7 research outputs found

    Antibiotic use for upper respiratory tract infections in children: A cross-sectional survey of knowledge, attitudes, and practices (KAP) of parents in Greece

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Upper respiratory tract infections (URTIs) are common in children. The cause of URTIs is usually viral, but parents' attitudes often contribute to inappropriate prescription of antibiotics, promoting antibiotic resistance. The objective of this study was to document and analyse parental beliefs on antibiotic use for children with URTIs in Greece, a country with high levels of antibiotic use and antibiotic resistance.</p> <p>Methods</p> <p>A knowledge-attitude-practice questionnaire was developed and distributed to Greek parents caring for children who were 5-6 years old, between January and July of the same school year. The sample of the study contained parents from all geographic areas of Greece.</p> <p>Results</p> <p>The majority of Greek parents (80%) believed that UTRIs are mostly self-limited, although 74% of them expected to receive antibiotics when such a diagnosis was given. Earache was the most common reason for which parents expected antibiotics (45%). Greek parents rarely gave antibiotics to their children without medical advice (10%) and most (88%) believed that unnecessary antibiotic use drives antibiotic resistance and they were happy to receive symptomatic therapy if instructed by their physician. Almost 70% of parents confused antibiotics with other medicines used for symptomatic therapy for a child with URTI.</p> <p>Conclusion</p> <p>Greek parents have a trusted relationship with their paediatrician and rarely give antibiotics without medical advice, indicating that parents contribute less than expected to antibiotic misuse. Parents also appreciate the benign course of most URTIs and the fact that unnecessary antibiotic use is harmful. More time needs to be invested in educating mostly physicians on the potential benefit from reducing antibiotic prescribing for children with URTI.</p

    Hygiene inspections on passenger ships in Europe - an overview

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hygiene inspections on passenger ships are important for the prevention of communicable diseases. The European Union (EU) countries conduct hygiene inspections on passenger ships in order to ensure that appropriate measures have been taken to eliminate potential sources of contamination which could lead to the spread of communicable diseases. This study was implemented within the framework of the EU SHIPSAN project and it investigates the legislation applied and practices of hygiene inspections of passenger ships in the EU Member States (MS) and European Free Trade Association countries.</p> <p>Methods</p> <p>Two questionnaires were composed and disseminated to 28 countries. A total of 92 questionnaires were completed by competent authorities responsible for hygiene inspections (n = 48) and the creation of legislation (n = 44); response rates were 96%, and 75.9%, respectively.</p> <p>Results</p> <p>Out of the 48 responding authorities responsible for hygiene inspections, a routine programme was used by 19 (39.6%) of these to conduct inspections of ships on national voyages and by 26 (54.2%) for ships on international voyages. Standardised inspection forms are used by 59.1% of the authorities. A scoring inspection system is applied by five (11.6%) of the 43 responding authorities. Environmental sampling is conducted by 84.1% of the authorities (37 out of 44). The inspection results are collected and analysed by 54.5% (24 out of 44) of the authorities, while 9 authorities (20.5%) declared that they publish the results. Inspections are conducted during outbreak investigations by 75% and 70.8% of the authorities, on ships on national and international voyages, respectively. A total of 31 (64.6%) and 39 (81.3%) authorities conducted inspections during complaint investigations on ships on international and on national voyages, respectively. Port-to-port communication between the national port authorities was reported by 35.4% (17 out of 48) of the responding authorities and 20.8% (10 out of 48) of the port authorities of other countries.</p> <p>Conclusion</p> <p>This study revealed a diversity of approaches and practices in the conduct of inspections, differences in the qualifications/knowledge/experience of inspectors, the legislation applied during inspections, and the lack of communication and training among many EU countries. An integrated European inspection programme involving competent expert inspectors in each EU Member States and special training for ship hygiene delivered to crew members and inspectors would help to minimize the risk of communicable diseases. Common inspection tools at a European level for hygiene inspection practices and port-to-port communication are needed.</p

    Development and assessment of a questionnaire for a descriptive cross – sectional study concerning parents' knowledge, attitudes and practises in antibiotic use in Greece

