658 research outputs found
The effects of star formation on the low-metallicity ISM: NGC4214 mapped with Herschel/PACS spectroscopy
We present Herschel/PACS spectroscopic maps of the dwarf galaxy NC4214
observed in 6 far infrared fine-structure lines: [C II] 158mu, [O III] 88mu, [O
I] 63mu, [O I] 146mu, [N II] 122mu, and [N II] 205mu. The maps are sampled to
the full telescope spatial resolution and reveal unprecedented detail on ~ 150
pc size scales. We detect [C II] emission over the whole mapped area, [O III]
being the most luminous FIR line. The ratio of [O III]/[C II] peaks at about 2
toward the sites of massive star formation, higher than ratios seen in dusty
starburst galaxies. The [C II]/CO ratios are 20 000 to 70 000 toward the 2
massive clusters, which are at least an order of magnitude larger than spiral
or dusty starbursts, and cannot be reconciled with single-slab PDR models.
Toward the 2 massive star-forming regions, we find that L[CII] is 0.5 to 0.8%
of the LTIR . All of the lines together contribute up to 2% of LTIR . These
extreme findings are a consequence of the lower metallicity and young,
massive-star formation commonly found in dwarf galaxies. These conditions
promote large-scale photodissociation into the molecular reservoir, which is
evident in the FIR line ratios. This illustrates the necessity to move to
multiphase models applicable to star-forming clusters or galaxies as a whole.Comment: Accepted for publication in the A&A Herschel Special Issu
Star Formation in M51 Triggered by Galaxy Interaction
We have mapped the inner 360'' regions of M51 in the 158micron [CII] line at
55'' spatial resolution using the Far-infrared Imaging Fabry-Perot
Interferometer (FIFI) on the Kuiper Airborne Observatory (KAO). The emission is
peaked at the nucleus, but is detectable over the entire region mapped, which
covers much of the optical disk of the galaxy. There are also two strong
secondary peaks at ~43% to 70% of the nuclear value located roughly 120'' to
the north-east, and south-west of the nucleus. These secondary peaks are at the
same distance from the nucleus as the corotation radius of the density wave
pattern. The density wave also terminates at this location, and the outlying
spiral structure is attributed to material clumping due to the interaction
between M51 and NGC5195. This orbit crowding results in cloud-cloud collisions,
stimulating star formation, that we see as enhanced [CII] line emission. The
[CII] emission at the peaks originates mainly from photodissociation regions
(PDRs) formed on the surfaces of molecular clouds that are exposed to OB
starlight, so that these [CII] peaks trace star formation peaks in M51. The
total mass of [CII] emitting photodissociated gas is ~2.6x10^{8} M_{sun}, or
about 2% of the molecular gas as estimated from its CO(1-0) line emission. At
the peak [CII] positions, the PDR gas mass to total gas mass fraction is
somewhat higher, 3-17%, and at the secondary peaks the mass fraction of the
[CII] emitting photodissociated gas can be as high as 72% of the molecular
mass.... (continued)Comment: 14 pages, 6 figures, Accepted in ApJ (for higher resolution figures
contact the author
Rapid and Precise Semi-Automatic Axon Quantification in Human Peripheral Nerves
We developed a time-efficient semi-automated axon quantification method using freeware in human cranial nerve sections stained with paraphenylenediamine (PPD). It was used to analyze a total of 1238 facial and masseteric nerve biopsies. The technique was validated by comparing manual and semi-automated quantification of 129 (10.4%) randomly selected biopsies. The software-based method demonstrated a sensitivity of 94% and a specificity of 87%. Semi-automatic axon counting was significantly faster (p<0.001) than manual counting. It took 1hour and 47minutes for all 129 biopsies (averaging 50sec per biopsy, 0.04seconds per axon). The counting process is automatic and does not need to be supervised. Manual counting took 21hours and 6minutes in total (average 9minutes and 49seconds per biopsy, 0.52seconds per axon). Our method showed a linear correlation to the manual counts (R=0.944 Spearman rho). Attempts have been made by several research groups to automate axonal load quantification. These methods often require specific hard- and software and are therefore only accessible to a few specialized laboratories. Our semi-automated axon quantification is precise, reliable and time-sparing using publicly available software and should be useful for an effective axon quantification in various human peripheral nerves
A 15.65 solar mass black hole in an eclipsing binary in the nearby spiral galaxy Messier 33
Stellar-mass black holes are discovered in X-ray emitting binary systems,
where their mass can be determined from the dynamics of their companion stars.
