3 research outputs found

    Prognostic clinical and radiological parameters for immediate facial nerve function following vestibular schwannoma surgery

    Get PDF
    OBJECTIVE: The paper aims to define the parameters available before surgery which could predict immediate facial nerve function after excision of a vestibular schwannoma (VS). METHODS: Ninety-nine patients with VS operated consecutively by a single surgeon using an identical surgical technique have been evaluated retrospectively. Data were collected regarding patients' sex, age at onset of symptoms and at surgery, initial symptoms, neurological status at presentation, early post-operative neurological status and complications. The main radiological parameters included in the study were tumour extension pattern, diameters, shape, and volume, as well as extent of bony changes of the internal auditory canal. RESULTS: As the tumour stage and volume increase, facial nerve function is worse after surgery (p < 0.001 and p < 0.05, respectively). Concomitantly, larger extra-meatal tumour diameters in three dimensions (sagittal, coronal and axial) led to worse function (p < 0.01). Anterior and/or caudal tumour extension (p = 0.001 and p = 0.004, respectively) had more significant correlation than posterior and/or cranial extension (p = 0.022 and p = 0.353, respectively). Polycyclic VS had the worst prognosis, followed by the tumours with oval shape. The extent of intra-meatal tumour growth does not correlate with immediate facial nerve outcome. The different angles, lengths and diameters of the internal auditory channel showed no significant correlation with facial nerve outcome. Patients with headache as an initial symptom and those with gait instability and/or pre-operative poor facial nerve function had significantly worse immediate facial nerve outcome. CONCLUSION: Our data suggests that the analysis of the radiological and neurological patient data prior to surgery could give reliable clues regarding the immediate post-operative facial nerve function

    Reliability of intraoperative high-resolution 2D ultrasound as an alternative to high-field strength MR imaging for tumor resection control: a prospective comparative study

    No full text
    OBJECT: Ultrasound may be a reliable but simpler alternative to intraoperative MR imaging (iMR imaging) for tumor resection control. However, its reliability in the detection of tumor remnants has not been definitely proven. The aim of the study was to compare high-field iMR imaging (1.5 T) and high-resolution 2D ultrasound in terms of tumor resection control. METHODS: A prospective comparative study of 26 consecutive patients was performed. The following parameters were compared: the existence of tumor remnants after presumed radical removal and the quality of the images. Tumor remnants were categorized as: detectable with both imaging modalities or visible only with 1 modality. RESULTS: Tumor remnants were detected in 21 cases (80.8%) with iMR imaging. All large remnants were demonstrated with both modalities, and their image quality was good. Two-dimensional ultrasound was not as effective in detecting remnants<1 cm. Two remnants detected with iMR imaging were missed by ultrasound. In 2 cases suspicious signals visible only on ultrasound images were misinterpreted as remnants but turned out to be a blood clot and peritumoral parenchyma. The average time for acquisition of an ultrasound image was 2 minutes, whereas that for an iMR image was approximately 10 minutes. Neither modality resulted in any procedure-related complications or morbidity. CONCLUSIONS: Intraoperative MR imaging is more precise in detecting small tumor remnants than 2D ultrasound. Nevertheless, the latter may be used as a less expensive and less time-consuming alternative that provides almost real-time feedback information. Its accuracy is highest in case of more confined, deeply located remnants. In cases of more superficially located remnants, its role is more limited
    corecore