163 research outputs found

    Evaluation of Corn Distillers Solubles on Growing Steer Performance

    Get PDF
    A growing study evaluated increasing inclusions of corn distillers solubles (CDS) at 10, 20, 30, and 40%, or increasing wet distillers grains plus solubles (WDGS) at 10, 20, 30, and 40% compared to a corn control. Corn was replaced by CDS or WDGS in each forage-based diet. Increasing CDS resulted in a quadratic increase for both DMI and F:G. Increasing WDGS linearly increased both DMI and ADG with no effect on F:G. The energy value of CDS is less than that of corn, whereas WDGS had an energy value similar to corn in growing diets with 50% brome hay. A 73.7% TDN value was determined for CDS at 40% inclusion in forage-based diets

    Evaluation of Corn Distillers Solubles on Finishing Steer Performance

    Get PDF
    A finishing study was conducted to evaluate the effects of feeding 0, 8, 16, or 20% corn distillers solubles (CDS), as well as the effects of feeding a combination of 16% CDS and 20% wet distillers grains plus solubles (WDGS) to replace a blend of dry-rolled and high-moisture corn on finishing steer performance. As inclusions of CDS increased, ADG linearly increased and F:G linearly decreased. Feeding value of CDS at 20% inclusion was determined to be 147% compared to the corn blend. The addition of WDGS resulted in a decrease in DMI with similar ADG, resulting in a decrease in F:G. Feeding a combination of CDS and WDGS resulted in a feeding value of 161% compared to corn. Feeding CDS up to 20% or in combination with WDGS displaces corn in finishing diets and improves ADG and F:G

    The Reliability of Parafoveal Cone Density Measurements

    Get PDF
    Background Adaptive optics scanning light ophthalmoscopy (AOSLO) enables direct visualisation of the cone mosaic, with metrics such as cone density and cell spacing used to assess the integrity or health of the mosaic. Here we examined the interobserver and inter-instrument reliability of cone density measurements. Methods For the interobserver reliability study, 30 subjects with no vision-limiting pathology were imaged. Three image sequences were acquired at a single parafoveal location and aligned to ensure that the three images were from the same retinal location. Ten observers used a semiautomated algorithm to identify the cones in each image, and this was repeated three times for each image. To assess inter-instrument reliability, 20 subjects were imaged at eight parafoveal locations on one AOSLO, followed by the same set of locations on the second AOSLO. A single observer manually aligned the pairs of images and used the semiautomated algorithm to identify the cones in each image. Results Based on a factorial study design model and a variance components model, the interobserver study\u27s largest contribution to variability was the subject (95.72%) while the observer\u27s contribution was only 1.03%. For the inter-instrument study, an average cone density intraclass correlation coefficient (ICC) of between 0.931 and 0.975 was calculated. Conclusions With the AOSLOs used here, reliable cone density measurements can be obtained between observers and between instruments. Additional work is needed to determine how these results vary with differences in image quality

    X-RHex: A Highly Mobile Hexapedal Robot for Sensorimotor Tasks

    Get PDF
    We report on the design and development of X-RHex, a hexapedal robot with a single actuator per leg, intended for real-world mobile applications. X-RHex is an updated version of the RHex platform, designed to offer substantial improvements in power, run-time, payload size, durability, and terrain negotiation, with a smaller physical volume and a comparable footprint and weight. Furthermore, X-RHex is designed to be easier to build and maintain by using a variety of commercial off-the-shelf (COTS) components for a majority of its internals. This document describes the X-RHex architecture and design, with a particular focus on the new ability of this robot to carry modular payloads as a laboratory on legs. X-RHex supports a variety of sensor suites on a small, mobile robotic platform intended for broad, general use in research, defense, and search and rescue applications. Comparisons with previous RHex platforms are presented throughout, with preliminary tests indicating that the locomotive capabilities of X-RHex can meet or exceed the previous platforms. With the additional payload capabilities of X-RHex, we claim it to be the first robot of its size to carry a fully programmable GPU for fast, parallel sensor processing

    Controlled comparison of hemodialysis and peritoneal dialysis: Veterans Administration multicenter study

