64 research outputs found

    Neonatesā€™ responses to repeated exposure to a still face

    Get PDF
    The main aims of the study were to examine whether human neonates' responses to communication disturbance modelled by the still-face paradigm were stable and whether their responses were affected by their previous experience with the still-face paradigm.The still face procedure, as a laboratory model of interpersonal stress, was administered repeatedly, twice, to 84 neonates (0 to 4 day olds), with a delay of an average of 1.25 day.Frame-by-frame analysis of the frequency and duration of gaze, distressed face, crying, sleeping and sucking behaviours showed that the procedure was stressful to them both times, that is, the still face effect was stable after repeated administration and newborns consistently responded to such nonverbal violation of communication. They averted their gaze, showed distress and cried more during the still-face phase in both the first and the second administration. They also showed a carry-over effect in that they continued to avert their gaze and displayed increased distress and crying in the first reunion period, but their gaze behaviour changed with experience, in the second administration. While in the first administration the babies continued averting their gaze even after the stressful still-face phase was over, this carry-over effect disappeared in the second administration, and the babies significantly increased their gaze following the still-face phase.After excluding explanations of fatigue, habituation and random effects, a self-other regulatory model is discussed as a possible explanation for this pattern

    Robust Biomarkers: Methodologically Tracking Causal Processes in Alzheimerā€™s Measurement

    Get PDF
    In biomedical measurement, biomarkers are used to achieve reliable prediction of, and useful causal information about patient outcomes while minimizing complexity of measurement, resources, and invasiveness. A biomarker is an assayable metric that discloses the status of a biological process of interest, be it normative, pathophysiological, or in response to intervention. The greatest utility from biomarkers comes from their ability to help clinicians (and researchers) make and evaluate clinical decisions. In this paper we discuss a specific methodological use of clinical biomarkers in pharmacological measurement: Some biomarkers, called ā€˜surrogate markersā€™, are used to substitute for a clinically meaningful endpoint corresponding to events and their penultimate risk factors. We confront the reliability of clinical biomarkers that are used to gather information about clinically meaningful endpoints. Our aim is to present a systematic methodology for assessing the reliability of multiple surrogate markers (and biomarkers in general). To do this we draw upon the robustness analysis literature in the philosophy of science and the empirical use of clinical biomarkers. After introducing robustness analysis we present two problems with biomarkers in relation to reliability. Next, we propose an intervention-based robustness methodology for organizing the reliability of biomarkers in general. We propose three relevant conditions for a robust methodology for biomarkers: (R1) Intervention-based demonstration of partial independence of modes: In biomarkers partial independence can be demonstrated through exogenous interventions that modify a process some number of ā€œstepsā€ removed from each of the markers. (R2) Comparison of diverging and converging results across biomarkers: By systematically comparing partially-independent biomarkers we can track under what conditions markers fail to converge in results, and under which conditions they successfully converge. (R3) Information within the context of theory: Through a systematic cross-comparison of the markers we can make causal conclusions as well as eliminate competing theories. We apply our robust methodology to currently developing Alzheimerā€™s research to show its usefulness for making causal conclusions

    Clinical symptoms, signs and tests for identification of impending and current water-loss dehydration in older people (Review)

