242 research outputs found

    A retrospective analysis of the clinical impact of 939 chest radiographs using the medical records.

    Get PDF
    Objective. Between one-third and half of all radiology examinations worldwide are probably chest studies. The aim of the current study was to retrospectively evaluate the clinical influence of chest radiography. Methods. In a tertiary referral hospital, 939 consecutive daytime chest radiography examinations were evaluated. The outcome was classified as normal, incidental, or pathologic. The referring physician's reaction to radiologic outcome was classified as highly expected, moderately expected, or unexpected. The influence on the patients' treatment was divided into four groups from major to no influence. Results. In all, 71.6% of the studies had a highly expected outcome. Moderately expected or unexpected outcomes were noted in 36.6% of 500 pathologic examinations. Unexpected outcome was noted in 11.6% of all studies. The radiologic outcome influenced treatment in 65.4% of patients where pathology was demonstrated. Patients with normal or incidental findings had treatment influenced in 1/3 of the cases. Unexpected findings influenced treatment more than moderately expected findings. When radiological findings were highly expected, treatment was influenced in less than half of the cases. Surprisingly few chest radiology examinations were commented upon in the medical records

    Comparison of the Commercial Color LCD and the Medical Monochrome LCD Using Randomized Object Test Patterns

    Get PDF
    Workstations and electronic display devices in a picture archiving and communication system (PACS) provide a convenient and efficient platform for medical diagnosis. The performance of display devices has to be verified to ensure that image quality is not degraded. In this study, we designed a set of randomized object test patterns (ROTPs) consisting of randomly located spheres with various image characteristics to evaluate the performance of a 2.5 mega-pixel (MP) commercial color LCD and a 3 MP diagnostic monochrome LCD in several aspects, including the contrast, resolution, point spread effect, and noise. The ROTPs were then merged into 120 abdominal CT images. Five radiologists were invited to review the CT images, and receiver operating characteristic (ROC) analysis was carried out using a five-point rating scale. In the high background patterns of ROTPs, the sensitivity performance was comparable between both monitors in terms of contrast and resolution, whereas, in the low background patterns, the performance of the commercial color LCD was significantly poorer than that of the diagnostic monochrome LCD in all aspects. The average area under the ROC curve (AUC) for reviewing abdominal CT images was 0.717±0.0200 and 0.740±0.0195 for the color monitor and the diagnostic monitor, respectively. The observation time (OT) was 145±27.6 min and 127±19.3 min, respectively. No significant differences appeared in AUC (p = 0.265) and OT (p = 0.07). The overall results indicate that ROTPs can be implemented as a quality control tool to evaluate the intrinsic characteristics of display devices. Although there is still a gap in technology between different types of LCDs, commercial color LCDs could replace diagnostic monochrome LCDs as a platform for reviewing abdominal CT images after monitor calibration

    Impact of Center Experience on Patient Radiation Exposure During Transradial Coronary Angiography and Percutaneous Intervention: A Patient-Level, International, Collaborative, Multi-Center Analysis.

    Get PDF
    BACKGROUND: The adoption of the transradial (TR) approach over the traditional transfemoral (TF) approach has been hampered by concerns of increased radiation exposure-a subject of considerable debate within the field. We performed a patient-level, multi-center analysis to definitively address the impact of TR access on radiation exposure. METHODS AND RESULTS: Overall, 10 centers were included from 6 countries-Canada (2 centers), United Kingdom (2), Germany (2), Sweden (2), Hungary (1), and The Netherlands (1). We compared the radiation exposure of TR versus TF access using measured dose-area product (DAP). To account for local variations in equipment and exposure, standardized TR:TF DAP ratios were constructed per center with procedures separated by coronary angiography (CA) and percutaneous coronary intervention (PCI). Among 57 326 procedures, we demonstrated increased radiation exposure with the TR versus TF approach, particularly in the CA cohort across all centers (weighted-average ratios: CA, 1.15; PCI, 1.05). However, this was mitigated by increasing TR experience in the PCI cohort across all centers (r=-0.8; P=0.005). Over time, as a center transitioned to increasing TR experience (r=0.9; P=0.001), a concomitant decrease in radiation exposure occurred (r=-0.8; P=0.006). Ultimately, when a center's balance of TR to TF procedures approaches 50%, the resultant radiation exposure was equivalent. CONCLUSIONS: The TR approach is associated with a modest increase in patient radiation exposure. However, this increase is eliminated when the TR and TF approaches are used with equal frequency-a guiding principle for centers adopting the TR approach

    Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures: A randomized study of 50 patients

    Get PDF
    Background and purpose In unstable distal radial fractures that are impossible to reduce or to maintain in reduced position, the treatment of choice is operation. The type of operation and the choice of implant, however, is a matter of discussion. Our aim was to investigate whether open reduction and internal fixation would produce a better result than traditional external fixation

    Electron Transfer from Cyt b559 and Tyrosine-D to the S2 and S3 states of the water oxidizing complex in Photosystem II at Cryogenic Temperatures

    Get PDF
    The Mn4CaO5 cluster of photosystem II (PSII) catalyzes the oxidation of water to molecular oxygen through the light-driven redox S-cycle. The water oxidizing complex (WOC) forms a triad with Tyrosine(Z) and P-680, which mediates electrons from water towards the acceptor side of PSII. Under certain conditions two other redox-active components, Tyrosine(D) (Y-D) and Cytochrome b (559) (Cyt b (559)) can also interact with the S-states. In the present work we investigate the electron transfer from Cyt b (559) and Y-D to the S-2 and S-3 states at 195 K. First, Y-D (aEuro cent) and Cyt b (559) were chemically reduced. The S-2 and S-3 states were then achieved by application of one or two laser flashes, respectively, on samples stabilized in the S-1 state. EPR signals of the WOC (the S-2-state multiline signal, ML-S-2), Y-D (aEuro cent) and oxidized Cyt b (559) were simultaneously detected during a prolonged dark incubation at 195 K. During 163 days of incubation a large fraction of the S-2 population decayed to S-1 in the S-2 samples by following a single exponential decay. Differently, S-3 samples showed an initial increase in the ML-S-2 intensity (due to S-3 to S-2 conversion) and a subsequent slow decay due to S-2 to S-1 conversion. In both cases, only a minor oxidation of Y-D was observed. In contrast, the signal intensity of the oxidized Cyt b (559) showed a two-fold increase in both the S-2 and S-3 samples. The electron donation from Cyt b (559) was much more efficient to the S-2 state than to the S-3 state

    A self-rating scale for patient-perceived side effects of inhaled corticosteroids

    Get PDF
    BACKGROUND: Patient-reported side effect questionnaires offer a simple method for the systematic measurement of drug-related side effects. In order to measure patients' inhaled corticosteroids (ICS) related side effect perceptions the 14-day retrospective Inhaled Corticosteroid Questionnaire (ICQ) was developed. In this research we aim to assess the construct validity and reliability of the ICQ and test its responsiveness to dose changes in adult asthma patients. METHODS: In a cross-sectional study, current inhaler users with asthma completed the ICQ (27 with non ICS inhaler; 61 BDP equivalent daily ICS low dose ≤400 μg; 62 mid dose 401–800 μg; and 105 with high dose >800 μg). We generated 3 construct validity hypotheses: 1) a hierarchical dose-response pattern for scoring of the individual items on the ICQ, and statistically significant differences in the scores of each of the 15 ICQ domains by ICS dose group 2) an association between ICS dose and ICQ scoring after adjusting for appropriate confounders in multiple regression; 3) greater convergence between local side effect domains than between systemic and local domains of the scale. Test-retest reliability was assessed on a randomly selected subgroup of patients (n = 73) who also completed the ICQ a second time after 7 days. In a separate longitudinal study, 61 patients with asthma completed the ICQ at baseline and after changing their daily ICS dose, at 2- and 6- months, in order to test the ICQ's responsiveness. RESULTS: All three construct validity hypotheses were well supported: 1) a statistically significant difference existed in scores for 14 domains, the high ICS dose group scoring highest; 2) ICS dose independently predicted ICQ scoring after adjusting for confounders; 3) greater convergence existed between local ICQ domains than between local and systemic domains. The ICQ had good reproducibility: test-retest intraclass correlation coefficients were ≥0.69 for all but the 'Facial Oedema' domain. In the longitudinal study, ICQ scores for 'Voice Problems' changed significantly at 2- and 6-months from baseline and other ICQ domains displayed trends in scoring change accordant with dose modulation at 6-months. CONCLUSION: The ICQ has good dose-related discriminative properties, is valid, reliable, and shows potential responsiveness to ICS dose change
    corecore