111 research outputs found

    Thoracoscopic resection of a paraaortic bronchogenic cyst

    Get PDF
    Bronchogenic mediastinal cysts (BMC) represent 18% of primitive mediastinal tumors and the most frequent cystic lesions in this area. Nowadays, BMC are usually treated by VATS. However, the presence of major adhesions to vital structures is often considered as an unfavourable condition for thoracoscopic treatment. The authors report the thoracoscopic treatment of a BMC having dense adhesions to the aortic arch. Diagnosis and surgical treatment is described. Review of the literature and surgical options on this topic are discussed

    Entwicklung der Analytischen Chemie

    No full text

    Application of disposable plastic syringes in analytical chemistry

    No full text

    MEDIUM FORMAT CAMERA EVALUATION BASED ON THE LATEST PHASE ONE TECHNOLOGY

    No full text
    In early 2016, Phase One Industrial launched a new high resolution camera with a 100 MP CMOS sensor. CCD sensors excel at ISOs up to 200, but in lower light conditions, exposure time must be increased and Forward Motion Compensation (FMC) has to be employed to avoid smearing the images. The CMOS sensor has an ISO range of up to 6400, which enables short exposures instead of using FMC. This paper aims to evaluate the strengths of each of the sensor types based on real missions over a test field in Speyer, Germany, used for airborne camera calibration. The test field area has about 30 Ground Control Points (GCPs), which enable a perfect scenario for a proper geometric evaluation of the cameras. The test field includes both a Siemen star and scale bars to show any blurring caused by forward motion. The result of the comparison showed that both cameras offer high accuracy photogrammetric results with post processing, including triangulation, calibration, orthophoto and DEM generation. The forward motion effect can be compensated by a fast shutter speed and a higher ISO range of the CMOS-based camera. The results showed no significant differences between cameras

    CRITICAL COMPARISON OF ICP-OES, XRF AND FLUORINE VOLATILIZATION-FTIR SPECTROMETRY FOR THE RELIABLE DETERMINATION OF THE SILICON MAIN CONSTITUENT IN CERAMIC MATERIALS

    No full text
    or the optimization of preparation processes for ceramic powders and compacts by pyrolysis of inorganic polymers, the intermediate and final products have to be monitored by in-situ analysis (in its original place) for main, subsidiary and trace components. In the determination of silicon in Si-N-C- based ceramic samples by ICP-OES after pressurized decomposition at temperatures between 220 degrees-250 degrees C too low concentrations of Si were found. Completely independent analytical procedures were applied to trace systematic errors, i.e. XRF after decomposition of the sample in a metaborate/boric acid melt and FTIR-spectrometry after reaction of the sample with fluorine. The low recoveries of Si were found to be due to losses, which amount up to 25% depending on the temperature and time applied for the pressurized decomposition. With the latter two procedures Si can be determined in the %-range with a relative standard deviation of less than or equal to 0.4% and less than or equal to 0.2%, respectively

    A partially mechanized system for the combustion of organic samples in a stream of oxygen with quantitative recovery of the trace elements.

    No full text
    Ein teilmechanisiertes aus Quarz bestehendes System (Trace-0-Mat) wird beschrieben, das die vollständige Mineralisation fester organischer oder biologischer Proben bis zu Mengen von 1 g gestattet. Die Verbrennung findet dabei in reinem Sauerstoff in einer sehr kleinen Verbrennungskammer (etwa 75 cm3) statt, so daß anschließend die metallischen und nichtmetallischen Spurenelemente mit hoher Zuverlässigkeit bestimmt werden können. Die steuerbare Veraschung wird durch ein System von IR-Strahlern gestartet. Alle flüchtigen Spurenelemente (z. B. Hg, Se, Te, As, Sb, I) werden zusammen mit den Verbrennungsprodukten in einem Kühlsystem kondensiert, das mit flüssigem Stickstoff gefüllt und über der Verbrennungskammer angeordnet ist. Die sich an den gekühlten Flächen befindlichen flüchtigen sowie die in der Asche vorhandenen nichtflüchtigen Elemente werden durch Rückflußbehandlung mit einer kleinen Säuremenge (2 ml) gelöst und in einem Quarzglas unterhalb der Verbrennungskammer gesammelt. Die Wiederfindung der Elemente nach dem Aufschlußprozeß (50–60 min) wurde mit Hilfe von 7 NBS-Referenzmaterialien für folgende Elemente geprüft: B, Cr, Cu, Fe, Mn, Zn (ICP-Emissionsspektrometrie), Cd, Pb (ETA-AAS), Hg (AAS-Kaltdampftechnik), As (AAS-Hydridmethode) und Se (Röntgenfluorescenz). Es ergab sich sehr gute Übereinstimmung mit den zertifizierten Werten. Diese neue und sehr allgemein anwendbare Aufschlußmethode weist nicht nur geringe Blindwerte auf, sondern vermeidet auch wesentliche Verluste der zu bestimmenden Elemente durch Verflüchtigung, Adsorption oder Zusammenbacken an der Quarzoberfläche. Durch die einfache Handhabung der Apparatur ist eine zuverlässige Bestimmung von Spurenelementen im μg/g- und ng/g-Bereich für die meisten nichtflüchtigen organischen Matrices gewährleistet. &nbsp
    • …
    corecore