290 research outputs found

    Fatigue resistance of new and used nickel-titanium rotary instruments: a comparative study

    Get PDF
    Aim of the present study was twofold. First, to evaluate in vitro, the performance of two different NiTi rotary instruments in one molar case; then, to evaluate their resistance to cyclic fatigue, compared to new ones

    In vivo evaluation of operative torque generated by two Nickel-Titanium rotary instruments during root canal preparation

    Get PDF
    Objectives This in vivo study evaluated the operative torque and preparation time of ProTaper NEXT (Dentsply Maillefer; Ballaigues, Switzerland) and EdgeFile X7 (EdgeEndo; Albuquerque, New Mexico, United States) rotary systems during root canal preparation of maxillary premolars. Materials and Methods Ten double-rooted maxillary premolars with independent canals were selected. Each canal in each tooth was prepared with one of the rotary systems (n = 10), ProTaper NEXT or EdgeFile X7. The instruments were rotated at 300 rpm with maximum torque set at 2 N.cm using an electric motor (KaVo; Biberach, Germany) that automatically recorded torque values at every 1/10th of a second (ds). Statistical Analysis Operative torque (N.cm) and preparation time (s) of the first shaping instrument (size 17/.04) of both rotary systems were recorded and statistically compared using the Mann-Whiney U test with a significance level set at 5%. Results No instrument exhibited flute deformation or underwent intracanal failure. No differences were found between the instruments regarding the maximum (peak) torque values (p > 0.05). EdgeFile X7 17/.04 required significantly less preparation time (3.75 seconds interquartile range [IQR]: 3.2-9.0) than ProTaper NEXT X1 (15.45 seconds IQR: 8.35-21.1) (p < 0.05). The median operative torque values of ProTaper NEXT X1 (0.26 N.cm; IQR: 0.18-0.49) were significantly higher compared with EdgeFile X7 17/.04 (0.09 N.cm; IQR: 0.05-0.17) (p < 0.05). Conclusions Although no difference was found between the median peak torque values of ProTaper NEXT X1 and EdgeFile X7 17/.04 instruments, the operative torque and instrumentation time results were impacted by their different designs and alloys during clinical preparation of root canals

    Torsional resistance of two new heat treated nickel titanium rotary instruments: an in vitro evaluation

    Get PDF
    Objective: To evaluate the difference in torsional resistance, angular deflection and fragment length between two new rotary instruments: AF Blue S4 and S-One. These files share all features except cross-sectional design. Material and Methods: A total of 40 new Nickel-Titanium instruments of 25 mm in length were tested in this study and divided in two groups: 20 AF Blue S4, tip 25 and constant 6% taper and 20 AF-Blue S4 tip 25 and constant 6% taper. The torsional test was performed by the use of a torque recording endodontic motor (KaVo, Biberac, Germany). Torque to Fracture (TtF), Angular Deflection (AD) and Fragment Length (FL) was recorded for each instrument. To ensure an immovable block at 3mm of the instrument tip, an auto-polymerizing resin (DuraLay; Reliance Dental Mfg Co, Worth, IL) was used. Each file was rotated clockwise at a speed of 300 rpm until fracture occurred. Results: Group A (AF Blue S4) showed higher TtF and AD than Group B (S-One), and statistical analysis found significant differences between the two instruments (p<0.05). The mean values for FL showed no significant differences (p>0.05) between the two instruments. Conclusion: The AF Blue S4 seems to have a higher resistance to torsional stress in vitro. Clinically, the use of AF Blue S4 could be safer in narrow canals

    Anatomical variations and bilateral symmetry of roots and root canal system of mandibular first permanent molars in Saudi Arabian population utilizing cone- beam computed tomography

    Get PDF
    Aim: The aim of the study was to evaluate the anatomical variations of the roots and root canal system, and to determine the symmetry between right and left sides of mandibular first permanent molars in Saudi Arabian population using images derived from cone beam computed tomography (CBCT) scans. Methods: The CBCT scans (with the following parameters: FOV 170 × 120 mm, 90 Kv, 5–8 mA, 17.5 s exposure time and 0.25 mm voxel size) were retrieved from the database and axial, coronal and sagittal sections of mandibular first molars were examined. The number of roots, canals and type of canal configuration based on Vertucci's classification were recorded. Bilateral symmetry between right and left side of the same individuals and differences between genders were investigated. Results: Out of 174 mandibular first molars, 97.1% were two rooted and 2.9% were three rooted (distolingual root). In regards to the number of canals, 73% had three, 25.3% had four and 1.7% had two root canals. In teeth with four root canals, 90.9% of the extra canal was in the distal root, while 9.1% in the extra distolingual root. The most common canal configuration in mesial and distal root were type IV (64.9%) and type I (77%), respectively. Symmetrical analysis revealed 100% symmetry in number of roots and 56.4% in number of canals between right and left teeth in the same individual. Conclusions: Within the limitation of this study, wide range of canals configurations were noted in mandibular first molars among the Saudi Arabian population. The prevalence of three rooted mandibular first molars was relatively low. Three canals were most commonly seen in mandibular first molars. Bilateral symmetry was varied in number of canals and canals configurations, which could be of clinical significance while performing root canal treatment on both side mandibular first permanent molars

