4 research outputs found
Ultrasound Characterization of Patellar Tendon in Non-Elite Sport Players with Painful Patellar Tendinopathy: Absolute Values or Relative Ratios? A Pilot Study
Imaging findings in patellar tendinopathy are questioned. The aim of this pilot study was to characterize ultrasound measures, by calculating ultrasound ratio and neovascularization of the patellar tendon in non-elite sport players with unilateral painful patellar tendinopathy. Cross-sectional area (CSA), width, and thickness of the patellar tendon were assessed bilaterally in 20 non-elite sport-players with unilateral painful patellar tendinopathy and 20 asymptomatic controls by a blinded assessor. Ultrasound ratios were calculated to discriminate between symptomatic and asymptomatic knees. The Ohberg score was used for characterizing neovascularization. We found that non-elite sport players with patellar tendinopathy exhibited bilateral increases in CSA, width, and thickness of the patellar tendon compared to asymptomatic controls (Cohen d > 2). The ability of ultrasound ratios to discriminate between painful and non-painful patellar tendons was excellent (receiver operating characteristic, ROC > 0.9). The best diagnostic value (sensitivity: 100% and specificity: 95%) was observed when a width ratio ≥ 1.29 between the symptomatic and asymptomatic patellar tendon was used as a cut-off. Further, neovascularization was also observed in 70% of non-elite sport players with unilateral patellar tendinopathy. A greater CSA ratio was associated with more related-disability and higher tendon neovascularization. This study reported that non-elite sport players with painful unilateral patellar tendinopathy showed structural ultrasound changes in the patellar tendon when compared with asymptomatic controls. Ultrasound ratios were able to discriminate between symptomatic and asymptomatic knees. Current results suggest that ultrasound ratios could be a useful imaging outcome for identifying changes in the patellar tendon in sport players with unilateral patellar tendinopathy
Ultrasound Characterization of Patellar Tendon in Non-Elite Sport Players with Painful Patellar Tendinopathy: Absolute Values or Relative Ratios? A Pilot Study
Imaging findings in patellar tendinopathy are questioned. The aim of this pilot study was to characterize ultrasound measures, by calculating ultrasound ratio and neovascularization of the patellar tendon in non-elite sport players with unilateral painful patellar tendinopathy. Cross-sectional area (CSA), width, and thickness of the patellar tendon were assessed bilaterally in 20 non-elite sport-players with unilateral painful patellar tendinopathy and 20 asymptomatic controls by a blinded assessor. Ultrasound ratios were calculated to discriminate between symptomatic and asymptomatic knees. The Ohberg score was used for characterizing neovascularization. We found that non-elite sport players with patellar tendinopathy exhibited bilateral increases in CSA, width, and thickness of the patellar tendon compared to asymptomatic controls (Cohen d > 2). The ability of ultrasound ratios to discriminate between painful and non-painful patellar tendons was excellent (receiver operating characteristic, ROC > 0.9). The best diagnostic value (sensitivity: 100% and specificity: 95%) was observed when a width ratio ≥ 1.29 between the symptomatic and asymptomatic patellar tendon was used as a cut-off. Further, neovascularization was also observed in 70% of non-elite sport players with unilateral patellar tendinopathy. A greater CSA ratio was associated with more related-disability and higher tendon neovascularization. This study reported that non-elite sport players with painful unilateral patellar tendinopathy showed structural ultrasound changes in the patellar tendon when compared with asymptomatic controls. Ultrasound ratios were able to discriminate between symptomatic and asymptomatic knees. Current results suggest that ultrasound ratios could be a useful imaging outcome for identifying changes in the patellar tendon in sport players with unilateral patellar tendinopathy.Depto. de RadiologĂa, RehabilitaciĂłn y FisioterapiaFac. de EnfermerĂa, Fisioterapia y PodologĂaTRUEpu
Application of Percutaneous Needle Electrolysis Does Not Elicit Temperature Changes: An In Vitro Cadaveric Study
