60 research outputs found

    Detection of nonmagnetic metal thin film using magnetic force microscopy

    Get PDF
    Magnetic force microscopy (MFM) allows detection of stray magnetic fields around magnetic materials and the two-dimensional visualization of these fields. This paper presents a theoretical analysis of the oscillations of an MFM tip above a thin film of nonmagnetic metal. The results show good agreement with experimental data obtained by varying the tip height. The phenomenon analyzed here can be applied as a "metal detector" at the nanometer scale and for contactless measurement of sheet resistivity. The detection sensitivity is obtained as a function of oscillation frequency, thus allowing determination of the best frequency for phase-shift measurement. The shift in resonance frequency due to the presence of a nonmagnetic metal is also discussed.Comment: 4 pages, 5 figure

    Crucial roles of Robo proteins in midline crossing of cerebellofugal axons and lack of their up-regulation after midline crossing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Robo1, Robo2 and Rig-1 (Robo3), members of the Robo protein family, are candidate receptors for the chemorepellents Slit and are known to play a crucial role in commissural axon guidance in the spinal cord. However, their roles at other axial levels remain unknown. Here we examine expression of Robo proteins by cerebellofugal (CF) commissural axons in the rostral hindbrain and investigate their roles in CF axon pathfinding by analysing Robo knockout mice.</p> <p>Results</p> <p>We analysed the expression of Robo proteins by CF axons originating from deep cerebellar neurons in rodent embryos, focusing on developmental stages of their midline crossing and post-crossing navigation. At the stage of CF axon midline crossing, mRNAs of Robo1 and Robo2 are expressed in the nuclear transitory zone of the cerebellum, where the primordium of the deep cerebellar nuclei are located, supporting the notion that CF axons express Robo1 and Robo2. Indeed, immunohistochemical analysis of CF axons labelled by electroporation to deep cerebellar nuclei neurons indicates that Robo1 protein, and possibly also Robo2 protein, is expressed by CF axons crossing the midline. However, weak or no expression of these proteins is found on the longitudinal portion of CF axons. In <it>Robo1</it>/<it>2 </it>double knockout mice, many CF axons reach the midline but fail to exit it. We find that CF axons express Rig-1 (Robo3) before they reach the midline but not after the longitudinal turn. Consistent with this <it>in vivo </it>observation, axons elicited from a cerebellar explant in co-culture with a floor plate explant express Rig-1. In <it>Rig-1 </it>deficient mouse embryos, CF axons appear to project ipsilaterally without reaching the midline.</p> <p>Conclusion</p> <p>These results indicate that Robo1, Robo2 or both are required for midline exit of CF axons. In contrast, Rig-1 is required for their approach to the midline. However, post-crossing up-regulation of these proteins, which plays an important role in spinal commissural axon guidance, does not appear to be required for the longitudinal navigation of CF axons after midline crossing. Our results illustrate that although common mechanisms operate for midline crossing at different axial levels, significant variation exists in post-crossing navigation.</p

    Netrin-1 Derived from the Ventricular Zone, but not the Floor Plate, Directs Hindbrain Commissural Axons to the Ventral Midline

    No full text
    Abstract Netrin-1 (Ntn1) emanating from the ventral midline has been thought to act as a long-range diffusible chemoattractant for commissural axons (CAs). However, CAs still grow towards the midline in the absence of the floor plate (FP), a glial structure occupying the midline. Here, using genetically loss-of-function approaches in mice, we show that Ntn1 derived from the ventricular zone (VZ), but not the FP, is crucial for CA guidance in the mouse hindbrain. During the period of CA growth, Ntn1 is expressed in the ventral two-thirds of the VZ, in addition to the FP. Remarkably, deletion of Ntn1 from the VZ and even from the dorsal VZ highly disrupts CA guidance to the midline, whereas the deletion from the FP has little impact on it. We also show that the severities of CA guidance defects found in the Ntn1 conditional mutants were irrelevant to their FP long-range chemoattractive activities. Our results are incompatible with the prevailing view that Ntn1 is an FP-derived long-range diffusible chemoattractant for CAs, but suggest a novel mechanism that VZ-derived Ntn1 directs CAs to the ventral midline by its local actions

    Comparison of corneal thickness in patients with dry eye disease using the Pentacam rotating Scheimpflug camera and anterior segment optical coherence tomography.