    Get PDF
    BackgroundThere is evidence that water-loss dehydration is common in older people and associated with many causes of morbidity and mortality.However, it is unclear what clinical symptoms, signs and tests may be used to identify early dehydration in older people, so that support can be mobilised to improve hydration before health and well-being are compromised.ObjectivesTo determine the diagnostic accuracy of state (one time), minimally invasive clinical symptoms, signs and tests to be used as screeningtests for detecting water-loss dehydration in older people by systematically reviewing studies that have measured a reference standard and at least one index test in people aged 65 years and over. Water-loss dehydration was defined primarily as including everyone with either impending or current water-loss dehydration (including all those with serum osmolality ā‰„ 295 mOsm/kg as being dehydrated).Search methodsStructured search strategies were developed for MEDLINE (OvidSP), EMBASE (OvidSP), CINAHL, LILACS, DARE and HTAdatabases (The Cochrane Library), and the International Clinical Trials Registry Platform (ICTRP). Reference lists of included studiesand identified relevant reviews were checked. Authors of included studies were contacted for details of further studies.Selection criteriaTitles and abstracts were scanned and all potentially relevant studies obtained in full text. Inclusion of full text studies was assessed independently in duplicate, and disagreements resolved by a third author. We wrote to authors of all studies that appeared to have collected data on at least one reference standard and at least one index test, and in at least 10 people aged ā‰„ 65 years, even where no comparative analysis has been published, requesting original dataset so we could create 2 x 2 tables.Data collection and analysis.Diagnostic accuracy of each test was assessed against the best available reference standard for water-loss dehydration (serum or plasma osmolality cut-offā‰„295mOsm/kg, serumosmolarity or weight change) within each study. For each index test study data were presented in forest plots of sensitivity and specificity. The primary target condition was water-loss dehydration (including either impending or current water-loss dehydration). Secondary target conditions were intended as current (> 300 mOsm/kg) and impending (295 to 300 mOsm/kg) water-loss dehydration, but restricted to current dehydration in the final review.We conducted bivariate random-effects meta-analyses (Stata/IC, StataCorp) for index tests where there were at least four studies and study datasets could be pooled to construct sensitivity and specificity summary estimates. We assigned the same approach for index tests with continuous outcome data for each of three pre-specified cut-off points investigated.Pre-set minimum sensitivity of a useful test was 60%, minimum specificity 75%. As pre-specifying three cut-offs for each continuoustest may have led to missing a cut-off with useful sensitivity and specificity, we conducted post-hoc exploratory analyses to createreceiver operating characteristic (ROC) curves where there appeared some possibility of a useful cut-off missed by the original three.These analyses enabled assessment of which tests may be worth assessing in further research. A further exploratory analysis assessed the value of combining the best two index tests where each had some individual predictive ability.Main resultsThere were few published studies of the diagnostic accuracy of state (one time), minimally invasive clinical symptoms, signs or tests tobe used as screening tests for detecting water-loss dehydration in older people. Therefore, to complete this review we sought, analysed and included raw datasets that included a reference standard and an index test in people aged ā‰„ 65 years.We included three studies with published diagnostic accuracy data and a further 21 studies provided datasets that we analysed. Weassessed 67 tests (at three cut-offs for each continuous outcome) for diagnostic accuracy of water-loss dehydration (primary targetcondition) and of current dehydration (secondary target condition).Only three tests showed any ability to diagnose water-loss dehydration (including both impending and current water-loss dehydration) as stand-alone tests: expressing fatigue (sensitivity 0.71 (95% CI 0.29 to 0.96), specificity 0.75 (95% CI 0.63 to 0.85), in one study with 71 participants, but two additional studies had lower sensitivity); missing drinks between meals (sensitivity 1.00 (95% CI 0.59 to 1.00), specificity 0.77 (95% CI 0.64 to 0.86), in one study with 71 participants) and BIA resistance at 50 kHz (sensitivities 1.00 (95% CI 0.48 to 1.00) and 0.71 (95% CI 0.44 to 0.90) and specificities of 1.00 (95% CI 0.69 to 1.00) and 0.80 (95% CI 0.28 to 0.99) in 15 and 22 people respectively for two studies, but with sensitivities of 0.54 (95% CI 0.25 to 0.81) and 0.69 (95% CI 0.56 to 0.79) and specificities of 0.50 (95% CI 0.16 to 0.84) and 0.19 (95% CI 0.17 to 0.21) in 21 and 1947 people respectively in two other studies). In post-hoc ROC plots drinks intake, urine osmolality and axillial moisture also showed limited diagnostic accuracy. No test was consistently useful in more than one study.Combining two tests so that an individual both missed some drinks between meals and expressed fatigue was sensitive at 0.71 (95%CI 0.29 to 0.96) and specific at 0.92 (95% CI 0.83 to 0.97).There was sufficient evidence to suggest that several stand-alone tests often used to assess dehydration in older people (including fluid intake, urine specific gravity, urine colour, urine volume, heart rate, dry mouth, feeling thirsty and BIA assessment of intracellular water or extracellular water) are not useful, and should not be relied on individually as ways of assessing presence or absence of dehydration in older people.No tests were found consistently useful in diagnosing current water-loss dehydration.Authorsā€™ conclusionsThere is limited evidence of the diagnostic utility of any individual clinical symptom, sign or test or combination of tests to indicatewater-loss dehydration in older people. Individual tests should not be used in this population to indicate dehydration; they miss a highproportion of people with dehydration, and wrongly label those who are adequately hydrated.Promising tests identified by this review need to be further assessed, as do new methods in development. Combining several tests may improve diagnostic accuracy

    Cryo-EM structures of the human glutamine transporter SLC1A5 (ASCT2) in the outward-facing conformation

    Full text link
    Alanine-serine-cysteine transporter 2 (ASCT2, SLC1A5) is the primary transporter of glutamine in cancer cells and regulates the mTORC1 signaling pathway. The SLC1A5 function involves finely tuned orchestration of two domain movements that include the substrate-binding transport domain and the scaffold domain. Here, we present cryo-EM structures of human SLC1A5 and its complex with the substrate, L-glutamine in an outward-facing conformation. These structures reveal insights into the conformation of the critical ECL2a loop which connects the two domains, thus allowing rigid body movement of the transport domain throughout the transport cycle. Furthermore, the structures provide new insights into substrate recognition, which involves conformational changes in the HP2 loop. A putative cholesterol binding site was observed near the domain interface in the outward-facing state. Comparison with the previously determined inward-facing structure of SCL1A5 provides a basis for a more integrated understanding of substrate recognition and transport mechanism in the SLC1 family

    Cryo-EM structures of the human glutamine transporter SLC1A5 (ASCT2) in the outward-facing conformation

    Full text link
    Alanine-serine-cysteine transporter 2 (ASCT2, SLC1A5) is the primary transporter of glutamine in cancer cells and regulates the mTORC1 signaling pathway. The SLC1A5 function involves finely tuned orchestration of two domain movements that include the substrate-binding transport domain and the scaffold domain. Here, we present cryo-EM structures of human SLC1A5 and its complex with the substrate, L-glutamine in an outward-facing conformation. These structures reveal insights into the conformation of the critical ECL2a loop which connects the two domains, thus allowing rigid body movement of the transport domain throughout the transport cycle. Furthermore, the structures provide new insights into substrate recognition, which involves conformational changes in the HP2 loop. A putative cholesterol binding site was observed near the domain interface in the outward-facing state. Comparison with the previously determined inward-facing structure of SCL1A5 provides a basis for a more integrated understanding of substrate recognition and transport mechanism in the SLC1 family
    • ā€¦
    corecore