18 research outputs found
Syncope Time Frames for Adverse Events after Emergency Department Presentation: An Individual Patient Data Meta-Analysis
Eventos adversos; Arritmia; ResultadosAdverse events; Arrhythmia; OutcomesEsdeveniments adversos; ArĂtmia; ResultatsBackground and Objectives: Knowledge of the incidence and time frames of the adverse events of patients presenting syncope at the ED is essential for developing effective management strategies. The aim of the present study was to perform a meta-analysis of the incidence and time frames of adverse events of syncope patients. Materials and Methods: We combined individual patientsâ data from prospective observational studies including adult patients who presented syncope at the ED. We assessed the pooled rate of adverse events at 24 h, 72 h, 7â10 days, 1 month and 1 year after ED evaluation. Results: We included nine studies that enrolled 12,269 patients. The mean age varied between 53 and 73 years, with 42% to 57% females. The pooled rate of adverse events was 5.1% (95% CI 3.4% to 7.7%) at 24 h, 7.0% (95% CI 4.9% to 9.9%) at 72 h, 8.4% (95% CI 6.2% to 11.3%) at 7â10 days, 10.3% (95% CI 7.8% to 13.3%) at 1 month and 21.3% (95% CI 15.8% to 28.0%) at 1 year. The pooled death rate was 0.2% (95% CI 0.1% to 0.5%) at 24 h, 0.3% (95% CI 0.1% to 0.7%) at 72 h, 0.5% (95% CI 0.3% to 0.9%) at 7â10 days, 1% (95% CI 0.6% to 1.7%) at 1 month and 5.9% (95% CI 4.5% to 7.7%) at 1 year. The most common adverse event was arrhythmia, for which its rate was 3.1% (95% CI 2.0% to 4.9%) at 24 h, 4.8% (95% CI 3.5% to 6.7%) at 72 h, 5.8% (95% CI 4.2% to 7.9%) at 7â10 days, 6.9% (95% CI 5.3% to 9.1%) at 1 month and 9.9% (95% CI 5.5% to 17) at 1 year. Ventricular arrhythmia was rare. Conclusions: The risk of death or life-threatening adverse event is rare in patients presenting syncope at the ED. The most common adverse events are brady and supraventricular arrhythmias, which occur during the first 3 days. Prolonged ECG monitoring in the ED in a short stay unit with ECG monitoring facilities may, therefore, be beneficial.This research received no external funding
Syncope Time Frames for Adverse Events after Emergency Department Presentation: An Individual Patient Data Meta-Analysis
Background and Objectives: Knowledge of the incidence and time frames of the adverse events of patients presenting syncope at the ED is essential for developing effective management strategies. The aim of the present study was to perform a meta-analysis of the incidence and time frames of adverse events of syncope patients. Materials and Methods: We combined individual patientsâ data from prospective observational studies including adult patients who presented syncope at the ED. We assessed the pooled rate of adverse events at 24 h, 72 h, 7â10 days, 1 month and 1 year after ED evaluation. Results: We included nine studies that enrolled 12,269 patients. The mean age varied between 53 and 73 years, with 42% to 57% females. The pooled rate of adverse events was 5.1% (95% CI 3.4% to 7.7%) at 24 h, 7.0% (95% CI 4.9% to 9.9%) at 72 h, 8.4% (95% CI 6.2% to 11.3%) at 7â10 days, 10.3% (95% CI 7.8% to 13.3%) at 1 month and 21.3% (95% CI 15.8% to 28.0%) at 1 year. The pooled death rate was 0.2% (95% CI 0.1% to 0.5%) at 24 h, 0.3% (95% CI 0.1% to 0.7%) at 72 h, 0.5% (95% CI 0.3% to 0.9%) at 7â10 days, 1% (95% CI 0.6% to 1.7%) at 1 month and 5.9% (95% CI 4.5% to 7.7%) at 1 year. The most common adverse event was arrhythmia, for which its rate was 3.1% (95% CI 2.0% to 4.9%) at 24 h, 4.8% (95% CI 3.5% to 6.7%) at 72 h, 5.8% (95% CI 4.2% to 7.9%) at 7â10 days, 6.9% (95% CI 5.3% to 9.1%) at 1 month and 9.9% (95% CI 5.5% to 17) at 1 year. Ventricular arrhythmia was rare. Conclusions: The risk of death or life-threatening adverse event is rare in patients presenting syncope at the ED. The most common adverse events are brady and supraventricular arrhythmias, which occur during the first 3 days. Prolonged ECG monitoring in the ED in a short stay unit with ECG monitoring facilities may, therefore, be beneficial
Cardiac autonomic control in Rett syndrome: Insights from heart rate variability analysis
Rett syndrome (RTT) is a rare and severe neurological disorder mainly affecting females, usually linked to methyl-CpG-binding protein 2 (MECP2) gene mutations. Manifestations of RTT typically include loss of purposeful hand skills, gait and motor abnormalities, loss of spoken language, stereotypic hand movements, epilepsy, and autonomic dysfunction. Patients with RTT have a higher incidence of sudden death than the general population. Literature data indicate an uncoupling between measures of breathing and heart rate control that could offer insight into the mechanisms that lead to greater vulnerability to sudden death. Understanding the neural mechanisms of autonomic dysfunction and its correlation with sudden death is essential for patient care. Experimental evidence for increased sympathetic or reduced vagal modulation to the heart has spurred efforts to develop quantitative markers