297 research outputs found
Electro-energetics of Biventricular, Septal and Conduction System Pacing
Abnormal electrical activation of the ventricles creates abnormalities in cardiac mechanics. Local contraction patterns, as reflected by strain, are not only out of phase, but also show opposing length changes in early and late activated regions. Consequently, the efficiency of cardiac pump function (the amount of stroke work generated by a unit of oxygen consumed), is approximately 30% lower in dyssynchronous than in synchronous hearts. Maintaining good cardiac efficiency appears important for long-term outcomes. Biventricular, left ventricular septal, His bundle and left bundle branch pacing may minimise the amount of pacing-induced dyssynchrony and efficiency loss when compared to conventional right ventricular pacing. An extensive animal study indicates maintenance of mechanical synchrony and efficiency during left ventricular septal pacing and data from a few clinical studies support the idea that this is also the case for left bundle branch pacing and His bundle pacing. This review discusses electro-mechanics and mechano-energetics under the various paced conditions and provides suggestions for future research
Novel bradycardia pacing strategies
Contains fulltext :
229186.pdf (Publisher’s version ) (Closed access)The adverse effects of ventricular dyssynchrony induced by right ventricular (RV) pacing has led to alternative pacing strategies, such as biventricular, His bundle (HBP), LV septal (LVSP) and left bundle branch pacing (LBBP). Given the overlap, LVSP and LBBP are also collectively referred to as left bundle branch area pacing (LBBAP). Although among these alternative pacing sites HBP is theoretically the ideal strategy as it maintains a physiological ventricular activation, its application requires more skills and is associated with the most complications. LBBAP, where the ventricular pacing lead is advanced through the interventricular septum to its left side, creates ventricular activation that is only slightly more dyssynchronous. Preliminary studies have shown that LBBAP is feasible, safe and encounters less limitations than HBP. Further studies are needed to differentiate between LVSP and LBBP with regard to acute functional and long-term clinical outcome
Left Ventricular Endocardial Pacing Improves Resynchronization Therapy in Canine Left Bundle-Branch Hearts
Background—
We investigated the benefits of the more physiological activation achieved by left ventricular (LV) endocardial pacing (ENDO) as compared with conventional epicardial (EPI) LV pacing in cardiac resynchronization therapy.
Methods and Results—
In 8 anesthetized dogs with experimental left bundle-branch block, pacing leads were positioned in the right atrium, right ventricle, and at 8 paired (EPI and ENDO) LV sites. Systolic LV pump function was assessed as LVdP/dtmax and stroke work and diastolic function as LVdP/dtmin. Electrical activation and dispersion of repolarization were determined from 122 epicardial and endocardial electrodes and from analysis of the surface ECG. Overall, ENDO-biventricular (BiV) pacing more than doubled the degree of electrical resynchronization and increased the benefit on LVdP/dtmax and stroke work by 90% and 50%, respectively, as compared with EPI-BiV pacing. During single-site LV pacing, the range of AV intervals with a >10% increase in LV resynchronization (79�31 versus 32�24 ms,
P
<0.05) and LVdP/dtmax (92�29 versus 63�39 ms) was significantly longer for ENDO than for EPI pacing. EPI-BiV but not ENDO-BiV pacing created a significant (40�21 ms) transmural dispersion of repolarization.
