3 research outputs found
A Bubble-Free Microfluidic Device for Easy-to-Operate Immobilization, Culturing and Monitoring of Zebrafish Embryos
The development of miniaturized devices for studying zebrafish embryos has been limited due to complicated fabrication and operation processes. Here, we reported on a microfluidic device that enabled the capture and culture of zebrafish embryos and real-time monitoring of dynamic embryonic development. The device was simply fabricated by bonding two layers of polydimethylsiloxane (PDMS) structures replicated from three-dimensional (3D) printed reusable molds onto a flat glass substrate. Embryos were easily loaded into the device with a pipette, docked in traps by gravity, and then retained in traps with hydrodynamic forces for long-term culturing. A degassing chamber bonded on top was used to remove air bubbles from the embryo-culturing channel and traps so that any embryo movement caused by air bubbles was eliminated during live imaging. Computational fluid dynamics simulations suggested this embryo-trapping and -retention regime to exert low shear stress on the immobilized embryos. Monitoring of the zebrafish embryogenesis over 20 h during the early stages successfully verified the performance of the microfluidic device for culturing the immobilized zebrafish embryos. Therefore, this rapid-prototyping, low-cost and easy-to-operate microfluidic device offers a promising platform for the long-term culturing of immobilized zebrafish embryos under continuous medium perfusion and the high-quality screening of the developmental dynamics
A Wide-Band Digital Lock-In Amplifier and Its Application in Microfluidic Impedance Measurement
In this work, we report on the design of a wide-band digital lock-in amplifier (DLIA) of up to 65 MHz and its application for electrical impedance measurements in microfluidic devices. The DLIA is comprised of several dedicated technologies. First, it features a fully differential analog circuit, which includes a preamplifier with a low input noise of 4.4 nV/root Hz, a programmable-gain amplifier with a gain of 52 dB, and an anti-aliasing, fully differential low-pass filter with -76 dB stop-band attenuation. Second, the DLIA has an all-digital phase lock loop, which features a phase deviation of less than 0.02 degrees throughout the frequency range. The phase lock loop utilizes an equally accurate period-frequency measurement, with a sub-ppm precision of frequency detection. Third, a modified clock link is implemented in the DLIA to improve the signal-to-noise ratio of the analog-to-digital converter affected by clock jitter of up to 20 dBc. A series of measurements were performed to characterize the DLIA, and the results showed an accurate performance. Additionally, impedance measurements of standard-size microparticles were performed by frequency sweep from 300 kHz to 30 MHz, using the DLIA in a microfluidic device. Different diameters of microparticle could be accurately distinguished according to the relative impedance at 2.5 MHz. The results confirm the promising applications of the DLIA in microfluidic electrical impedance measurements