179 research outputs found

    Blood pressure and physical activity : time to move (on)

    Get PDF

    Drug adherence in chronic kidney diseases and dialysis.

    Get PDF
    Poor long-term adherence and persistence to drug therapy is universally recognized as one of the major clinical issues in the management of chronic diseases, and patients with renal diseases are also concerned by this important phenomenon. Chronic kidney disease (CKD) patients belong to the group of subjects with one of the highest burdens of daily pill intake with up to >20 pills per day depending on the severity of their disease. The purpose of the present review is to discuss the difficulties encountered by nephrologists in diagnosing and managing poor adherence and persistence in CKD patients including in patients receiving maintenance dialysis. Our review will also attempt to provide some clues and new perspectives on how drug adherence could actually be addressed and possibly improved. Working on drug adherence may look like a long and tedious path, but physicians and healthcare providers should always be aware that drug adherence is in general much lower than what they may think and that there are many ways to improve and support drug adherence and persistence so that renal patients obtain the full benefits of their treatments

    Clinical determinants of adrenal vein sampling success

    Get PDF
    Background: Primary aldosteronism (PA) is one of the most prevalent forms of secondary hypertension, which may be cured by unilateral adrenalectomy. Adrenal vein sampling (AVS) is considered the gold-standard procedure for distinction between bilateral and unilateral aldosterone hypersecretion. However, the procedure is viewed as a technical challenge. The objectives of this study were to define the success rate of AVS, and its clinical determinants, and to compare the accuracy of high-resolution adrenal computed tomography (CT) with AVS. Methods: In this single-centre retrospective study, patients with biologically proven PA who were referred for AVS between 2009 and 2014 were included. Adrenal vein catheterisation was considered selective if the selectivity index (adrenal vein / inferior vena cava cortisol) was ≥2. Results: Data from 68 patients (48% women) were available. The success rate of catheterisation in bilateral AVS was 60% (41/68). The significant clinical determinants of success were male sex (r = 0.35, p = 0.004), a higher body mass index (BMI) (r = 0.54, p = 0.001) and plasma creatinine (r = 0.25, p = 0.048) in univariate analysis. In multivariate linear regression analysis, only BMI was associated with success (coefficient = 0.049, p = 0.004). CT was discordant with AVS in 53% of patients, and would have resulted in inappropriate adrenalectomy in 43% of the patients and inappropriate exclusion from surgery in 10% of the cases. Conclusion: Clinical characteristics such as BMI and sex may influence the success rate of AVS. The inaccuracy of CT may result in inappropriate treatment proposals if the indication for surgical intervention is based on CT only

    Circadian glomerular function: from physiology to molecular and therapeutical aspects.

    Get PDF
    Life on earth is rhythmic by essence due to day/night alternation, and many biological processes are also cyclic. The kidney has a special role in the organism, controlling electrolytes and water balance, blood pressure, elimination of metabolic waste and xenobiotics and the production of several hormones. The kidney is submitted to changes throughout 24 h with periods of intense activity followed by calmer periods. Filtration, reabsorption and secretion are the three components determining renal function. Here, we review circadian changes related to glomerular function and proteinuria and emphasize the role of the clock in these processes

    Validation of the optical Aktiia bracelet in different body positions for the persistent monitoring of blood pressure.

    Get PDF
    The diagnosis of hypertension and the adjustment of antihypertensive drugs are evolving from isolated measurements performed at the physician offices to the full phenotyping of patients in real-life conditions. Indeed, the strongest predictor of cardiovascular risk comes from night measurements. The aim of this study was to demonstrate that a wearable device (the Aktiia Bracelet) can accurately estimate BP in the most common body positions of daily life and thus become a candidate solution for the BP phenotyping of patients. We recruited 91 patients with BP ranging from low to hypertensive levels and compared BP values from the Aktiia Bracelet against auscultatory reference values for 4 weeks according to an extended ISO 81060-2 protocol. After initializing on day one, the observed means and standard deviations of differences for systolic BP were of 0.46 ± 7.75 mmHg in the sitting position, - 2.44 ± 10.15 mmHg in the lying, - 3.02 ± 6.10 mmHg in the sitting with the device on the lap, and - 0.62 ± 12.51 mmHg in the standing position. Differences for diastolic BP readings were respectively of 0.39 ± 6.86 mmHg, - 1.93 ± 7.65 mmHg, - 4.22 ± 6.56 mmHg and - 4.85 ± 9.11 mmHg. This study demonstrates that a wearable device can accurately estimate BP in the most common body positions compared to auscultation, although precision varies across positions. While wearable persistent BP monitors have the potential to facilitate the identification of individual BP phenotypes at scale, their prognostic value for cardiovascular events and its association with target organ damage will need cross-sectional and longitudinal studies. Deploying this technology at a community level may be also useful to drive public health interventions against the epidemy of hypertension