Conclusions—
Data from this acute animal study indicate that the use of an endocardial LV pacing electrode may increase the efficacy of resynchronization therapy as compared with conventional epicardial resynchronization therapy
Evaluation of the Performance of Coordinate Measuring Machines in the Industry, Using Calibrated Artefacts
AbstractThe coordinate measuring machines (CMM's) has given a new impulse in the field of geometrical and dimensional metrology. The CMM's in industrial environments have become an important resource for the quality systems, monitoring manufacturing processes, reduction errors during the manufacturing process, inspection of product specifications and in continuous quality improvement. However, there is a need to evaluate, through practical, fast, effective and low cost methods, the CMM metrological specifications. Using calibrated artefacts, able to reproduce the geometric elements frequently measured, it seeks to ensure stability of the functional and metrological characteristics between calibrations and simultaneously knowing the errors. With better monitoring of the control parameters it is possible evaluate and optimize the calibration set deadlines, timely detection of faults and failures, detect structural changes and changes in environmental conditions of the laboratories, thus seeking to conduct a more detailed assessment of the stability of metrological characteristics of a CMM in industrial environments
Reduction in the QRS area after cardiac resynchronization therapy is associated with survival and echocardiographic response
Introduction Recent studies have shown that the baseline QRS area is associated with the clinical response after cardiac resynchronization therapy (CRT). In this study, we investigated the association of QRS area reduction ( increment QRS area) after CRT with the outcome. We hypothesize that a larger increment QRS area is associated with a better survival and echocardiographic response. Methods and Results Electrocardiograms (ECG) obtained before and 2-12 months after CRT from 1299 patients in a multi-center CRT-registry were analyzed. The QRS area was calculated from vectorcardiograms that were synthesized from 12-lead ECGs. The primary endpoint was a combination of all-cause mortality, heart transplantation, and left ventricular (LV) assist device implantation. The secondary endpoint was the echocardiographic response, defined as LV end-systolic volume reduction >= of 15%. Patients with increment QRS area above the optimal cut-off value (62 mu Vs) had a lower risk of reaching the primary endpoint (hazard ratio: 0.43; confidence interval [CI] 0.33-0.56, p = 109 mu Vs, survival, and echocardiographic response were better when the increment QRS area was >= 62 mu Vs (p = 109 mu Vs, increment QRS area was the only significant predictor of survival (OR: 0.981; CI: 0.967-0.994, p = .006). Conclusion increment QRS area is an independent determinant of CRT response, especially in patients with a large baseline QRS area. Failure to achieve a large QRS area reduction with CRT is associated with a poor clinical outcome
Heart Size Corrected Electrical Dyssynchrony and Its Impact on Sex-specific Response to Cardiac Resynchronization Therapy
Background - Women are less likely to receive cardiac resynchronization therapy (CRT), yet, they are more responsive to the therapy and respond at shorter QRS duration. The present study hypothesized that a relatively larger left ventricular (LV) electrical dyssynchrony in smaller hearts contributes to the better CRT response in women. For this the vectorcardiography-derived QRS area is used, since it allows for a more detailed quantification of electrical dyssynchrony compared to conventional electrocardiographic markers. Methods - Data from a multicenter registry of 725 CRT patients (median follow-up: 4.2 years [IQR: 2.7-6.1]) were analyzed. Baseline electrical dyssynchrony was evaluated using the QRS area, and the corrected QRS area for heart size using the LV end-diastolic volume (QRSarea/LVEDV). Impact of the QRSarea/LVEDV-ratio on the association between sex and LV reverse remodeling (end-systolic volume change: ΔLVESV) and sex and the composite outcome of all-cause mortality, LV assist device implantation or heart transplantation was assessed. Results - At baseline, women (n=228) displayed larger electrical dyssynchrony than men (QRS area: 132±55μVs vs 123±58μVs, p=0.043) which was, even more pronounced for the QRSarea/LVEDV-ratio (0.76±0.46μVs/ml vs 0.57±0.34μVs/ml, p<0.001). After multivariable analyses female sex was associated with ΔLVESV (β 0.12, p=0.003) and a lower occurrence the composite outcome (HR 0.59 (0.42-0.85), p=0.004). A part of the female advantage regarding reverse remodeling was attributed to the larger QRSarea/LVEDV-ratio in women (25-fold change in Beta from 0.12 to 0.09). The larger QRSarea/LVEDV-ratio did not contribute to the better survival observed in women. In both volumetric responders and non-responders, female sex remained strongly associated with a lower risk of the composite outcome (adjusted HR 0.59 (0.36-0.97), p=0.036 and 0.55 (0.33-0.90), p=0.018, respectively). Conclusions - Greater electrical dyssynchrony in smaller hearts contributes in part to more reverse remodeling observed in women after CRT, but this does not explain their better long-term outcomes
- …