61 research outputs found
PATENT FORAMEN OVALE CLOSURE WITH A CONVENTIONAL RADIOFREQUENCY ABLATION CATHETER: EARLY FEASIBILITY
Biomarkers of myocardial injury with different energy sources for atrial fibrillation catheter ablation
Background: Our study aims to compare acute myocardial injury biomarker rise after atrial fibrillation ablation performed with different technologies.Methods and Results: One hundred and ten patients were treated with pulmonary vein isolation with 4 different technologies: open-irrigated tip radiofrequency (RF) catheter in35 patients (Group A), cryoballoon in 35 patients (Group B), visually guided laser balloon in 20 patients (Group C), open-irrigated tip RF catheter with contact-force-sensing technology in 20 patients (Group D). Post-procedure samples of cardiac troponin I (cTnI) and creatinine kinase-MB (CK-MB) were collected at 19 ± 3 h and 43 ± 3 h after ablation. At the first postprocedural sample, cTnI and CK-MB levels were found elevated in all 110 patients with a median value of 2.11 ng/mL and 8.95 ng/mL, respectively. Group B showed cTnI levels increased (median 5.96 ng/mL) compared to other groups (median Group A: 1.72 ng/mL, Group C: 1.54 ng/mL, Group D: 2.0 ng/mL; p < 0.001). Also CK-MB levels resulted higher in cryoablation (median 26.4 ng/mL) compared to other groups (median Group A: 6.40 ng/mL, Group C: 7.15 ng/mL, Group D: 6.50 ng/mL; p < 0.001). No significant association was observed between biomarker levels and recurrences of atrial fibrillation after a mean follow-up of 369 ± 196 days.Conclusions: Highest markers for myocardial injury were observed in the cryoballoon group. It is possible that a longer delivery energy duration and other factors affecting lesion size resulted in higher amount of cardiac injury in cryoablation. The higher levels of cardiac biomarkers did not translate into a better outcome and its physiologic significance is unknown.
471 Arrhythmia-free survival in early-persistent atrial fibrillation patients undergoing radiofrequency catheter ablation
Abstract
Aims
Despite advances in success rate of paroxysmal atrial fibrillation (PAF) ablation, outcomes of radiofrequency catheter ablation (RFCA) in patients with persistent AF are highly variable. Early persistent AF (EPsAF) is defined as AF that is sustained beyond 7 days but is less than 3 months in duration. Arrhythmia-free survival data after RFCA in this specific population are still limited. We sought to report the outcomes of RFCA in the subgroup of patients with EPsAF, compared to those with PAF and with 'late' persistent AF (LPsAF) lasting between 3 and 12 months.
Methods and results
Data from 1143 consecutive AF patients receiving their first RFCA were prospectively collected. Patients with EPsAF (n = 190) were compared with PAF (n = 531) and LPsAF (n = 422) patients. All patients received pulmonary vein antrum isolation + posterior wall and sustained non-pulmonary vein (PV) trigger ablation. Non-sustained non-PV triggers were ablated based on operator discretion. Non-PV triggers were defined as sites of firing leading to sustained (>30 s) or non-sustained arrhythmias (<30 s, including premature atrial contractions ≥10 beats/min) with earliest activation outside the PVs. Mean age of the population was 64 ± 11 years. Female patients were more in PAF group (39%) compared to EPsAF (26%) and LPsAF (28%) (P < 0.001). There was no difference in other clinical characteristics among populations. Non-PV triggers were detected more in EPsAF [127 (66.8%)], and LPsAF [296 (70.1%)] patients compared to PAF [185 (34.8%)] (P < 0.001).One-year arrhythmia-free survival rate after a single procedure was 75.0% (398), 74.2% (141), and 64.5% (272) in PAF, EPsAF, and LPsAF, respectively. Success rate was significantly higher in PAF {[HR: 0.67 (0.53, 0.84), P = 0.001] and EPsAF [HR: 0.67 (0.49, 0.93)], P = 0.015} compared to LPsAF.
