1,218 research outputs found

    Holographic Anomalous Conductivities and the Chiral Magnetic Effect

    Full text link
    We calculate anomaly induced conductivities from a holographic gauge theory model using Kubo formulas, making a clear conceptual distinction between thermodynamic state variables such as chemical potentials and external background fields. This allows us to pinpoint ambiguities in previous holographic calculations of the chiral magnetic conductivity. We also calculate the corresponding anomalous current three-point functions in special kinematic regimes. We compare the holographic results to weak coupling calculations using both dimensional regularization and cutoff regularization. In order to reproduce the weak coupling results it is necessary to allow for singular holographic gauge field configurations when a chiral chemical potential is introduced for a chiral charge defined through a gauge invariant but non-conserved chiral density. We argue that this is appropriate for actually addressing charge separation due to the chiral magnetic effect.Comment: 17 pages, 1 figure. v2: 18 pages, 1 figure, discussion clarified throughout the text, references added, version accepted for publication in JHE

    Perceptions of graduating students from eight medical schools in Vietnam on acquisition of key skills identified by teachers

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The eight main Vietnamese medical schools recently cooperated to produce a book listing the knowledge, attitudes and skills expected of a graduate, including specification of the required level for each skill. The teaching program should ensure that students can reach that level. The objective of this study was to determine the perception of graduating students on whether they had achieved the level set for a selection of clinical and public health skills as a guide for the schools to adjust either the levels or the teaching.</p> <p>Methods</p> <p>From all eight schools, 1136 of the 1528 final year students completed questionnaires just before completed all the requirements for graduation, a response rate of 87% overall (ranging from 74–99% per school). They rated their own competence on a scale of 0–5 for 129 skills selected from the 557 skills listed in the book, and reported where they thought they had learned them. The scores that the students gave themselves were then compared to the levels proposed by the teachers for each skill. The proportions of the self-assessed achievement to the levels expected by the teachers, means self-assessed scores and the coefficients of variation were calculated to make comparisons among disciplines, among schools and among learning sites.</p> <p>Results</p> <p>Most students felt they had learned most of the skills for key clinical departments to the required level; this varied little among the schools. Self-assessed skill acquisition in public health and minor clinical disciplines was lower and varied more. Sites outside the classroom were especially important for learning skills. The results revealed key similarities and differences between the teachers and the students in their perception about what could be learned and where</p> <p>Conclusion</p> <p>Revising a curriculum for medical schools demands inputs from all stakeholders. Graduating class students can provide valuable feedback on what they have learned in the existing system. Learning objectives should always be checked with students who have followed their study under existing teaching conditions. The information from the graduates helped to identify potential problem areas where either the objectives or the teaching need adjustment.</p

    Anomalies and the chiral magnetic effect in the Sakai-Sugimoto model

    Full text link
    In the chiral magnetic effect an imbalance in the number of left- and right-handed quarks gives rise to an electromagnetic current parallel to the magnetic field produced in noncentral heavy-ion collisions. The chiral imbalance may be induced by topologically nontrivial gluon configurations via the QCD axial anomaly, while the resulting electromagnetic current itself is a consequence of the QED anomaly. In the Sakai-Sugimoto model, which in a certain limit is dual to large-N_c QCD, we discuss the proper implementation of the QED axial anomaly, the (ambiguous) definition of chiral currents, and the calculation of the chiral magnetic effect. We show that this model correctly contains the so-called consistent anomaly, but requires the introduction of a (holographic) finite counterterm to yield the correct covariant anomaly. Introducing net chirality through an axial chemical potential, we find a nonvanishing vector current only before including this counterterm. This seems to imply the absence of the chiral magnetic effect in this model. On the other hand, for a conventional quark chemical potential and large magnetic field, which is of interest in the physics of compact stars, we obtain a nontrivial result for the axial current that is in agreement with previous calculations and known exact results for QCD.Comment: 35 pages, 4 figures, v2: added comments about frequency-dependent conductivity at the end of section 4; references added; version to appear in JHE

    Holographic chiral magnetic spiral

    Full text link
    We study the ground state of baryonic/axial matter at zero temperature chiral-symmetry broken phase under a large magnetic field, in the framework of holographic QCD by Sakai-Sugimoto. Our study is motivated by a recent proposal of chiral magnetic spiral phase that has been argued to be favored against previously studied phase of homogeneous distribution of axial/baryonic currents in terms of meson super-currents dictated by triangle anomalies in QCD. Our results provide an existence proof of chiral magnetic spiral in strong coupling regime via holography, at least for large axial chemical potentials, whereas we don't find the phenomenon in the case of purely baryonic chemical potential.Comment: 24 pages, 15 figure

    Tailoring the atomic structure of graphene nanoribbons by STM lithography

    Full text link
    The practical realization of nano-scale electronics faces two major challenges: the precise engineering of the building blocks and their assembly into functional circuits. In spite of the exceptional electronic properties of carbon nanotubes only basic demonstration-devices have been realized by time-consuming processes. This is mainly due to the lack of selective growth and reliable assembly processes for nanotubes. However, graphene offers an attractive alternative. Here we report the patterning of graphene nanoribbons (GNRs) and bent junctions with nanometer precision, well-defined widths and predetermined crystallographic orientations allowing us to fully engineer their electronic structure using scanning tunneling microscope (STM) lithography. The atomic structure and electronic properties of the ribbons have been investigated by STM and tunneling spectroscopy measurements. Opening of confinement gaps up to 0.5 eV, allowing room temperature operation of GNR-based devices, is reported. This method avoids the difficulties of assembling nano-scale components and allows the realization of complete integrated circuits, operating as room temperature ballistic electronic devices.Comment: 8 pages text, 5 figures, Nature Nanotechnology, in pres

