498 research outputs found

    Coupling early warning services, crowdsourcing, and modelling for improved decision support and wildfire emergency management

    Full text link
    The threat of a forest fire disaster increases around the globe as the human footprint continues to encroach on natural areas and climate change effects increase the potential of extreme weather. It is essential that the tools to educate, prepare, monitor, react, and fight natural fire disasters are available to emergency managers and responders and reduce the overall disaster effects. In the context of the I-REACT project, such a big crisis data system is being developed and is based on the integration of information from different sources, automated data processing chains and decision support systems. This paper presents the wildfire monitoring for emergency management system for those involved and affected by wildfire disasters developed for European forest fire disasters

    Characterization of Patients with Chronic Diseases and Complex Care Needs: A New High-Risk Emergent Population

    Get PDF
    Background: To analyze the prevalence and main epidemiological, clinical and outcome features of in-Patients with Complex Chronic conditions (PCC) in internal medicine areas, using a pragmatic working definition. Methods: Prospective study in 17 centers from Spain, with 97 in-hospital, monthly prevalence cuts. A PCC was considered when criteria of polypathological patient (two or more major chronic diseases) were met, or when a patient suffered one major chronic disease plus one or more of nine predefined complexity criteria like socio-familial risk, alcoholism or malnutrition among others (PCC without polypathology). A complete set of baseline features as well as 12-months survival were collected. Then, we compared clinical, outcome variables, and PROFUND index accuracy between polypathological patients and PCC without polypathology. Results: The global prevalence of PCC was 61% (40% of them were polypathological patients, and 21% PCC withouth polypathology) out of the 2178 evaluated patients. Their median age was 82 (59.5% men), suffered 2.3 ± 1.1 major diseases (heart diseases (70.5%), neurologic (41.5%), renal (36%), and lung diseases (26%)), 5.5 ± 2.5 other chronic conditions, met 2.5 ± 1.5 complexity criteria, and presented functional decline (Barthel index 55 (25-90)). Compared to polypathological patients, the subgroup of PCC without polypathology were younger, with a different pattern of major diseases and comorbidities, a better functional status, and lower 12-months mortality rates ((36.2% vs 46.8%; p = .003; OR 0.7(0.48-0.86). The PROFUND index obtained adequate calibration and discrimination power (AUC-ROC 0.67 (0.63-0.69)) in predicting 12-month mortality of PCC. Conclusion: Patients with complex chronic conditions are highly prevalent in internal medicine areas; their clinical pattern has changed in parallel to socio-epidemiological modifications, but their death-risk is still adequately predicted by PROFUND index

    Correlaciones entre la SPECT cerebral y la evaluación neuropsicológica en los estadios leve y moderado de la enfermedad de Alzheimer

    Get PDF
    Se evaluaron 34 pacientes con enfermedad de Alzheimer (EA) probable (EA leve = 16; EA moderada = 18) y 12 controles mediante un estudio semicuantitativo de SPECT con 99mTc-HMPAO y la batería de tests neuropsicológicos CERAD. Resultados: La hipoperfusión temporal (p < 0,01) y los tests de memoria (p < 0,001) permitieron diferenciar los controles de los pacientes con EA leve. En estos pacientes se observaron también correlaciones significativas (p < 0,05) entre: test de recuerdo diferido-hipoperfusión temporal, test de aprendizaje-hipoperfusión temporoparietal y frontal y praxis visuoconstructiva-hipoperfusión temporal posterior. Los pacientes con EA moderada mostraron, respecto a la EA leve, una mayor hipoperfusión temporal (p < 0,01), parietal y frontal (p < 0,05), junto a un empeoramiento de la praxis (p < 0,001) y los test de memoria (p < 0,05). Conclusiones: La SPECT y la evaluación neuropsicológica permiten distinguir entre controles y pacientes con estadios leve y moderado de la EA, existiendo una estrecha correlación entre ambos métodos desde las etapas iniciales de la enfermedad

    Determination of muon momentum in the MicroBooNE LArTPC using an improved model of multiple Coulomb scattering

    Full text link
    We discuss a technique for measuring a charged particle's momentum by means of multiple Coulomb scattering (MCS) in the MicroBooNE liquid argon time projection chamber (LArTPC). This method does not require the full particle ionization track to be contained inside of the detector volume as other track momentum reconstruction methods do (range-based momentum reconstruction and calorimetric momentum reconstruction). We motivate use of this technique, describe a tuning of the underlying phenomenological formula, quantify its performance on fully contained beam-neutrino-induced muon tracks both in simulation and in data, and quantify its performance on exiting muon tracks in simulation. Using simulation, we have shown that the standard Highland formula should be re-tuned specifically for scattering in liquid argon, which significantly improves the bias and resolution of the momentum measurement. With the tuned formula, we find agreement between data and simulation for contained tracks, with a small bias in the momentum reconstruction and with resolutions that vary as a function of track length, improving from about 10% for the shortest (one meter long) tracks to 5% for longer (several meter) tracks. For simulated exiting muons with at least one meter of track contained, we find a similarly small bias, and a resolution which is less than 15% for muons with momentum below 2 GeV/c. Above 2 GeV/c, results are given as a first estimate of the MCS momentum measurement capabilities of MicroBooNE for high momentum exiting tracks

    Design and construction of the MicroBooNE Cosmic Ray Tagger system

    Get PDF
    The MicroBooNE detector utilizes a liquid argon time projection chamber (LArTPC) with an 85 t active mass to study neutrino interactions along the Booster Neutrino Beam (BNB) at Fermilab. With a deployment location near ground level, the detector records many cosmic muon tracks in each beam-related detector trigger that can be misidentified as signals of interest. To reduce these cosmogenic backgrounds, we have designed and constructed a TPC-external Cosmic Ray Tagger (CRT). This sub-system was developed by the Laboratory for High Energy Physics (LHEP), Albert Einstein center for fundamental physics, University of Bern. The system utilizes plastic scintillation modules to provide precise time and position information for TPC-traversing particles. Successful matching of TPC tracks and CRT data will allow us to reduce cosmogenic background and better characterize the light collection system and LArTPC data using cosmic muons. In this paper we describe the design and installation of the MicroBooNE CRT system and provide an overview of a series of tests done to verify the proper operation of the system and its components during installation, commissioning, and physics data-taking
    corecore