40 research outputs found
Re-storying and visualizing the changing entrepreneurial identities of Bill Gates and Richard Branson.
The storytelling in textual and visual re-constructions of Bill Gates and Richard Branson by their organizations produces entrepreneurial identities bound into particular social power-knowledge relations. Our purpose is to examine how these organizations, and their critics, mobilize storytelling in acts of re-storying (enlivening) or re-narrating (branding a monologic) practices using Internet technologies to invite viewers to frame the world of entrepreneurship. We use visual discourse and storytelling methods to analyze how Microsoft and Virgin Group use various kinds of entrepreneurial images and textual narratives to re-narrate and produce particular brands of capitalism. These organizations' scoptic regimes of representation are contested in counter-visualizing and counterstory practices of external stakeholders. We suggest that the image and textual practices of storytelling have changed as both entrepreneurs court philanthropic and social entrepreneur identity markers. Our contribution to entrepreneurial identity is to apply double and multiple narrations, the appropriation of another's narrative words (or images) into another's narrative, and relate such storytelling moves to visuality
Diagnostic performance of exercise bicycle testing and single-photon emission computed tomography: Comparison with 64-slice computed tomography coronary angiography
To conduct a comparison of the diagnostic performance of exercise bicycle testing and singlephoton emission computed tomography (SPECT) with computed tomography coronary angiography (CTCA) for the detection of obstructive coronary artery disease (CAD) in patients with stable angina. 376 symptomatic patients (254 men, 122 women, mean age 60.4 ± 10.0 years) referred for noninvasive stress testing (exercise bicycle test and/or SPECT) and invasive coronary angiography were included. All patients underwent additional 64-slice CTCA. The diagnostic performance of exercise bicycle testing (ST segment depression), SPECT (reversible perfusion defect) and CTCA (≥50% lumen diameter reduction) was presented as sensitivity, specificity, positive and negative predictive value (PPV and NPV) to detect or rule out obstructive CAD with quantitative coronary angiography as reference standard. Comparisons of exercise bicycle testing versus CTCA (n = 334), and SPECT versus CTCA (n = 61) were performed. The diagnostic performance of exercise bicycle testing was significantly (P value0.05): 77% (95% CI, 50-92) vs. 82% (95% CI, 56-95). We observed a PPV of 91% (95% CI, 77-97) vs. 93% (95% CI, 81-98); andNPVof 72% (95%, 46-89) vs. 93% (95%, 66-100). SPECT and CTCA yielded higher diagnostic performance compared to traditional exercise bicycle testing for the detection and rule out of obstructive CAD in patients with stable angina
Computed tomography coronary angiography accuracy in women and men at low to intermediate risk of coronary artery disease
Objectives To investigate the diagnostic accuracy of CT coronary angiography (CTCA) in women at low to intermediate pre-test probability of coronary artery disease (CAD) compared with men. Methods In this retrospective study we included symptomatic patients with low to intermediate risk who underwent both invasive coronary angiography and CTCA. Exclusion criteria were previous revascularisation or myocardial infarction. The pre-test probability of CAD was estimated using the Duke risk score. Thresholds of less than 30 % and 30-90 % were used for determining low and intermediate risk, respectively. The diagnostic accuracy of CTCA in detecting obstructive CAD (≥50 % lumen diameter narrowing) was calculated on patient level. P<0.05 was considered significant. Results A total of 570 patients (46 % women [262/570]) were included and stratified as low (women 73 % [80/109]) and intermediate risk (women 39 % [182/461]). Sensitivity, specificity, PPV and NPV were not significantly different in and between women and men at low and intermediate risk. For women vs. me
Multidetector CT for visualization of coronary stents
Whereas the clinical diagnosis of in-stent thrombosis is straightforward, that of in-stent restenosis remains a problem, because although many patients experience chest pain after coronary stent placement, that symptom is secondary to ischemia in only a few. The use of a noninvasive technique to identify such patients for early invasive intervention versus more conservative management is thus highly desirable. Multidetector computed tomography (CT) performed with 16-section scanners recently emerged as such a technique and has overtaken modalities such as electron-beam CT and magnetic resonance imaging as an alternative to conventional angiography for the assessment of instent restenosis. The improved hardware design of the current 64-section CT scanners allows even better delineation of stent struts and lumen. The more reliable criterion of direct lumen visualization thus may be substituted for the presence of distal runoff, which lacks specificity for a determination of in-stent patency because of the possibility of collateral pathways. However, the capability to accurately visualize the in-stent lumen depends partly on knowledge of the causes of artifacts and how they can be compensated for with postprocessing and proper image display settings. In addition, an understanding of the major stent placement techniques used in the treatment of lesions at arterial bifurcations is helpful
Optimal electrocardiographic pulsing windows and heart rate: Effect on image quality and radiation exposure at dual-source coronary CT angiography
Purpose: To determine the optimal width and timing of the electrocardiographic (ECG) pulsing window within the cardiac cycle in relation to heart rate (HR), image quality, and radiation exposure in patients who are suspected of having coronary artery disease. Materials and Methods: The institutional review board approved the study, and all patients gave informed consent. Dual-source computed tomography (CT) was performed in 301 patients (mean HR, 70.1 beats per minute ± 13.3 [standard deviation]; range, 43-112 beats per minute) by using a wide ECG pulsing window (25%-70% of the R-R interval). Data sets were reconstructed in 5% steps from 20%-75% of R-R interval. Image quality was assessed by two observers on a per-segment level and was classified as good or impaired. High-quality data sets w