    Torque range, a new parameter to evaluate new and used instrument safety

    Get PDF
    The aim of the present study is to evaluate operative torque, torque at failure and the difference between these two values-the "torque range"-of two different NiTi files. We also sought to evaluate and compare these parameters for new and used files. Forty S-One 20.06 and forty M-Two 20.06 were tested, divided in four equal groups (n = 10) for each brand. Ten instruments from each brand performed three root canal treatments each on standardized extracted single-rooted teeth. Afterwards, each group was subjected to the following two tests: operative torque and torsional resistance. Mean values for all the tested groups were calculated. The results for new instruments showed that S-One developed significantly higher operative torque, but higher torsional resistance. The results for used instruments showed that the S-One 20.06 developed less operative torque and higher mean torsional resistance value compared to the M-Two. Moreover, the percentage reduction of both values was significantly higher for M-Two. The results of the present study showed a safer torsional behavior of the S-One. These results could be related to the heat treatment and the manufacturing process

    Fatigue resistance of two Nickel-Titanium rotary instruments before and after ex vivo root canal treatment

    Get PDF
    Aim: The aim of the present study is twofold: to evaluate cyclic fatigue resistance differences of two different nickel-titanium rotary instruments, brand new and after an ex vivo instrumentation of single root extracted teeth. Materials and methods: Twenty new S One 20.06 were randomly divided into two groups. The first group (n = 10) was immediately subjected to a cyclic fatigue test (S One Group I). The second group (n = 10) (S one Group II) performed a cyclic fatigue test after three ex vivo root canal treatment with a single-file technique. The same process has been carried out for 20 M-Two 20.06 instruments. Results: Mean time to fracture (TtF) for Group I was 51.14 ± 1.28 for S One and 32.62 ± 0.17 for M-Two 20.06 and for Group II was 46.00 ± 0.99 for S One and 27.75 ± 1.58 for M-Two 20.06. The reduction in TtF values from Group I to Group II was 11% for S One and 15% for M-Two. Statistical analysis found significant differences in all the groups examined (p value < 0.05). Mean fragment length (FL) for Group I was 3.07 ± 0.17 for S One and 3.05 ± 0.14 for M-Two 20.06 and for Group II was 3.05 ± 0.07 for S One and 3.05 ± 0.14 for M-Two 20.06. Statistical analysis was pursued, and no significant difference was found (p value > 0.05). Conclusion: The S-One showed significantly more resistance to cyclic fatigue stress than M-Two for both new and used instruments. This validates the hypothesis that the AF H wire enables the S One files to endure more the cyclic fatigue stresses. Clinical significance: This study demonstrates the cyclic fatigue resistance of a new endodontic instrument after repetitive usage

    Assessment of real-time operative torque during nickel-titanium instrumentation with different lubricants

    Get PDF
    The aim of the present study is twofold: to assess ex vivo the role of different lubricants on real-time torque generated during intracanal instrumentation and to check whether two different kinds of torque parameters, operative torque (OT) and average peak torque (APT), could produce similar results. Forty extracted single-rooted teeth were selected for the present study and divided into four equal groups (n = 10): Group A, NaCl 0.2%; Group B, NaOCl 5%; Group C, ethylenediaminetetraacetate (EDTA), and Group D, EDTA and hydrogen peroxide. Afterwards, Edge Taper F2 (Edge Endo, Albuquerque, New Mexico) were rotated clockwise at 300 rpm with 3 Ncm maximum torque by an endodontic torque recording motor. In each sample, mean OT and mean APT were recorded and statistically analyzed with one-way ANOVA and a post hoc Bonferroni between groups (p < 0.05). EDTA (12.11 ± 4.45 Ncm) showed statistically significant (p < 0.05) lower values compared with the other tested irrigant for both parameters. Overall, the two different parameters were both able to differentiate between the influence of lubricants on torsional loads
    • …