16,131 research outputs found

    Doppler measurements of the ionosphere on the occasion of the Apollo-Soyuz test project. Part 2: Inversion of differential and rotating Doppler shifts

    Get PDF
    The preparation of the analytical approach and of the related software used in the inversion of the differential and rotating Doppler data obtained from the ionospheric experiment of the Apollo-Soyuz Test Project (ASTP) is discussed. These data were collected in space-to-space paths (between the ASTP Docking Module (DM) and the Apollo Command Service Module and in space-to-ground paths (between the DM and ground). The Doppler links operated at 162 and 324 MHz and have an accuracy better than 3 MHz over 10-sec integration time. The inversion approach was tested with dummy data obtained with a computer simulation. It was found that a measurement accuracy of 1 to 10% in the value of the horizontal electron density gradient at 221-km altitude can be achieved, in space-to-space paths. For space-to-ground paths near the orbital plane, possible effects of the horizontal gradients on the received differential Doppler shifts were identified. It was possible to reduce the gradient-associated errors in the inversion that leads to the columnar electron content by approximately one-half. Accuracies of 5 to 10% in columnar electron content are achievable, with this gradient-compensation technique

    B Mixing

    Get PDF
    The neutral BB mesons, B0B^0 and BsB_s, can oscillate between their particle and antiparticle states owing to flavor-changing weak interactions. In recent years, techniques to detect these oscillations as a function of the meson's decay time have been developed. In this article the physics of flavor oscillations is reviewed and theoretical predictions are summarized. The many observations that demonstrate the time-dependence of B^0-\B0bar oscillations are presented along with a combined measurement of its frequency, δmd\delta m_d. The attempts to measure the BsB_s oscillation frequency, both directly and indirectly, are then summarized. Finally, values for the CKM elements Vtd|V_{td}| and Vts/Vtd|V_{ts}/V_{td}| are extracted

    Estimations for the Single Diffractive production of the Higgs boson at the Tevatron and the LHC

    Full text link
    The single diffractive production of the standard model Higgs boson is computed using the diffractive factorization formalism, taking into account a parametrization for the Pomeron structure function provided by the H1 Collaboration. We compute the cross sections at next-to-leading order accuracy for the gluon fusion process, which includes QCD and electroweak corrections. The gap survival probability () is also introduced to account for the rescattering corrections due to spectator particles present in the interaction, and to this end we compare two different models for the survival factor. The diffractive ratios are predicted for proton-proton collisions at the Tevatron and the LHC for the Higgs boson mass of MHM_H = 120 GeV. Therefore, our results provide updated estimations for the diffractive ratios of the single diffractive production of the Higgs boson in the Tevatron and LHC kinematical regimes.Comment: 20 pages, 6 figures, 3 table

    Dynamics of the peel front and the nature of acoustic emission during peeling of an adhesive tape

    Full text link
    We investigate the peel front dynamics and acoustic emission of an adhesive tape within the context of a recent model by including an additional dissipative energy that mimics bursts of acoustic signals. We find that the nature of the peeling front can vary from smooth to stuck-peeled configuration depending on the values of dissipation coefficient, inertia of the roller, mass of the tape. Interestingly, we find that the distribution of AE bursts shows a power law statistics with two scaling regimes with increasing pull velocity as observed in experiments. In this regimes, the stuck-peeled configuration is similar to the `edge of peeling' reminiscent of a system driven to a critical state.Comment: Accepted for publication in Phys. Rev. Let

    Implementing Session Centered Calculi

    Get PDF
    Recently, specific attention has been devoted to the development of service oriented process calculi. Besides the foundational aspects, it is also interesting to have prototype implementations for them in order to assess usability and to minimize the gap between theory and practice. Typically, these implementations are done in Java taking advantage of its mechanisms supporting network applications. However, most of the recurrent features of service oriented applications are re-implemented from scratch. In this paper we show how to implement a service oriented calculus, CaSPiS (Calculus of Services with Pipelines and Sessions) using the Java framework IMC, where recurrent mechanisms for network applications are already provided. By using the session oriented and pattern matching communication mechanisms provided by IMC, it is relatively simple to implement in Java all CaSPiS abstractions and thus to easily write the implementation in Java of a CaSPiS process

    Cavitation-induced force transition in confined viscous liquids under traction

    Full text link
    We perform traction experiments on simple liquids highly confined between parallel plates. At small separation rates, we observe a simple response corresponding to a convergent Poiseuille flow. Dramatic changes in the force response occur at high separation rates, with the appearance of a force plateau followed by an abrupt drop. By direct observation in the course of the experiment, we show that cavitation accounts for these features which are reminiscent of the utmost complex behavior of adhesive films under traction. Surprisingly enough, this is observed here in purely viscous fluids.Comment: Submitted to Physical Review Letters on May 31, 2002. Related informations on http://www.crpp.u-bordeaux.fr/tack.htm

    Preliminary hidrological results from Sarennes glacier basin, French Alps

    Get PDF
    Located in the French Alps, Glacier de Sarennes is a small glacier which has its mass balance, measured since 1948. Now since 1992, the Snow Engineenng and Avalanche control department of Cemagref Grenoble measures water leve1 in the emissary of this glacier at the altitude of 2800 meters. The time step of these records is 10 minutes. The aim of this study is to realize the first hydrological assessment, despite having few records until now, to be able to control the new experimental discharge station, and to extract the first scientific results

    Doppler measurements of the ionosphere on the occasion of the Apollo-Soyuz test project. Part 1: Computer simulation of ionospheric-induced Doppler shifts

    Get PDF
    A computer simulation of the ionospheric experiment of the Apollo-Soyuz Test Project (ASTP) was performed. ASTP is the first example of USA/USSR cooperation in space and is scheduled for summer 1975. The experiment consists of performing dual-frequency Doppler measurements (at 162 and 324 MHz) between the Apollo Command Service Module (CSM) and the ASTP Docking Module (DM), both orbiting at 221-km height and at a relative distance of 300 km. The computer simulation showed that, with the Doppler measurement resolution of approximately 3 mHz provided by the instrumentation (in 10-sec integration time), ionospheric-induced Doppler shifts will be measurable accurately at all times, with some rare exceptions occurring when the radio path crosses regions of minimum ionospheric density. The computer simulation evaluated the ability of the experiment to measure changes of columnar electron content between CSM and DM (from which horizontal gradients of electron density at 221-km height can be obtained) and to measure variations in DM-to-ground columnar content (from which an averaged columnar content and the electron density at the DM can be deduced, under some simplifying assumptions)

    Preliminary hidrological results from Sarennes glacier basin, French Alps

    Get PDF
    Located in the French Alps, Glacier de Sarennes is a small glacier which has its mass balance, measured since 1948. Now since 1992, the Snow Engineenng and Avalanche control department of Cemagref Grenoble measures water leve1 in the emissary of this glacier at the altitude of 2800 meters. The time step of these records is 10 minutes. The aim of this study is to realize the first hydrological assessment, despite having few records until now, to be able to control the new experimental discharge station, and to extract the first scientific results
    corecore