Conclusions
In patients with EPsAF, RFCA may result in significantly better freedom from atrial arrhythmias, compared to LPsAF. In this cohort, ablation might be reasonable as first line approach to improve outcomes and prevent AF progression
Long-term Outcome of Pulmonary Vein Isolation Versus Amiodarone Therapy in Patients with Coexistent Persistent AF and Congestive Heart Failure
Although pharmacological rhythm control of AF in patients with heart failure with reduced ejection fraction (HFrEF) does not seem to provide any benefit over rate control, catheter ablation of AF has been shown to improve clinical outcomes. These results can be explained with higher success rates of catheter ablation in restoring and maintaining sinus rhythm compared with antiarrhythmic drugs. In addition, pharmacotherapy is not void of side-effects, which are thought to offset its potential antiarrhythmic benefits. Therefore, efforts should be made towards optimisation of ablation techniques for AF in patients with HFrEF
478 Clinical outcomes of patients at very high stroke risk undergoing watchman implantation
Abstract
Aims
Left atrial appendage occlusion (LAAO) with the Watchman device is an effective alternative to oral anticoagulation in patients with non-valvular atrial fibrillation at high thromboembolic risk. We sought to evaluate the safety and effectiveness of LAAO for stroke and bleeding prevention in patients at very high stroke risk.
Methods and results
Data were extracted from a prospective database of 488 AF patients who underwent LAA closure with a Watchman device. Periprocedural complications, thromboembolic (TE), and bleeding event rates among patients with a CHA2DS2-VASc ≥ 5 were reported. Predicted annual rates of TE or major bleeding events were compared to the annualized observed risk of the population. Overall, 209 patients with a CHA2DS2-VASc ≥5 (CHA2DS2-VASc: 6.0 ± 1.0; HAS-BLED: 3.7 ± 1.1) were included in the study. The mean age was 78 ± 6 years and 52.2% (n = 109) were males. Watchman implantation was successful in all patients. Overall procedure-related complication rate was 3.3% (n = 7). Two major complications were observed (1.0%): one pericardial tamponade requiring surgery and one major bleeding event at 3 days post-procedure. The incidence of minor complications was 2.3% (n = 5). Specifically, two patients experienced a pericardial effusion that required drainage and three had a groin hematoma. During a mean follow-up duration of 12 ± 5 months (193 pt/years), six TE events (2.9%/annualized rate: 3.1%) were documented after a median of 6.3 months (IQR: 2.2–9.6). Based on the estimated annual TE risk according to the CHA2DS2-VASc score (8.5%), the % risk reduction after LAAO was 63.5%. Four major bleeding events [1.9% (median time to event: 2.1 months; IQR: 1.0–3.4)] and five minor bleeding events occurred (2.5%) during follow-up. Compared to the expected rate of bleeding events as assessed by the HAS-BLED of the population (8.03%), LAAO led to a 42% reduction of bleeding risk.
Conclusions
In a population at very high TE risk, LAAO with the Watchman device was a safe and effective approach, and led to a 63.5% of stroke risk
PATENT FORAMEN OVALE CLOSURE WITH A CONVENTIONAL RADIOFREQUENCY ABLATION CATHETER: EARLY FEASIBILITY
Impact of metabolic syndrome on ablation-outcome in patients with atrial fibrillation: A systematic review
Metabolic syndrome (MS), a pro-inflammatory state with hypertension, diabetes, dyslipidemia and obesity is presumed to be a close associate of atrial fibrillation (AF). However, the exact mechanism by which MS facilitates perpetuation of AF is yet to be fully understood. Moreover, the impact of the components of MS as well as MS as a group, on ablation-outcome in AF is not clearly elucidated until now. This review has compiled the results from major studies that have looked into those risk factors and defined their significance in influencing ablation-outcome in AF. It has also overviewed the impact of life-style changes that might improve the success rate of AF-ablation by effectively addressing the different constituents of MS
- …