of cardiac autonomic profile. Heart rate variability (HRV) has emerged as a valuable non-invasive test to estimate the modulation of sympathetic and parasympathetic branches of the autonomic nervous system (ANS) to the heart. This review aims to provide an overview of the current knowledge on autonomic dysfunction and, in particular, to assess whether HRV parameters can help unravel patterns of cardiac autonomic dysregulation in patients with RTT. Literature data show reduced global HRV (total spectral power and R-R mean) and a shifted sympatho-vagal balance toward sympathetic predominance and vagal withdrawal in patients with RTT compared to controls. In addition, correlations between HRV and genotype and phenotype features or neurochemical changes were investigated. The data reported in this review suggest an important impairment in sympatho-vagal balance, supporting possible future research scenarios, targeting ANS
The role of immune suppression in COVID-19 hospitalization: clinical and epidemiological trends over three years of SARS-CoV-2 epidemic
Specific immune suppression types have been associated with a greater risk of severe COVID-19 disease and death. We analyzed data from patients >17âyears that were hospitalized for COVID-19 at the âFondazione IRCCS CaâČ Granda Ospedale Maggiore Policlinicoâ in Milan (Lombardy, Northern Italy). The study included 1727 SARS-CoV-2-positive patients (1,131 males, median age of 65âyears) hospitalized between February 2020 and November 2022. Of these, 321 (18.6%, CI: 16.8â20.4%) had at least one condition defining immune suppression. Immune suppressed subjects were more likely to have other co-morbidities (80.4% vs. 69.8%, pâ<â0.001) and be vaccinated (37% vs. 12.7%, pâ<â0.001). We evaluated the contribution of immune suppression to hospitalization during the various stages of the epidemic and investigated whether immune suppression contributed to severe outcomes and death, also considering the vaccination status of the patients. The proportion of immune suppressed patients among all hospitalizations (initially stable at <20%) started to increase around December 2021, and remained high (30â50%). This change coincided with an increase in the proportions of older patients and patients with co-morbidities and with a decrease in the proportion of patients with severe outcomes. Vaccinated patients showed a lower proportion of severe outcomes; among non-vaccinated patients, severe outcomes were more common in immune suppressed individuals. Immune suppression was a significant predictor of severe outcomes, after adjusting for age, sex, co-morbidities, period of hospitalization, and vaccination status (OR: 1.64; 95% CI: 1.23â2.19), while vaccination was a protective factor (OR: 0.31; 95% IC: 0.20â0.47). However, after November 2021, differences in disease outcomes between vaccinated and non-vaccinated groups (for both immune suppressed and immune competent subjects) disappeared. Since December 2021, the spread of the less virulent Omicron variant and an overall higher level of induced and/or natural immunity likely contributed to the observed shift in hospitalized patient characteristics. Nonetheless, vaccination against SARS-CoV-2, likely in combination with naturally acquired immunity, effectively reduced severe outcomes in both immune competent (73.9% vs. 48.2%, pâ<â0.001) and immune suppressed (66.4% vs. 35.2%, pâ<â0.001) patients, confirming previous observations about the value of the vaccine in preventing serious disease
Syncope Time Frames for Adverse Events after Emergency Department Presentation : An Individual Patient Data Meta-Analysis
Knowledge of the incidence and time frames of the adverse events of patients presenting syncope at the ED is essential for developing effective management strategies. The aim of the present study was to perform a meta-analysis of the incidence and time frames of adverse events of syncope patients. We combined individual patients' data from prospective observational studies including adult patients who presented syncope at the ED. We assessed the pooled rate of adverse events at 24 h, 72 h, 7-10 days, 1 month and 1 year after ED evaluation. We included nine studies that enrolled 12,269 patients. The mean age varied between 53 and 73 years, with 42% to 57% females. The pooled rate of adverse events was 5.1% (95% CI 3.4% to 7.7%) at 24 h, 7.0% (95% CI 4.9% to 9.9%) at 72 h, 8.4% (95% CI 6.2% to 11.3%) at 7-10 days, 10.3% (95% CI 7.8% to 13.3%) at 1 month and 21.3% (95% CI 15.8% to 28.0%) at 1 year. The pooled death rate was 0.2% (95% CI 0.1% to 0.5%) at 24 h, 0.3% (95% CI 0.1% to 0.7%) at 72 h, 0.5% (95% CI 0.3% to 0.9%) at 7-10 days, 1% (95% CI 0.6% to 1.7%) at 1 month and 5.9% (95% CI 4.5% to 7.7%) at 1 year. The most common adverse event was arrhythmia, for which its rate was 3.1% (95% CI 2.0% to 4.9%) at 24 h, 4.8% (95% CI 3.5% to 6.7%) at 72 h, 5.8% (95% CI 4.2% to 7.9%) at 7-10 days, 6.9% (95% CI 5.3% to 9.1%) at 1 month and 9.9% (95% CI 5.5% to 17) at 1 year. Ventricular arrhythmia was rare. The risk of death or life-threatening adverse event is rare in patients presenting syncope at the ED. The most common adverse events are brady and supraventricular arrhythmias, which occur during the first 3 days. Prolonged ECG monitoring in the ED in a short stay unit with ECG monitoring facilities may, therefore, be beneficial
