7 research outputs found

    Frank-Starling control of a left ventricular assist device

    Get PDF
    A physiological control system was developed for a rotary left ventricular assist device (LVAD) in which the target pump flow rate (LVADQ) was set as a function of left atrial pressure (LAP), mimicking the Frank-Starling mechanism. The control strategy was implemented using linear PID control and was evaluated in a pulsatile mock circulation loop using a prototyped centrifugal pump by varying pulmonary vascular resistance to alter venous return. The control strategy automatically varied pump speed (2460 to 1740 to 2700 RPM) in response to a decrease and subsequent increase in venous return. In contrast, a fixed-speed pump caused a simulated ventricular suction event during low venous return and higher ventricular volumes during high venous return. The preload sensitivity was increased from 0.011 L/min/mmHg in fixed speed mode to 0.47L/min/mmHg, a value similar to that of the native healthy heart. The sensitivity varied automatically to maintain the LAP and LVADQ within a predefined zone. This control strategy requires the implantation of a pressure sensor in the left atrium and a flow sensor around the outflow cannula of the LVAD. However, appropriate pressure sensor technology is not yet commercially available and so an alternative measure of preload such as pulsatility of pump signals should be investigated

    Simulation and enhancement of a cardiovascular device test rig

    Get PDF
    Cardiovascular assist devices are tested in mock circulation loops (MCLs) prior to animal and clinical testing. These MCLs rely on characteristics such as pneumatic parameters to create pressure and flow, and pipe dimensions to replicate the resistance, compliance and fluid inertia of the natural cardiovascular system. A mathematical simulation was developed in SIMULINK to simulate an existing MCL. Model validation was achieved by applying the physical MCL characteristics to the simulation and comparing the resulting pressure traces. These characteristics were subsequently altered to improve and thus predict the performance of a more accurate physical system. The simulation was successful in simulating the physical mock circulation loop, and proved to be a useful tool in the development of improved cardiovascular device test rigs

    Biventricular assist devices: A technical review

    Get PDF
    The optimal treatment option for end stage heart failure is transplantation; however, the shortage of donor organs necessitates alternative treatment strategies such as mechanical circulatory assistance. Ventricular assist devices (VADs) are employed to support these cases while awaiting cardiac recovery or transplantation, or in some cases as destination therapy. While left ventricular assist device (LVAD) therapy alone is effective in many instances, up to 50% of LVAD recipients demonstrate clinically significant postoperative right ventricular failure and potentially need a biventricular assist device (BiVAD). In these cases, the BiVAD can effectively support both sides of the failing heart. This article presents a technical review of BiVADs, both clinically applied and under development. The BiVADs which have been used clinically are predominantly first generation, pulsatile, andparacorporeal systems that are bulky and prone to device failure, thrombus formation, and infection. While they have saved many lives, they generally necessitate a large external pneumatic driver which inhibits normal movement and quality of life for many patients. In an attempt to alleviate these issues, several smaller, implantable second and third generation devices that use either immersed mechanical blood bearings or hydrodynamic/magnetic levitation systems to support a rotating impeller are under development or in the early stages of clinical use. Although these rotary devices may offer a longer term, completely implantable option for patients with biventricular failure, their control strategies need to be refined to compete with the inherent volume balancing ability of the first generation devices. The BiVAD systems potentially offer an improved quality of life to patients with total heart failure, and thus a viable alternative to heart transplantation is anticipated with continued development

    Interdependency of freezing and thawing rates on cryopreserved human t cells

    No full text
    Interdependency of freezing and thawing rates on cryopreserved human t cells. 55. Annual Meeting of the Society for Cryobiolog

    The Impact of varying cooling and thawing rates on the quality of cryopreserved human peripheral blood t cells

    No full text
    For the clinical delivery of immunotherapies it is anticipated that cells will be cryopreserved and shipped to the patient where they will be thawed and administered. An established view in cellular cryopreservation is that following freezing, cells must be warmed rapidly (≤5 minutes) in order to maintain high viability. In this study we examine the interaction between the rate of cooling and rate of warming on the viability, and function of T cells formulated in a conventional DMSO based cryoprotectant and processed in conventional cryovials. The data obtained show that provided the cooling rate is -1 °C min-1 or slower, there is effectively no impact of warming rate on viable cell number within the range of warming rates examined (1.6 °C min-1 to 113 °C min-1). It is only following a rapid rate of cooling (-10 °C min-1) that a reduction in viable cell number is observed following slow rates of warming (1.6 °C min-1 and 6.2 °C min-1), but not rapid rates of warming (113 °C min-1 and 45 °C min-1). Cryomicroscopy studies revealed that this loss of viability is correlated with changes in the ice crystal structure during warming. At high cooling rates (-10 °C min-1) the ice structure appeared highly amorphous, and when subsequently thawed at slow rates (6.2 °C min-1 and below) ice recrystallization was observed during thaw suggesting mechanical disruption of the frozen cells. This data provides a fascinating insight into the crystal structure dependent behaviour during phase change of frozen cell therapies and its effect on live cell suspensions. Furthermore, it provides an operating envelope for the cryopreservation of T cells as an emerging industry defines formulation volumes and cryocontainers for immunotherapy products