraplegic

    Get PDF
    The aim of the present study was to demonstrate for the first time that brain waves can be used by a tetraplegic to control movements of his wheelchair in virtual reality (VR). In this case study, the spinal cord injured (SCI) subject was able to generate bursts of beta oscillations in the electroencephalogram (EEG) by imagination of movements of his paralyzed feet. These beta oscillations were used for a self-paced (asynchronous) brain-computer interface (BCI) control based on a single bipolar EEG recording. The subject was placed inside a virtual street populated with avatars. The task was to “go” from avatar to avatar towards the end of the street, but to stop at each avatar and talk to them. In average, the participant was able to successfully perform this asynchronous experiment with a performance of 90%, single runs up to 100%

    TiD - Introducing and Benchmarking an Event-Delivery System for Brain-Computer Interfaces

    No full text
    In this paper, we present and analyze an event distribution system for brain-computer interfaces. Events are commonly used to mark and describe incidents during an experiment and are therefore critical for later data analysis or immediate real-time processing. The presented approach, called Tools for brain-computer interaction interface D (TiD), delivers messages in XML format via a buslike system using transmission control protocol connections or shared memory. A dedicated server dispatches TiD messages to distributed or local clients. The TiD message is designed to be flexible and contains time stamps for event synchronization, whereas events describe incidents, which occur during an experiment. TiD was tested extensively toward stability and latency. The effect of an occurring event jitter was analyzed and benchmarked on a reference implementation under different conditions as gigabit and 100-Mb Ethernet or Wi-Fi with a different number of event receivers. A 3-dB signal attenuation, which occurs when averaging jitter influenced trials aligned by events, is starting to become visible at around 1-2 kHz in the case of a gigabit connection. Mean event distribution times across operating systems are ranging from 0.3 to 0.5ms for a gigabit network connection for 10 6 events. Results for other environmental conditions are available in this paper. References already using TiD for event distribution are provided showing the applicability of TiD for event delivery with distributed or local clients
    corecore