Social Isolation: A Narrative Review on the Dangerous Liaison between the Autonomic Nervous System and Inflammation
Social isolation and feelings of loneliness are related to higher mortality and morbidity. Evidence from studies conducted during space missions, in space analogs, and during the COVID-19 pandemic underline the possible role of the autonomic nervous system in mediating this relation. Indeed, the activation of the sympathetic branch of the autonomic nervous system enhances the cardiovascular response and activates the transcription of pro-inflammatory genes, which leads to a stimulation of inflammatory activation. This response is adaptive in the short term, in that it allows one to cope with a situation perceived as a threat, but in the long term it has detrimental effects on mental and physical health, leading to mood deflection and an increased risk of cardiovascular disease, as well as imbalances in immune system activation. The aim of this narrative review is to present the contributions from space studies and insights from the lockdown period on the relationship between social isolation and autonomic nervous system activation, focusing on cardiovascular impairment and immune imbalance. Knowing the pathophysiological mechanisms underlying this relationship is important as it enables us to structure effective countermeasures for the new challenges that lie ahead: the lengthening of space missions and Mars exploration, the specter of future pandemics, and the aging of the population
Application of muon tomography to detect radioactive sources hidden in scrap metal containers2013 3rd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications (ANIMMA)
none13The accidental melting of radioactive sources hidden inside metal scrap containers can produce severe environmental harm. Modern melting facilities are equipped with portals measuring radiation levels. Nonetheless, sources can pass undiscovered when shielded inside shells of high density material, such as lead. From time to time indeed some radioactive sources pass undetected through the controls at foundries entrance. Once melted they caused enormous damages to the steel mills, contaminating all the production line. The muon tomography technique allows to discriminate high- Z materials measuring multiple scattering of cosmic ray muons inside matter. Therefore this technique can be used to analyze a truck container searching for high-density source shields. We report here the results about simulation studies of a muon tomography portal. Within the Mu-Steel European project we developed the prototype design, the three-dimensional images reconstruction software and the high density material identification algorithm. MonteCarlo simulation was validated with data from a large volume demonstrator (~11 m3) built using spare muon drift-time chambers of the CMS high energy physics experiment operating at the Large Hadron Collider at CERN.noneMatteo Furlan;Andrea Rigoni;Sara Vanini;Gianni Zumerle;Paolo Checchia;Ludovico Cossutta;Giacomo Bettella;Pietro Zanuttigh;Piero Calvini;Luca Dassa;Antonietta Donzella;Germano Bonomi;Aldo ZenoniFurlan, Matteo; RIGONI GAROLA, Andrea; Vanini, Sara; Zumerle, Gianni; Checchia, Paolo; Ludovico, Cossutta; Bettella, Giacomo; Zanuttigh, Pietro; Piero, Calvini; Luca, Dassa; Antonietta, Donzella; Germano, Bonomi; Aldo, Zenon
Application of Muon Tomography to Detect Radioactive Sources Hidden in Scrap Metal Containers
The accidental melting of radioactive sources hidden inside metal scrap containers can produce severe environmental harm. Modern melting facilities are equipped with portals measuring radiation levels. Nonetheless, sources can pass undiscovered when shielded inside shells of high density material, such as lead. From time to time indeed some radioactive sources pass undetected through the controls at foundries entrance. Once molten they caused enormous damages to the steel mills, contaminating all the production line. The muon tomography technique allows to discriminate high-Z materials measuring multiple scattering of cosmic ray muons inside matter. Therefore this technique can be used to analyse a truck container searching for high-density source shields. We report here the results about simulation studies of a muon tomography portal. Within the Mu-Steel European project we developed the prototype design, the three-dimensional images reconstruction software and the high density material identification algorithm. MonteCarlo simulation was validated with data from a large volume demonstrator (~11 m3) built using spare muon drift-time chambers of the CMS high energy physics experiment operating at the Large Hadron Collider at CERN