    Validation of the optical Aktiia bracelet in different body positions for the persistent monitoring of blood pressure.

    Get PDF
    The diagnosis of hypertension and the adjustment of antihypertensive drugs are evolving from isolated measurements performed at the physician offices to the full phenotyping of patients in real-life conditions. Indeed, the strongest predictor of cardiovascular risk comes from night measurements. The aim of this study was to demonstrate that a wearable device (the Aktiia Bracelet) can accurately estimate BP in the most common body positions of daily life and thus become a candidate solution for the BP phenotyping of patients. We recruited 91 patients with BP ranging from low to hypertensive levels and compared BP values from the Aktiia Bracelet against auscultatory reference values for 4 weeks according to an extended ISO 81060-2 protocol. After initializing on day one, the observed means and standard deviations of differences for systolic BP were of 0.46 ± 7.75 mmHg in the sitting position, - 2.44 ± 10.15 mmHg in the lying, - 3.02 ± 6.10 mmHg in the sitting with the device on the lap, and - 0.62 ± 12.51 mmHg in the standing position. Differences for diastolic BP readings were respectively of 0.39 ± 6.86 mmHg, - 1.93 ± 7.65 mmHg, - 4.22 ± 6.56 mmHg and - 4.85 ± 9.11 mmHg. This study demonstrates that a wearable device can accurately estimate BP in the most common body positions compared to auscultation, although precision varies across positions. While wearable persistent BP monitors have the potential to facilitate the identification of individual BP phenotypes at scale, their prognostic value for cardiovascular events and its association with target organ damage will need cross-sectional and longitudinal studies. Deploying this technology at a community level may be also useful to drive public health interventions against the epidemy of hypertension

    Blood Pressure and Renal Responses to Orthostatic Stress Before and After Radiofrequency Renal Denervation in Patients with Resistant Hypertension.

    Get PDF
    In patients with resistant hypertension, renal denervation (RDN) studies have mainly focused their outcomes on blood pressure (BP). The aim of this study was to evaluate the long-term effect of RDN on neurohormonal profiles, renal hemodynamics and sodium excretion in a resting state and during stress induced by lower body negative pressure (LBNP). This was a single center prospective observational study. Norepinephrine, plasma renin activity (PRA), glomerular filtration rate (GFR), renal plasma flow (RPF) and sodium excretion were measured in unstimulated conditions (rest) and after one hour of LBNP at three different time points: before (M0), one (M1) and twelve months (M12) after RDN. Thirteen patients with resistant hypertension were included. In the resting state, no differences were observed in norepinephrine, PRA, sodium excretion and mean BP levels after RDN. GFR (78 ± 32 ml/min at M0 vs 66 ± 26 ml/min at M12 ( <i>p</i> = 0.012) and filtration fraction (22.6 ±5.4% at M0 vs 15.1 ±5.3% at M12 ( <i>p</i> = 0.002)) both decreased after RDN. During LBNP, the magnitude of the mean BP increase was reduced from +6.8 ± 6.6 mm Hg at M0 to +2.3 ± 1.3 mm Hg at M12 ( <i>p</i> = 0.005). The LBNP-induced increase in norepinephrine and decrease in GFR and sodium excretion observed before RDN were blunted after the procedure. A decrease in GFR and filtration fraction was observed one year after RDN. In addition, our results suggest that RDN blunts not only the norepinephrine but also the mean BP, the GFR and the sodium excretion responses to an orthostatic stress one year after the intervention. NCT01734096
    corecore