8 research outputs found

    The optical system of the Tenerife Microwave Spectrometer: a window for observing the 10-20 GHz sky spectra

    Full text link
    The TMS optical system is based on a decentered dual-reflector system in a Gregorian configuration to observe with an angular resolution of less than 22^\circ. The primary goal of the present study is to evaluate the final design and verify that it satisfies the design requirements. We aim for low cross-polarization (-30 dB), low sidelobe (-25 dB) levels, and a stable beam in terms of shape (low ellipticity) and size over a full octave bandwidth (10-20 GHz). We performed both ray-tracing and full-wave simulations using the CST Studio software in order to investigate the system behaviour. We gave special attention to the beam frequency variation and polarization leakage. We have characterized the effects on the radiation pattern produced by the cryostat window. We present the final design of the TMS optical system, as well as a complete study of the system's performance in terms of cross-polarization, sidelobes, ellipticity and beamwidth. We discuss the effects of sidelobes and study the need for a baffle.Comment: 30 pages, 15 figures. Accepted for publication in JINS

    Nanostructured Oxides in Chemistry: Characterization and Properties

    No full text

    Outpatient Parenteral Antibiotic Treatment for Infective Endocarditis: A Prospective Cohort Study From the GAMES Cohort

    No full text
    BACKGROUND: Outpatient parenteral antibiotic treatment (OPAT) has proven efficacious for treating infective endocarditis (IE). However, the 2001 Infectious Diseases Society of America (IDSA) criteria for OPAT in IE are very restrictive. We aimed to compare the outcomes of OPAT with those of hospital-based antibiotic treatment (HBAT). METHODS: Retrospective analysis of data from a multicenter, prospective cohort study of 2000 consecutive IE patients in 25 Spanish hospitals (2008-2012) was performed. RESULTS: A total of 429 patients (21.5%) received OPAT, and only 21.7% fulfilled IDSA criteria. Males accounted for 70.5%, median age was 68 years (interquartile range [IQR], 56-76), and 57% had native-valve IE. The most frequent causal microorganisms were viridans group streptococci (18.6%), Staphylococcus aureus (15.6%), and coagulase-negative staphylococci (14.5%). Median length of antibiotic treatment was 42 days (IQR, 32-54), and 44% of patients underwent cardiac surgery. One-year mortality was 8% (42% for HBAT; P < .001), 1.4% of patients relapsed, and 10.9% were readmitted during the first 3 months after discharge (no significant differences compared with HBAT). Charlson score (odds ratio [OR], 1.21; 95% confidence interval [CI], 1.04-1.42; P = .01) and cardiac surgery (OR, 0.24; 95% CI, .09-.63; P = .04) were associated with 1-year mortality, whereas aortic valve involvement (OR, 0.47; 95% CI, .22-.98; P = .007) was the only predictor of 1-year readmission. Failing to fulfill IDSA criteria was not a risk factor for mortality or readmission. CONCLUSIONS: OPAT provided excellent results despite the use of broader criteria than those recommended by IDSA. OPAT criteria should therefore be expanded
    corecore