21 research outputs found

    Natriuretic peptides and integrated risk assessment for cardiovascular disease: an individual-participant-data meta-analysis

    Get PDF
    BACKGROUND: Guidelines for primary prevention of cardiovascular diseases focus on prediction of coronary heart disease and stroke. We assessed whether or not measurement of N-terminal-pro-B-type natriuretic peptide (NT-proBNP) concentration could enable a more integrated approach than at present by predicting heart failure and enhancing coronary heart disease and stroke risk assessment. METHODS: In this individual-participant-data meta-analysis, we generated and harmonised individual-participant data from relevant prospective studies via both de-novo NT-proBNP concentration measurement of stored samples and collection of data from studies identified through a systematic search of the literature (PubMed, Scientific Citation Index Expanded, and Embase) for articles published up to Sept 4, 2014, using search terms related to natriuretic peptide family members and the primary outcomes, with no language restrictions. We calculated risk ratios and measures of risk discrimination and reclassification across predicted 10 year risk categories (ie, <5%, 5% to <7·5%, and ≥7·5%), adding assessment of NT-proBNP concentration to that of conventional risk factors (ie, age, sex, smoking status, systolic blood pressure, history of diabetes, and total and HDL cholesterol concentrations). Primary outcomes were the combination of coronary heart disease and stroke, and the combination of coronary heart disease, stroke, and heart failure. FINDINGS: We recorded 5500 coronary heart disease, 4002 stroke, and 2212 heart failure outcomes among 95 617 participants without a history of cardiovascular disease in 40 prospective studies. Risk ratios (for a comparison of the top third vs bottom third of NT-proBNP concentrations, adjusted for conventional risk factors) were 1·76 (95% CI 1·56-1·98) for the combination of coronary heart disease and stroke and 2·00 (1·77-2·26) for the combination of coronary heart disease, stroke, and heart failure. Addition of information about NT-proBNP concentration to a model containing conventional risk factors was associated with a C-index increase of 0·012 (0·010-0·014) and a net reclassification improvement of 0·027 (0·019-0·036) for the combination of coronary heart disease and stroke and a C-index increase of 0·019 (0·016-0·022) and a net reclassification improvement of 0·028 (0·019-0·038) for the combination of coronary heart disease, stroke, and heart failure. INTERPRETATION: In people without baseline cardiovascular disease, NT-proBNP concentration assessment strongly predicted first-onset heart failure and augmented coronary heart disease and stroke prediction, suggesting that NT-proBNP concentration assessment could be used to integrate heart failure into cardiovascular disease primary prevention. FUNDING: British Heart Foundation, Austrian Science Fund, UK Medical Research Council, National Institute for Health Research, European Research Council, and European Commission Framework Programme 7

    Impact of de novo donor-specific HLA antibodies detected by Luminex solid-phase assay after transplantation in a group of 88 consecutive living-donor renal transplantations

    No full text
    De novo donor-specific HLA antibodies (DSA) after renal transplantation are known to be correlated with poor graft outcome and the development of acute and chronic rejection. Currently, data for the influence of de novo DSA in patient cohorts including only living-donor renal transplantations (LDRT) are limited. A consecutive cohort of 88 LDRT was tested for the occurrence of de novo DSA by utilizing the highly sensitive Luminex solid-phase assay for antibody detection. Data were analyzed for risk factors for de novo DSA development and correlated with acute rejection (AR) and graft function. Patients with de novo DSA [31 (35%)] showed a trend for inferior graft function [mean creatinine change (mg/dL/year) after the first year: 0.15 DSA (+) vs. 0.02 DSA (-) (P=0.10)] and a higher rate of AR episodes, especially in case of de novo DSA of both class I and II [6 (55%), (P=0.05)]. Antibody-mediated rejection (AMR) appeared in five patients and was significantly correlated with de novo DSA (P=0.05). Monitoring for de novo DSA after LDRT may help to identify patients at risk of declining renal function. Especially patients with simultaneous presence of de novo DSA class I and class II are at a high risk to suffer AR episodes

    Optimizing a living kidney donation program: transition to hand-assisted retroperitoneoscopic living donor nephrectomy and introduction of a passive polarizing three-dimensional display system

    No full text
    Optimizing a living kidney donation program is important to guarantee a high grade of acceptance among potential donors. Hand-assisted retroperitoneoscopic donor nephrectomy (HARP) is an alternative to the open anterior approach (AA) technique. Problems associated to the learning curve could hinder a transition. 3D display technique seems to ease minimally invasive surgery. Aim of this study was to evaluate the learning curve during the transition from AA to HARP and the influence of the 3D display system on the established technique. Observational study (n = 207) during transition to HARP and introduction of 3D display technique. Operation time (OT), warm ischemia time (WIT) and blood loss (BL) of HARP decreased during transition. Pairwise group comparison for OT showed a significant learning effect for the first 30 out of 50 HARPs without influence on graft function. Between AA and HARP no significant difference in OT (133 +/- 24 vs. 127 +/- 19 min, p = 0.25) but for WIT (23 +/- 28 vs. 126 +/- 40 s, p < 0.005) and BL (328 +/- 207 vs. 54 +/- 35 ml, p < 0.005) was seen. There was neither a significant difference in donors' nor recipients' eGFR. OT (98 +/- 16 vs. 106 +/- 19 min, p = 0.036) and WIT (97 +/- 37 vs. 120 +/- 57 s, p = 0.023) were significantly shorter for the 3D technique compared to 2D. A transition to HARP is possible without additional risk for the donor or loss of quality for the recipient. The learning curve for HARP is steep and short. The introduction of 3D display technique after transition facilitates the surgical preparation and could further help to optimize HARP

    True single-port cholecystectomy with ICG cholangiography through a single 15-mm trocar using the new surgical platform symphonX: first human case study with a commercially available device

    No full text
    Background Minimally invasive single-port surgery is often associated with large incisions up to 2-3 cm, complicated handling due to the lack of triangulation, and instrument crossing. Aim of this prospective study was to perform true single-port surgery (cholecystectomy) without the use of assisting trocars using a new surgical platform that allows for triangulation incorporating robotic features, and to measure the perioperative outcome and cosmetic results. Methods As the first European site after FDA and CE-mark approval, the new device has been introduced to our academic center. In patients with cholecystitis and cholecystolithiasis, the operation was performed through only one 15-mm trocar. For patients safety, intraoperative cholangiography using intravenous ICG and a standard Stryker 1588 system was routinely performed. Results Symphonx was used in n = 12 patients for abdominal surgery (6 females, mean age 42.5 [30-77], mean BMI 26.2 [19.3-38.9]. A total of 8 patients underwent surgery using no additional ports besides the 15-mm trocar; in the remaining patients, one assisting instrument (3-5 mm) was used. Mean OR time was 107 [72-221] minutes. The postoperative course was uneventful in 11 patients; in one patient, a seroma at the surgical site required interventional drainage 1 month postoperatively. No intraoperative complications occurred. Conclusion This is the first human case series using the commercially available symphonX platform for abdominal laparoscopic surgery and the first series using the system without assisting instruments. Laparoscopic cholecystectomy in patients with cholecystitis and cholecystolithiasis using the symphonX platform through only one 15-mm trocar is feasible, safe, and more cost-efficient compared to robotic platforms
    corecore