213 research outputs found

    Passive mechanical features of single fibers from human muscle biopsies – effects of storage

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of this study was to investigate the effect of storage of human muscle biopsies on passive mechanical properties.</p> <p>Methods</p> <p>Stress-strain analysis accompanied by laser diffraction assisted sarcomere length measurement was performed on single muscle fibres from fresh samples and compared with single fibres from stored samples (-20°C, 4 weeks) with the same origin as the corresponding fresh sample. Basic morphological analysis, including cross sectional area (CSA) measurement, fibre diameter measurement, fibre occupancy calculation and overall morphology evaluation was done.</p> <p>Results</p> <p>Statistical analysis of tangent values in stress-strain curves, corresponding to the elastic modulus of single muscle fibres, did not differ when comparing fresh and stored samples from the same type of muscle. Regardless of the preparation procedure, no significant differences were found, neither in fibre diameter nor the relation between muscle fibres and extra-cellular matrix measured under light microscopy.</p> <p>Conclusion</p> <p>We conclude that muscle fibre structure and mechanics are relatively insensitive to the storage procedures used and that the different preparations are interchangeable without affecting passive mechanical properties. This provides a mobility of the method when harvesting muscle biopsies away from the laboratory.</p

    On the behavior of micro-spheres in a hydrogen pellet target

    Full text link
    A pellet target produces micro-spheres of different materials, which are used as an internal target for nuclear and particle physics studies. We will describe the pellet hydrogen behavior by means of fluid dynamics and thermodynamics. In particular one aim is to theoretically understand the cooling effect in order to find an effective method to optimize the working conditions of a pellet target. During the droplet formation the evaporative cooling is best described by a multi-droplet diffusion-controlled model, while in vacuum, the evaporation follows the (revised) Hertz-Knudsen formula. Experimental observations compared with calculations clearly indicated the presence of supercooling, the effect of which is discussed as well.Comment: 22 pages, 8 figures (of which two are significantly compressed for easier download

    Balance in single-limb stance in healthy subjects – reliability of testing procedure and the effect of short-duration sub-maximal cycling

    Get PDF
    BACKGROUND: To assess balance in single-limb stance, center of pressure movements can be registered by stabilometry with force platforms. This can be used for evaluation of injuries to the lower extremities. It is important to ensure that the assessment tools we use in the clinical setting and in research have minimal measurement error. Previous studies have shown that the ability to maintain standing balance is decreased by fatiguing exercise. There is, however, a need for further studies regarding possible effects of general exercise on balance in single-limb stance. The aims of this study were: 1) to assess the test-retest reliability of balance variables measured in single-limb stance on a force platform, and 2) to study the effect of exercise on balance in single-limb stance, in healthy subjects. METHODS: Forty-two individuals were examined for test-retest reliability, and 24 individuals were tested before (pre-exercise) and after (post-exercise) short-duration, sub-maximal cycling. Amplitude and average speed of center of pressure movements were registered in the frontal and sagittal planes. Mean difference between test and retest with 95% confidence interval, the intraclass correlation coefficient, and the Bland and Altman graphs with limits of agreement, were used as statistical methods for assessing test-retest reliability. The paired t-test was used for comparisons between pre- and post-exercise measurements. RESULTS: No difference was found between test and retest. The intraclass correlation coefficients ranged from 0.79 to 0.95 in all stabilometric variables except one. The limits of agreement revealed that small changes in an individual's performance cannot be detected. Higher values were found after cycling in three of the eight stabilometric variables. CONCLUSIONS: The absence of systematic variation and the high ICC values, indicate that the test is reliable for distinguishing among groups of subjects. However, relatively large differences in an individual's balance performance would be required to confidently state that a change is real. The higher values found after cycling, indicate compensatory mechanisms intended to maintain balance, or a decreased ability to maintain balance. It is recommended that average speed and DEV 10; the variables showing the best reliability and effects of exercise, be used in future studies

    Measurements of knee rotation-reliability of an external device in vivo

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device.</p> <p>Method</p> <p>The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient <sub>2,1 </sub>(ICC <sub>2,1</sub>), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests.</p> <p>Result</p> <p>ICC<sub>2,1 </sub>ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque.</p> <p>Conclusion</p> <p>The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque.</p

    On The Rate and Extent of Drug Delivery to the Brain

    Get PDF
    To define and differentiate relevant aspects of blood–brain barrier transport and distribution in order to aid research methodology in brain drug delivery. Pharmacokinetic parameters relative to the rate and extent of brain drug delivery are described and illustrated with relevant data, with special emphasis on the unbound, pharmacologically active drug molecule. Drug delivery to the brain can be comprehensively described using three parameters: Kp,uu (concentration ratio of unbound drug in brain to blood), CLin (permeability clearance into the brain), and Vu,brain (intra-brain distribution). The permeability of the blood–brain barrier is less relevant to drug action within the CNS than the extent of drug delivery, as most drugs are administered on a continuous (repeated) basis. Kp,uu can differ between CNS-active drugs by a factor of up to 150-fold. This range is much smaller than that for log BB ratios (Kp), which can differ by up to at least 2,000-fold, or for BBB permeabilities, which span an even larger range (up to at least 20,000-fold difference). Methods that measure the three parameters Kp,uu, CLin, and Vu,brain can give clinically valuable estimates of brain drug delivery in early drug discovery programmes
    • 

    corecore