Models of stellar evolution have difficulty producing black holes in close
binaries with masses >10 solar masses, which is consistent with the fact that
the most massive stellar black holes known so all have masses within 1 sigma of
10 solar masses. Here we report a mass of 15.65 +/- 1.45 solar masses for the
black hole in the recently discovered system M33 X-7, which is located in the
nearby galaxy Messier 33 (M33) and is the only known black hole that is in an
eclipsing binary. In order to produce such a massive black hole, the progenitor
star must have retained much of its outer envelope until after helium fusion in
the core was completed. On the other hand, in order for the black hole to be in
its present 3.45 day orbit about its 70.0 +/- 6.9 solar mass companion, there
must have been a ``common envelope'' phase of evolution in which a significant
amount of mass was lost from the system. We find the common envelope phase
could not have occured in M33 X-7 unless the amount of mass lost from the
progenitor during its evolution was an order of magnitude less than what is
usually assumed in evolutionary models of massive stars.Comment: To appear in Nature October 18, 2007. Four figures (one color figure
degraded). Differs slightly from published version. Supplementary Information
follows in a separate postin
The Charge Form Factor of the Neutron at Low Momentum Transfer from the Reaction
We report new measurements of the neutron charge form factor at low momentum
transfer using quasielastic electrodisintegration of the deuteron.
Longitudinally polarized electrons at an energy of 850 MeV were scattered from
an isotopically pure, highly polarized deuterium gas target. The scattered
electrons and coincident neutrons were measured by the Bates Large Acceptance
Spectrometer Toroid (BLAST) detector. The neutron form factor ratio
was extracted from the beam-target vector asymmetry
at four-momentum transfers , 0.20, 0.29 and 0.42
(GeV/c).Comment: 5 pages, 3 figures, submitted to Phys. Rev. Let
Measurement of the proton electric to magnetic form factor ratio from \vec ^1H(\vec e, e'p)
We report the first precision measurement of the proton electric to magnetic
form factor ratio from spin-dependent elastic scattering of longitudinally
polarized electrons from a polarized hydrogen internal gas target. The
measurement was performed at the MIT-Bates South Hall Ring over a range of
four-momentum transfer squared from 0.15 to 0.65 (GeV/c).
Significantly improved results on the proton electric and magnetic form factors
are obtained in combination with previous cross-section data on elastic
electron-proton scattering in the same region.Comment: 4 pages, 2 figures, submitted to PR
The Photodetector Array Camera and Spectrometer (PACS) on the Herschel Space Observatory
The Photodetector Array Camera and Spectrometer (PACS) is one of the three
science instruments on ESA's far infrared and submillimetre observatory. It
employs two Ge:Ga photoconductor arrays (stressed and unstressed) with 16x25
pixels, each, and two filled silicon bolometer arrays with 16x32 and 32x64
pixels, respectively, to perform integral-field spectroscopy and imaging
photometry in the 60-210\mu\ m wavelength regime. In photometry mode, it
simultaneously images two bands, 60-85\mu\ m or 85-125\mu\m and 125-210\mu\ m,
over a field of view of ~1.75'x3.5', with close to Nyquist beam sampling in
each band. In spectroscopy mode, it images a field of 47"x47", resolved into
5x5 pixels, with an instantaneous spectral coverage of ~1500km/s and a spectral
resolution of ~175km/s. We summarise the design of the instrument, describe
observing modes, calibration, and data analysis methods, and present our
current assessment of the in-orbit performance of the instrument based on the
Performance Verification tests. PACS is fully operational, and the achieved
performance is close to or better than the pre-launch predictions
Search for Two-Neutrino Double Electron Capture of Xe with XENON100
Two-neutrino double electron capture is a rare nuclear decay where two
electrons are simultaneously captured from the atomic shell. For Xe
this process has not yet been observed and its detection would provide a new
reference for nuclear matrix element calculations. We have conducted a search
for two-neutrino double electron capture from the K-shell of Xe using
7636 kgd of data from the XENON100 dark matter detector. Using a
Bayesian analysis we observed no significant excess above background, leading
to a lower 90 % credibility limit on the half-life
yr. We also evaluated the sensitivity of the XENON1T experiment, which is
currently being commissioned, and find a sensitivity of
yr after an exposure of 2 tyr.Comment: 6 pages, 4 figure
- …