    Perceptions and behaviors related to hand hygiene for the prevention of H1N1 influenza transmission among Korean university students during the peak pandemic period

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This study was performed to better assess the perceptions, motivating factors, and behaviors associated with the use of hand washing to prevent H1N1 influenza transmission during the peak pandemic period in Korea.</p> <p>Methods</p> <p>A cross-sectional survey questionnaire was completed by 942 students at a university campus in Suwon, Korea, between December 1 and 8, 2009. The survey included questions regarding individual perceptions, motivating factors, and behaviors associated with hand washing for the prevention of H1N1 influenza transmission.</p> <p>Results</p> <p>Compared to one year prior, 30.3% of participants reported increasing their hand washing frequency. Female students were more likely to practice more frequent hand washing. Women also perceived the effectiveness of hand washing to be lower, and illness severity and personal susceptibility to H1N1 infection to be higher. Study participants who were female (OR: 1.79-3.90) who perceived of hand washing to be effective (OR: 1.34-12.15) and illness severity to be greater (OR: 1.00-3.12) washed their hands more frequently.</p> <p>Conclusions</p> <p>Korean students increased their frequency of hand hygiene practices during the pandemic, with significant gender differences existing in the attitudes and behaviors related to the use of hand hygiene as a means of disease prevention. Here, the factors that affected hand washing behavior were similar to those identified at the beginning of the H1N1 or SARS pandemics, suggesting that public education campaigns regarding hand hygiene are effective in altering individual hand hygiene habits during the peak periods of influenza transmission.</p

    Extraperitoneal urine leak after renal transplantation: the role of radionuclide imaging and the value of accompanying SPECT/CT - a case report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The differentiation of the nature of a fluid collection as a complication of kidney transplantation is important for management and treatment planning. Early and delayed radionuclide renography can play an important role in the evaluation of a urine leak. However, it is sometimes limited in the evaluation of the exact location and extent of a urine leak.</p> <p>Case Presentation</p> <p>A 71-year-old male who had sudden anuria, scrotal swelling and elevated creatinine level after cadaveric renal transplantation performed Tc-99 m MAG3 renography to evaluate the renal function, followed by an ultrasound which was unremarkable. An extensive urine leak was evident on the planar images. However, an exact location of the urine leak was unknown. Accompanying SPECT/CT images confirmed a urine leak extending from the lower aspect of the transplant kidney to the floor of the pelvic cavity, presacral region and the scrotum via right inguinal canal as well as to the right abdominal wall.</p> <p>Conclusions</p> <p>Renal scintigraphy is very useful to detect a urine leak after renal transplantation. However, planar imaging is sometimes limited in evaluating the anatomical location and extent of a urine leak accurately. In that case accompanying SPECT/CT images are very helpful and valuable to evaluate the anatomical relationships exactly.</p

    Orbifold equivalence for finite density QCD and effective field theory

    Full text link
    In the large N_c limit, some apparently different gauge theories turn out to be equivalent due to large N_c orbifold equivalence. We use effective field theory techniques to explore orbifold equivalence, focusing on the specific case of a recently discovered relation between an SO(2N_c) gauge theory and QCD. The equivalence to QCD has been argued to hold at finite baryon chemical potential, \mu_B, so long as one deforms the SO(2N_c) theory by certain "double-trace" terms. The deformed SO(2N_c) theory can be studied without a sign problem in the chiral limit, in contrast to SU(N_c) QCD at finite \mu_B. The purpose of the double-trace deformation in the SO(2N_c) theory is to prevent baryon number symmetry from breaking spontaneously at finite density, which is necessary for the equivalence to large N_c QCD to be valid. The effective field theory analysis presented here clarifies the physical significance of double-trace deformations, and strongly supports the proposed equivalence between the deformed SO(2N_c) theory and large N_c QCD at finite density.Comment: 39 pages, 5 figures, 2 tables. v2: Minor typo fixes and clarification

    Control and Characterization of Individual Grains and Grain Boundaries in Graphene Grown by Chemical Vapor Deposition

    Get PDF
    The strong interest in graphene has motivated the scalable production of high quality graphene and graphene devices. Since large-scale graphene films synthesized to date are typically polycrystalline, it is important to characterize and control grain boundaries, generally believed to degrade graphene quality. Here we study single-crystal graphene grains synthesized by ambient CVD on polycrystalline Cu, and show how individual boundaries between coalescing grains affect graphene's electronic properties. The graphene grains show no definite epitaxial relationship with the Cu substrate, and can cross Cu grain boundaries. The edges of these grains are found to be predominantly parallel to zigzag directions. We show that grain boundaries give a significant Raman "D" peak, impede electrical transport, and induce prominent weak localization indicative of intervalley scattering in graphene. Finally, we demonstrate an approach using pre-patterned growth seeds to control graphene nucleation, opening a route towards scalable fabrication of single-crystal graphene devices without grain boundaries.Comment: New version with additional data. Accepted by Nature Material
    corecore