121 research outputs found

    Component-Resolved in Vitro Diagnosis in Peach-Allergic Patients

    Get PDF
    BACKGROUND: The in vitro diagnosis of pollen-related food allergy presents low specifi city and reproducibility with many conventional extracts. This can be improved using natural purifi ed allergens, recombinant purifi ed allergens, or both. OBJECTIVE: We compared specifi c immunoglobulin (Ig) E determination (sIgE), the basophil activation test (BAT), the histamine release test (HRT), and the cellular allergen stimulation test (CAST) using natural and recombinant allergens in the diagnosis of peach allergy. METHODS: Thirty-two peach allergic patients were studied. Skin prick tests were performed with commercial peach and extract with Mal d 1, nPru p 3, and profi lin (nPho d 2). sIgE, BAT, CAST, and HRT were determined using rPru p 3, rMal d 3, rBet v 1, rMal d 1, and rMal d 4. RESULTS: Agreement between the techniques was good with all the allergens, except HRT with rMal d 1 and rMal d 4. With rPru p 3, sIgE, CAST, BAT, and HRT showed sensitivity values of 88%, 81%, 72%, and 69% and specifi city values of 100%, 93%, 97%, and 83%, respectively. In patients with systemic symptoms or contact urticaria, the values were 100%, 85%, 81%, and 81%. In patients with oral allergy syndrome, sensitivity to profi lins or homologues of Bet v 1 was detected in 100% of the cases by all the techniques, except by HRT with rMal d 1, which detected 66% of the cases. CONCLUSIONS: The use of single allergens in the in vitro diagnosis of peach allergy by specifi c IgE determination, BAT, and CAST offers high specifi city and sensitivity, with better results than the HRT

    Pru p 3 mutants exhibit low IgE-binding capacity: a good strategy for specific peach immunotherapy.

    Full text link
    Treatment of food allergy consists of the avoidance of the specific allergenic food. However, the possibility of cross-reactivity with other food sources makes this practice sometimes ineffective. The use of hypoallergenic molecules with the ability to stimulate T cells may be a promising tool for specific immunotherapy

    Test de activación de basófilos en el diagnóstico de alergia a medicamentos

    Get PDF
    In this paper we study the reliability of the basophil activation test (BAT) in the "in-vitro" diagnosis of allergy to betalactams and to metamizol, and the sensitivity and specificity of the technique are analyzed. To this end, we studied 58 patients allergic to betalactam antibiotics with a positive cutaneous test facing any derivative of penicillin and 30 healthy controls who tolerated betalactams, and 26 patients allergic to metamizol with an immediate reaction and 30 healthy controls who tolerated the medicine. Sensitivity to BAT in allergy to betalactams was 52.8%, and specificity was 92.6%. For metamizol, sensitivity was 42.3% and specificity was 100%. The positive predictive value of BAT in allergy to betalactams was 18.9% and the negative predictive value was 98.4%. For metamizol, the positive predictive value of the technique was 100% and the negative predictive value was 99.4%. The joint use of BAT and CAP (specific IgE) makes it possible to diagnose some 65% of patients allergic to betalactams. The combined use of cutaneous tests and BAT in allergy to metamizol detects 70% of the cases. BAT is a useful, non-invasive technique in the "in-vitro" diagnosis of allergy to betalactams and metamizol

    Nonsteroidal anti-inflammatory drug hypersensitivity syndrome. A multicenter study I. clinical findings and in vitro diagnosis

    Get PDF
    ackground: We present the results obtained from the largest series of in vitro diagnostic tests ever reported in patients with clinically validated hypersensitivity to acetylsalicylic acid (ASA)/nonsteroidal anti-infl ammatory drugs (NSAID) compared with various categories of controls tolerating ASA/NSAIDs. This multicenter study, which was performed within the framework of the European Network for Drug Allergy (ENDA) group, showed that the basophil activation test (BAT), particularly when used with the 3 NSAIDs aspirin (ASA), diclofenac (DIC), and naproxen (NAP), allows us to confi rm the diagnosis of NSAID hypersensitivity syndrome. The results of the cellular allergen stimulation test (CAST) frequently correlate with those of the BAT, although not always. An unexpected fi nding was that basophil activation by NSAIDs is not an all-or-nothing phenomenon restricted to clinically hypersensitive patients, but that it also occurs in a dose-related manner in some NSAID-tolerant control individuals. Therefore, NSAID hypersensitivity appears as a shift in the normal pharmacological response to NSAIDs. These fi ndings allow us to formulate a new rational hypothesis about the mechanism of NSAID hypersensitivity syndrome, a mechanism that most authors continue to describe as “unknown.” Methods: We enrolled 152 patients with a history of hypersensitivity to NSAIDs and 136 control participants in 11 different centers between spring 2003 and spring 2006. Flowcytometric BAT was performed. Results: The most noteworthy results of our study were that 57% of 140 patients presented very clear-cut positive BAT results to multiple NSAIDs, and 16% were entirely negative. In about 27% of cases, positive results were obtained with 1 or 2 concentrations of a single NSAID. There is clearly a correlation between the results of BAT and CAST. Conclusions: BAT seems particularly indicated in patients with a clinical history of NSAID intolerance, and in whom a provocation test is not advisable for ethical, clinical, or other reasons

    Topics in Noncommutative Geometry Inspired Physics

    Full text link
    In this review article we discuss some of the applications of noncommutative geometry in physics that are of recent interest, such as noncommutative many-body systems, noncommutative extension of Special Theory of Relativity kinematics, twisted gauge theories and noncommutative gravity.Comment: New references added, Published online in Foundations of Physic