    No full text
    The purpose of this study was to compare central corneal thickness, thinnest corneal thickness, and the thinnest point of the cornea between Pentacam and anterior segment optical coherence tomography (ASOCT) in patients with dry eye disease (DED). This cross-sectional study included 195 participants between November 2015-June 2017. DED was diagnosed using the Asia Dry Eye Society criteria and further divided into mild and severe DED based on kerato-conjunctival vital staining. Central corneal thickness, thinnest corneal thickness, and the thinnest point of the cornea measured by Pentacam and ASOCT were compared, and Pearson's correlation coefficients were estimated. The differences in central corneal thickness and the thinnest corneal thickness between Pentacam and ASOCT were analysed using Bland-Altman and multivariate regression analyses adjusted for age and sex. This study included 70 non-DED subjects and 52 patients with mild and 73 with severe DED. The Pentacam and ASOCT measurements of central corneal thickness and thinnest corneal thickness were strongly correlated, but the respective values were higher when measured with Pentacam. The Bland-Altman analysis revealed differences in central corneal thickness (non DED, 11.8; mild DED, 13.2; severe DED, 19.6) and in thinnest corneal thickness (non DED, 13.1; mild DED, 13.4; severe DED, 20.7). After adjusting for age and sex, the differences in central corneal thickness (β = 7.029 μm, 95%CI 2.528-11.530) and thinnest corneal thickness (β = 6.958 μm, 95%CI 0.037-13.879) were significantly increased in the severe-DED group. The distribution of the thinnest point of the cornea in the cornea's inferior temporal quadrant between Pentacam and ASOCT deviated in severe DED (Pentacam: 90.4% vs. ASOCT: 83.6%). Clinicians should consider that there were significant differences in corneal-morphology assessment between the measurements with Pentacam and ASOCT in severe DED

    A Review of Dry Eye Questionnaires: Measuring Patient-Reported Outcomes and Health-Related Quality of Life.

    No full text
    Dry eye disease (DED) is among the most common eye diseases and is becoming increasingly prevalent. Its symptoms cause a long-term decline in patients\u27 health-related quality of life (HRQL). Inconsistencies often occur between the clinical findings and the subjective symptoms of DED. Therefore, a holistic, balanced, and quantitative evaluation of the subjective symptoms and HRQL using patient-reported outcome questionnaires, in addition to clinical findings, is crucial for accurate DED assessment in patients. This paper reviewed the characteristics of current dry eye questionnaires, including their objectives, number of questions, inclusion of HRQL-related items, and whether they were properly evaluated for psychometric properties. Twenty-four questionnaires were identified; among them, the following six questionnaires that included items assessing HRQL and were properly evaluated for psychometric properties are recommended: the Ocular Surface Disease Index, Impact of Dry Eye in Everyday Life, Dry Eye-Related Quality-of-life Score, University of North Carolina Dry Eye Management Scale, Chinese version of Dry Eye-Related Quality of Life, and 25-Item National Eye Institute Visual Function Questionnaire. Dry eye questionnaires have different objectives and are available in different languages. Therefore, medical practitioners should confirm the characteristics of applicable questionnaires before selecting the most appropriate ones

    A Review of Dry Eye Questionnaires: Measuring Patient-Reported Outcomes and Health-Related Quality of Life

    No full text
    Dry eye disease (DED) is among the most common eye diseases and is becoming increasingly prevalent. Its symptoms cause a long-term decline in patients&rsquo; health-related quality of life (HRQL). Inconsistencies often occur between the clinical findings and the subjective symptoms of DED. Therefore, a holistic, balanced, and quantitative evaluation of the subjective symptoms and HRQL using patient-reported outcome questionnaires, in addition to clinical findings, is crucial for accurate DED assessment in patients. This paper reviewed the characteristics of current dry eye questionnaires, including their objectives, number of questions, inclusion of HRQL-related items, and whether they were properly evaluated for psychometric properties. Twenty-four questionnaires were identified; among them, the following six questionnaires that included items assessing HRQL and were properly evaluated for psychometric properties are recommended: the Ocular Surface Disease Index, Impact of Dry Eye in Everyday Life, Dry Eye-Related Quality-of-life Score, University of North Carolina Dry Eye Management Scale, Chinese version of Dry Eye-Related Quality of Life, and 25-Item National Eye Institute Visual Function Questionnaire. Dry eye questionnaires have different objectives and are available in different languages. Therefore, medical practitioners should confirm the characteristics of applicable questionnaires before selecting the most appropriate ones
    • …
    corecore