Percutaneous needle electrolysis (PNE) consists of the ultrasound-guided application of a galvanic electrical current through a solid filament needle. One proposed therapeutic mechanism for this intervention is a potential thermal effect. The aim of this study was to investigate if the application of PNE induces changes in temperature in different cadaveric musculoskeletal tissues. A repeated measure experimental cadaveric study was designed with 10 cryopreserved knees (5 men, 5 women). Sterile stainless-steel needles of 40 mm length and 0.30 mm caliber were used in this study. An ultrasound-guided needling puncture was performed in the targeted tissue (patellar tendon, infra-patellar fat, and vastus medialis muscle). Additionally, the tip of the needle was placed next to the thermometer sensor at the minimum possible distance without direct contact with it. The temperature differences before and after different applications were measured. The applications were: three applications for 3 s of 3 mA of intensity (3:3:3) when the tendon was the targeted tissue, three applications for 3 s of 1.5 mA of intensity (1.5:3:3) when the fat or muscle was the targeted tissue, and 24 s of 1 mA of intensity (1:24:1) in all tissues. No statistically significant Group*Time interactions were found in any tissue (tendon: F = 0.571, p = 0.459, ŋ2 = 0.03; fat pad: F = 0.093; p = 0.764, ŋ2 = 0.01; muscle: F = 0.681; p = 0.420, ŋ2 = 0.04). Overall, no changes in temperature were observed between both applications in the tendon (3:3:3 vs. 1:24:1) and fat/muscle (1.5:3:3 vs. 1:24:1) tissues. The application of two different percutaneous needle electrolysis protocols did not produce appreciable thermal changes in the tendon, fat, and muscle tissues of human cadavers. The results from the current cadaver study support that a thermal effect should not be considered as a mechanism of clinical action regardless of the targeted human tissue when applying percutaneous needle electrolysis since no changes in temperature after its application were observed
Precision and safety of ultrasound-guided versus palpation-guided needle placement on the patellar tendon: a cadaveric study
For decades, needling interventions have been performed based on manual palpation and anatomic knowledge. The increasing use of real-time ultrasonography in clinical practice has improved the accuracy and safety of needling techniques. Although currently ultrasound-guided procedures are routinely used for patellar tendon pathology, e.g., during percutaneous electrolysis, the accuracy of these procedures is still unknown. This study used a cadaveric model to compare and evaluate both the accuracy and safety of ultrasound-guided and palpation-guided needling techniques for the patellar tendon. A total of five physical therapists performed a series of 20 needle insertion task each (n = 100), 10 insertions based on manual palpation (n = 50) and 10 insertions guided with ultrasound (n = 50) to place a needle along the interface between the patellar tendon and Hoffa’s fat pad. All procedures were performed on cryopreserved knee specimens. Distance to the targeted tissue, time of the procedure, accurate rate of insertions, number of passes, and unintentional punctured structures between both applications (with and without ultrasound guiding) were compared. The results revealed higher accuracy (100% vs. 80%), a lower distance from needle to the targeted tissue (0.25 ± 0.65 vs. 2.5 ± 1.9 mm), longer surface of contact with the needle (15.5 ± 6.65 vs. 4.7 ± 7.5 mm), and a lower frequency of patellar tendon puncture (16% vs. 52%, p < 0.001) with the ultrasound-guided procedure as opposed to palpation-guided one. Nevertheless, the ultrasound-guided procedure took longer (54.8 ± 26.8 vs. 23.75 ± 15.4 s) and required more passes (2.55 ± 1.9 vs. 1.5 ± 0.95) to be conducted than the palpation-guided procedure (all, p < 0.001). According to these findings, the accuracy of invasive procedures applied on the patellar tendon is higher when conducted with ultrasound guidance than when conducted just on manual palpation or anatomical landmark. These results suggest that ultrasound could improve the clinical application of invasive procedures at the fat-patellar tendon interface. Due to the anatomical features of the targeted tissue, some procedures require this precision, so the use of ultrasound is recommended