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Upper Respiratory Infections (URIs) are common in children. The cause is usually viral, but parents' attitude often contributes to inappropriate antibiotic prescribing, promoting antibiotic resistance. The objective is to describe the process of developing a questionnaire to assess parents' Knowledge, Attitude and Practices (KAP) concerning the role of antibiotics when children suffer from URIs, as well as to evaluate the response rates, the completeness and the reliability (Cronbach) of the questionnaires. Finally, to note any limitations of the study.</p> <p>Methods</p> <p>Literature review, along with pre – testing yielded a questionnaire designed to assess the parents' KAP – level. A postal survey was set, in a national sample of 200 schools stratified by geographical region. The participants consist of a multistage geographical cluster sample of 8000 parents. The influence of demographic characteristics (i.e. sex, age, education) was analyzed. Cronbach index test and factor analysis were used to assess the reliability of the questionnaire.</p> <p>Results</p> <p>The response rate of the parents was 69%. Islands presented the lowest response rate while in Northern Greece the response rate was the highest. Sixty – eight point nine percent of the sample returned questionnaires fully completed, while 91.5% completed 95% of the questions. Three questions out of 70 were answered in a very low rate which was associated mostly with immigrant respondents. The section describing parents' attitude toward antibiotic use was not completed as much as the sections of knowledge or practices. The questions were factor analyzed and 10 out of the 21 extracted factors were finally evaluated, reducing the number of independent variables to 46. The reliability of the questionnaire was 0.55. However, only items that increased the Cronbach when added were eventually included in the final scales raising the internal consistency to 0.68. Limitations of the study, such as the vocabulary and form of the questionnaire and the idiocycrancy of the respondents, emerged during the analysis.</p> <p>Conclusion</p> <p>The response rate and the completeness of the questionnaires were higher than expected, probably attributed to the involvement of the teachers. The study findings were satisfactory regarding the development of a reliable instrument capable to measure parents' KAP characteristics.</p

    Legionella species colonization in cooling towers: Risk factors and assessment of control measures

    No full text
    Background: Cooling towers can be colonized by Legionella spp, and inhalation of aerosols generated by their operation may cause Legionnaires' disease in susceptible hosts. Environmental investigations of Legionnaires' disease outbreaks linked with cooling towers have revealed poorly maintained systems, lack of control measures, and failure of system equipment. The purpose of this study was to identify Legionella-contaminated cooling towers, identify risk factors for contamination, and assess the effectiveness of control measures. Methods: A total of 96 cooling towers of public buildings were registered and inspected, and 130 samples were collected and microbiologically tested. Microbiological test results were associated with characteristics of cooling towers, water samples, inspection results, and maintenance practices. Results: Of the total 96 cooling towers examined, 47 (48.9%) were colonized by Legionella spp, and 22 (22.9%) required remedial action. A total of 65 samples (50.0%) were positive (>= 500 cfu L(-1)), and 30 (23%) were heavily contaminated (>= 10(4) cfu L(-1)). Of the 69 isolates identified, 55 strains (79.7.%) were L pneumophila. Legionella colonization was positively associated with the absence of training on Legionella control ( relative risk [RR] = 1.66; P = .02), absence of regular Legionella testing (RR = 2.07: P = .002), absence of sunlight protection (RR = 1.63: P = .02), with samples in which the free residual chlorine level in the water sample was, = 1000 cfu L(-1). Conclusions: Cooling towers can be heavily colonized by Legionella spp and thus present a potential risk for infection. This study demonstrates the importance of a risk assessment and management plan. Water chlorination effectively reduces legionellae contamination. Proper training of cooling tower operators is paramount

    Evaluation of standardized scored inspections for Legionnaires' disease prevention, during the Athens 2004 Olympics

    No full text
    The study was designed to determine the contribution of standardized scored inspections implemented during the Athens 2004 Pre-Olympic and Olympic period, in assessing the presence of Legionella spp. in water sites. Inspection grading scores of 477 water supply systems, 127 cooling towers and 134 decorative fountains were associated with the corresponding microbiological test results of 2514 samples for Legionella spp. Nine violations of water supply systems and nine of cooling towers significantly associated with positive microbiological test results, and four violations of water supply systems and one of cooling towers were among those designated as ‘critical’ water safety hazards in the inspection reports. The study documents a strong correlation [water supply systems (RR 1·92), cooling towers (RR 1·94)] between unsatisfactory inspection scoring results and Legionella-positive microbiological test results (in excess of 10 000 c.f.u./l) and suggests the utility of inspection scoring systems in predicting Legionella proliferation of water systems and in preventing Legionnaires' disease
    corecore