    RICORS2040 : The need for collaborative research in chronic kidney disease

    Get PDF
    Chronic kidney disease (CKD) is a silent and poorly known killer. The current concept of CKD is relatively young and uptake by the public, physicians and health authorities is not widespread. Physicians still confuse CKD with chronic kidney insufficiency or failure. For the wider public and health authorities, CKD evokes kidney replacement therapy (KRT). In Spain, the prevalence of KRT is 0.13%. Thus health authorities may consider CKD a non-issue: very few persons eventually need KRT and, for those in whom kidneys fail, the problem is 'solved' by dialysis or kidney transplantation. However, KRT is the tip of the iceberg in the burden of CKD. The main burden of CKD is accelerated ageing and premature death. The cut-off points for kidney function and kidney damage indexes that define CKD also mark an increased risk for all-cause premature death. CKD is the most prevalent risk factor for lethal coronavirus disease 2019 (COVID-19) and the factor that most increases the risk of death in COVID-19, after old age. Men and women undergoing KRT still have an annual mortality that is 10- to 100-fold higher than similar-age peers, and life expectancy is shortened by ~40 years for young persons on dialysis and by 15 years for young persons with a functioning kidney graft. CKD is expected to become the fifth greatest global cause of death by 2040 and the second greatest cause of death in Spain before the end of the century, a time when one in four Spaniards will have CKD. However, by 2022, CKD will become the only top-15 global predicted cause of death that is not supported by a dedicated well-funded Centres for Biomedical Research (CIBER) network structure in Spain. Realizing the underestimation of the CKD burden of disease by health authorities, the Decade of the Kidney initiative for 2020-2030 was launched by the American Association of Kidney Patients and the European Kidney Health Alliance. Leading Spanish kidney researchers grouped in the kidney collaborative research network Red de Investigación Renal have now applied for the Redes de Investigación Cooperativa Orientadas a Resultados en Salud (RICORS) call for collaborative research in Spain with the support of the Spanish Society of Nephrology, Federación Nacional de Asociaciones para la Lucha Contra las Enfermedades del Riñón and ONT: RICORS2040 aims to prevent the dire predictions for the global 2040 burden of CKD from becoming true

    Searches for lepton-flavour-violating decays of the Higgs boson in s=13\sqrt{s}=13 TeV pp\mathit{pp} collisions with the ATLAS detector

    Get PDF
    This Letter presents direct searches for lepton flavour violation in Higgs boson decays, H → eτ and H → μτ , performed with the ATLAS detector at the LHC. The searches are based on a data sample of proton–proton collisions at a centre-of-mass energy √s = 13 TeV, corresponding to an integrated luminosity of 36.1 fb−1. No significant excess is observed above the expected background from Standard Model processes. The observed (median expected) 95% confidence-level upper limits on the leptonflavour-violating branching ratios are 0.47% (0.34+0.13−0.10%) and 0.28% (0.37+0.14−0.10%) for H → eτ and H → μτ , respectively.publishedVersio

    Combination of searches for Higgs boson pairs in pp collisions at \sqrts = 13 TeV with the ATLAS detector

    Get PDF
    This letter presents a combination of searches for Higgs boson pair production using up to 36.1 fb(-1) of proton-proton collision data at a centre-of-mass energy root s = 13 TeV recorded with the ATLAS detector at the LHC. The combination is performed using six analyses searching for Higgs boson pairs decaying into the b (b) over barb (b) over bar, b (b) over barW(+)W(-), b (b) over bar tau(+)tau(-), W+W-W+W-, b (b) over bar gamma gamma and W+W-gamma gamma final states. Results are presented for non-resonant and resonant Higgs boson pair production modes. No statistically significant excess in data above the Standard Model predictions is found. The combined observed (expected) limit at 95% confidence level on the non-resonant Higgs boson pair production cross-section is 6.9 (10) times the predicted Standard Model cross-section. Limits are also set on the ratio (kappa(lambda)) of the Higgs boson self-coupling to its Standard Model value. This ratio is constrained at 95% confidence level in observation (expectation) to -5.0 &lt; kappa(lambda) &lt; 12.0 (-5.8 &lt; kappa(lambda) &lt; 12.0). In addition, limits are set on the production of narrow scalar resonances and spin-2 Kaluza-Klein Randall-Sundrum gravitons. Exclusion regions are also provided in the parameter space of the habemus Minimal Supersymmetric Standard Model and the Electroweak Singlet Model. For complete list of authors see http://dx.doi.org/10.1016/j.physletb.2019.135103</p

    Comparison between simulated and observed LHC beam backgrounds in the ATLAS experiment at Ebeam =4 TeV

    Get PDF
    Results of dedicated Monte Carlo simulations of beam-induced background (BIB) in the ATLAS experiment at the Large Hadron Collider (LHC) are presented and compared with data recorded in 2012. During normal physics operation this background arises mainly from scattering of the 4 TeV protons on residual gas in the beam pipe. Methods of reconstructing the BIB signals in the ATLAS detector, developed and implemented in the simulation chain based on the \textscFluka Monte Carlo simulation package, are described. The interaction rates are determined from the residual gas pressure distribution in the LHC ring in order to set an absolute scale on the predicted rates of BIB so that they can be compared quantitatively with data. Through these comparisons the origins of the BIB leading to different observables in the ATLAS detectors are analysed. The level of agreement between simulation results and BIB measurements by ATLAS in 2012 demonstrates that a good understanding of the origin of BIB has been reached
    corecore