52 research outputs found

    Flow cytometry as a rapid analytical tool to determine physiological responses to changing O2 and iron concentration by Magnetospirillum gryphiswaldense strain MSR-1

    Get PDF
    Magnetotactic bacteria (MTB) are a diverse group of bacteria that synthesise magnetosomes, magnetic membrane-bound nanoparticles that have a variety of diagnostic, clinical and biotechnological applications. We present the development of rapid methods using flow cytometry to characterize several aspects of the physiology of the commonly-used MTB Magnetospirillum gryphiswaldense MSR-1. Flow cytometry is an optical technique that rapidly measures characteristics of individual bacteria within a culture, thereby allowing determination of population heterogeneity and also permitting direct analysis of bacteria. Scatter measurements were used to measure and compare bacterial size, shape and morphology. Membrane permeability and polarization were measured using the dyes propidium iodide and bis-(1,3-dibutylbarbituric acid) trimethine oxonol to determine the viability and ‘health’ of bacteria. Dyes were also used to determine changes in concentration of intracellular free iron and polyhydroxylakanoate (PHA), a bacterial energy storage polymer. These tools were then used to characterize the responses of MTB to different O2 concentrations and iron-sufficient or iron-limited growth. Rapid analysis of MTB physiology will allow development of bioprocesses for the production of magnetosomes, and will increase understanding of this fascinating and useful group of bacteria

    Phenotypic Variation and Bistable Switching in Bacteria

    Get PDF
    Microbial research generally focuses on clonal populations. However, bacterial cells with identical genotypes frequently display different phenotypes under identical conditions. This microbial cell individuality is receiving increasing attention in the literature because of its impact on cellular differentiation, survival under selective conditions, and the interaction of pathogens with their hosts. It is becoming clear that stochasticity in gene expression in conjunction with the architecture of the gene network that underlies the cellular processes can generate phenotypic variation. An important regulatory mechanism is the so-called positive feedback, in which a system reinforces its own response, for instance by stimulating the production of an activator. Bistability is an interesting and relevant phenomenon, in which two distinct subpopulations of cells showing discrete levels of gene expression coexist in a single culture. In this chapter, we address techniques and approaches used to establish phenotypic variation, and relate three well-characterized examples of bistability to the molecular mechanisms that govern these processes, with a focus on positive feedback.

    IgG Seroconversion and Pathophysiology in Severe Acute Respiratory Syndrome Coronavirus 2 Infection.

    Get PDF
    We investigated the dynamics of seroconversion in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. During March 29–May 22, 2020, we collected serum samples and associated clinical data from 177 persons in London, UK, who had SARS-CoV-2 infection. We measured IgG against SARS-CoV-2 and compared antibody levels with patient outcomes, demographic information, and laboratory characteristics. We found that 2.0%–8.5% of persons did not seroconvert 3–6 weeks after infection. Persons who seroconverted were older, were more likely to have concurrent conditions, and had higher levels of inflammatory markers. Non-White persons had higher antibody concentrations than those who identified as White; these concentrations did not decline during follow-up. Serologic assay results correlated with disease outcome, race, and other risk factors for severe SARS-CoV-2 infection. Serologic assays can be used in surveillance to clarify the duration and protective nature of humoral responses to SARS-CoV-2 infection

    Comparing recovering efficiency of immunomagnetic separation and centrifugation of mycobacteria in metalworking fluids

    Full text link
    The accurate detection and enumeration of Mycobacterium immunogenum in metalworking fluids (MWFs) is imperative from an occupational health and industrial fluids management perspective. We report here a comparison of immunomagnetic separation (IMS) coupled to flow-cytometric enumeration, with traditional centrifugation techniques for mycobacteria in a semisynthetic MWF. This immunolabeling involves the coating of laboratory-synthesized nanometer-scale magnetic particles with protein A, to conjugate a primary antibody (Ab), specific to Mycobacterium spp. By using magnetic separation and flow-cytometric quantification, this approach enabled much higher recovery efficiency and fluorescent light intensities in comparison to the widely applied centrifugation technique. This IMS technique increased the cell recovery efficiency by one order of magnitude, and improved the fluorescence intensity of the secondary Ab conjugate by 2-fold, as compared with traditional techniques. By employing nanometer-scale magnetic particles, IMS was found to be compatible with flow cytometry (FCM), thereby increasing cell detection and enumeration speed by up to two orders of magnitude over microscopic techniques. Moreover, the use of primary Ab conjugated magnetic nanoparticles showed better correlation between epifluorescent microscopy counts and FCM analysis than that achieved using traditional centrifugation techniques. The results strongly support the applicability of the flow-cytometric IMS for microbial detection in complex matrices.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/47949/1/10295_2005_Article_238.pd
    corecore