    Get PDF
    Controlled comparison of hemodialysis and peritoneal dialysis: Veterans Administration multicenter study. We measured mortality and morbidity among 114 patients assigned randomly to home hemodialysis (HD) and home intermittent peritoneal dialysis (IPD). Data were collected during the time of home training and for 12 months after initiation of home dialysis. Training time was shorter for the IPD than for the HD patients (P < 0.001) with median time 1.8 months for IPD and 3.9 months for HD. Switching to the alternative mode of treatment was more frequent for the IPD group (29/59 vs. 5/55, P < 0.001). Survival time was not different, perhaps because of the modality change. More IPD patients were hospitalized in the first 6 months (20 for IPD vs. 9 for HD, P = 0.02), but they had fewer troublesome cardiovascular events in the first year (0 vs. 12, P < 0.001). The HD patients maintained better nutritional status as reflected in body weight and arm muscle circumference and possibly in urea appearance rate. Thus, these data suggest that for most patients, IPD is a less satisfactory form of therapy than HD, but certain advantages of IPD did emerge. Applications of this information to the currently more popular mode of CAPD await further study.Comparaison contrôlée entre l'hémodialyse et la dialyse péritonéale: Étude multicentrique de l'Administration des Veterans. Nous avons mesuré la mortalité et la morbidité chez 114 malades, pris au hasard, en hémodialyse à domicile (HD) ou en dialyse péritonéale intermittente à domicile (IPD). Les données ont été recueillies pendant l'entrainement à domicile et pendant les 12 mois suivant le début de la dialyse à domicile. La durée d'entrainement était plus brève pour les malades en IPD que pour ceux en HD (P < 0,001), avec un temps médian de 1,8 mois pour l'IPD et de 3,9 mois pour l'HD. Le changement pour l'autre mode de traitement était plus fréquent pour le groupe IPD (29/59 contre 5/55, P < 0,001). La durée de suivi n'était pas différente, peut-être à cause du changement de modalité. Plus de malades en IPD ont été hospitalisés dans les 6 premiers mois (20 en IPD, contre 9 en HD, P = 0,02), mais ils ont eu moins d'ennuis cardiovasculaires gênants au cours de la première année (0 contre 12, P < 0,001). Les malades HD conservaient un meilleur état nutritionnel, reflété par le poids corporel, la circonférence musculaire du bras, et probablement la vitesse d'apparition de l'urée. Ainsi ces données suggèrent que pour la plupart des malades, l'IPD est une forme de traitement moins satisfaisante que l'HD, mais certains avantages de l'IPD sont apparus. Les applications de cette information au mode actuellement le plus répandu de CAPD requièrent d'autres études

    Co-evolution of TH1, TH2 and TH17 Responses During Repeated Pulmonary Exposure to Aspergillus fumigatus Conidia

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/89973/1/white-coevolution_th1_th2.pd

    miR-126 Regulates Distinct Self-Renewal Outcomes in Normal and Malignant Hematopoietic Stem Cells

    Get PDF
    SummaryTo investigate miRNA function in human acute myeloid leukemia (AML) stem cells (LSC), we generated a prognostic LSC-associated miRNA signature derived from functionally validated subpopulations of AML samples. For one signature miRNA, miR-126, high bioactivity aggregated all in vivo patient sample LSC activity into a single sorted population, tightly coupling miR-126 expression to LSC function. Through functional studies, miR-126 was found to restrain cell cycle progression, prevent differentiation, and increase self-renewal of primary LSC in vivo. Compared with prior results showing miR-126 regulation of normal hematopoietic stem cell (HSC) cycling, these functional stem effects are opposite between LSC and HSC. Combined transcriptome and proteome analysis demonstrates that miR-126 targets the PI3K/AKT/MTOR signaling pathway, preserving LSC quiescence and promoting chemotherapy resistance

    The effects of Jesus and God on pro-sociality and discrimination

    Get PDF
    This study contributes to the debate over whether religion is a force for social good or harm. It shows that different belief concepts within the same religion can have different effects on distributive behaviour. A dictator game experiment, with two different charities as potential recipients, measures how priming the concepts of God and Jesus affects both the pro-sociality of Christians and their propensity to discriminate against LGBTQ people, an identity group traditionally opposed by their religion. Priming Jesus significantly raises the amounts Christians give to charity, but priming God has no such effect. Christians are found, at borderline significance, to discriminate against LGBTQ people, but this discrimination does not significantly increase when Jesus or God are primed
    • …
    corecore