17 research outputs found

    Preliminary Evidence of Efficacy, Safety, and Treatment Satisfaction with Tirbanibulin 1% Ointment: A Clinical Perspective on Actinic Keratoses

    Get PDF
    background: actinic keratosis is a common precancerous skin lesion that can progress into invasive squamous cell carcinomas. many topical treatments for actinic keratoses often have poor tolerability and prolonged duration. Tirbanibulin is a novel synthetic drug with potent antitumor and antiproliferative activities. methods: we conducted a single-center, prospective and observational study using tirbanibulin ointment on a 25 cm2 area for 5 consecutive days on 30 participants with AKs on the face or scalp. They were followed for at least 57 days to assess the safety profile and efficacy of the drug as well as treatment satisfaction. we evaluated six signs of local skin reaction (LSR): erythema, scaling, crusting, swelling, blisters/pustules, and erosions/ulcerations, grading the severity as mild, moderate, or severe. The effectiveness was evaluated both clinically and dermoscopically. the treatment satisfaction was assessed using the treatment satisfaction questionnaire for medication (TSQM 1.4). results: on day 57, 70% of the patients showed a complete clinical and dermoscopic response. The highest scores obtained from the TSQM 1.4 were more evident in the convenience and side effects domains. most LSRs, including erythema (83.3%), scaling (30%), and swelling (3.3%), occurred on day 8 but resolved spontaneously. Conclusion: Tirbanibulin is a viable therapeutic option with a short regimen treatment and good tolerability, which favors therapy adherence

    Determination of Traditional and Designer Benzodiazepines in Urine through LC-MS/MS

    No full text
    Background: The detection of new designer benzodiazepines in biological fluids and tissues, together with the traditional ones, could represent an important analytical update for laboratories performing clinical and forensic toxicological analysis. Objective: A liquid chromatography tandem mass spectrometry method (LC-MS/MS) has been developed, fully validated, and applied to a cohort of real urine samples collected from patients under withdrawal treatment and from intoxication cases. Methods: 100 mu L urines were added to a buffer solution containing deuterated internal standards; the samples were then extracted through a liquid/liquid procedure, dried under a nitrogen stream, and reconstituted in mobile phase. The chromatographic separation was performed in reverse phase through a C18 column with gradient elution. Mass spectrometry operated in positive polarization and multiple reaction monitoring mode. Results: 25 molecules were optimized for instrumental analysis: 9 designer benzodiazepines and 16 traditional compounds (parent drugs and main metabolites). Sensitivity, specificity, linearity, accuracy, imprecision, recovery, matrix effects, and carry-over have been evaluated for all molecules. Only cinazepam did not satisfy all acceptance criteria for validation. 10 among the 50 analyzed samples tested positive for at least one of the monitored molecules. In particular, two different samples collected from the same case provided positive results for flubromazepam, a designer benzodiazepine. Conclusion: The method was proven to be useful in detecting not only traditional benzodiazepines but also new designer ones. The identification of a New Psychoactive Substance in real samples confirmed that analytical procedures should be updated to include as many substances as possible

    New Synthetic Cathinones and Phenylethylamine Derivatives Analysis in Hair: A Review

    No full text
    The analysis of psychoactive substances in hair is of great importance for both clinical and forensic toxicologists since it allows one to evaluate past and continuative exposure to xenobiotics. In particular, a new challenge is represented by new psychoactive substances: Among this new class of drugs of abuse, synthetic cathinone and phenethylamine derivatives are often detected in biological samples. Hence, there is a growing need to develop new analytical procedures or improve old ones in order to conduct evaluations of these emerging substances. This study is a systematic review of all the instrumental and experimental data available in the literature. A total of 32 articles were included in the review. Acidic solvents proved to be the most reliable solutions for extraction. Gas chromatography and liquid chromatography coupled to tandem mass spectrometric and high-resolution mass spectrometric systems represent the majority of the involved instrumental techniques. Sensitivity must be maintained at the pg/mg level to detect any occurrences up to occasional consumption. In total, 23 out of 32 articles reported real positive samples. The most frequently detected substance in hair was mephedrone, followed by butylone, methylone, MDPV, and α-pyrrolidinophenone-type substances

    Comparison of Two Immunoassay Screening Methods and a LC-MS/MS in Detecting Traditional and Designer Benzodiazepines in Urine

    No full text
    Sensitive and specific immunoassay screening methods for the detection of benzodiazepines in urine represent an important prerequisite for routine analysis in clinical and forensic toxicology. Moreover, emerging designer benzodiazepines force labs to keep their methodologies updated, in order to evaluate the reliability of the immunochemical techniques. This study aimed at evaluating the sensitivity and specificity of two different immunoassay methods for the detection of benzodiazepines in urine, through a comparison with the results obtained by a newly developed liquid chromatographic tandem mass spectrometric (LC-MS/MS) procedure. A cohort of authentic urine samples (N = 501) were processed, before and after a hydrolysis procedure, through two immunoassays and an LC-MS/MS method. The LC-MS/MS target procedure was optimized for monitoring 25 different molecules, among traditional and designer benzodiazepines, including some metabolites. At least one of the monitored substances was detected in 100 out of the 501 samples. A good specificity was observed for the two immunoassays (>0.99), independently of the cut-offs and the sample hydrolysis. The new kit demonstrated a fairly higher sensitivity, always higher than 0.90; in particular, a high cross-reactivity of the new immunoassay was observed for samples that tested positive for lorazepam and 7-aminoclonazepam. The two immunoassays appeared adequate to monitor not only traditional benzodiazepines but also new designer ones

    Thermal Stability of Ionic Liquids: Effect of Metals

    No full text
    We investigated the thermal stability and corrosion effects of a promising ionic liquid (IL) to be employed as an advanced heat transfer fluid in solar thermal energy applications. Degradation tests were performed on IL samples kept in contact with various metals (steel, copper and brass) at 200 °C for different time lengths. Structural characterization of fresh and aged IL samples was carried out by high-resolution magic angle spinning nuclear magnetic resonance and Fourier transform infrared spectroscopic analyses, while headspace gas chromatography–mass spectrometry was employed to evaluate the release of volatile organic compounds. The combination of the above-mentioned techniques effectively allowed the occurrence of degradation processes due to aging to be verified

    Distribution of Fluvoxamine and Identification of the Main Metabolite in a Fatal Intoxication

    No full text
    Fluvoxamine is a selective serotonin reuptake inhibitor, with a half-life of about 30hours, that is commonly prescribed in the treatment of depression and obsessive and compulsive disorders. Though its more favorable adverse effect profile in comparison to tricyclic antidepressants, overdosages could lead to severe central nervous system depression. We hereby report the case of a 48-year-old woman with psychiatric disorders, who died in the Protected Community where she lived. An autopsy, during which multiorgan congestion and aspiration of gastric content were found, was performed 9days after the death. Femoral and cardiac blood, urine and bile were collected for toxicological analysis. GC-MS, LC-MS-MS and LC-HRMS screenings were performed on blood samples. The analysis allowed to identify the following drugs: fluvoxamine, clotiapine, 7-aminoclonazepam, propranolol, gabapentin and haloperidol. Quantification of the detected drugs in blood was performed by means of a validated LC-MS-MS analytical procedure and the following results were achieved: fluvoxamine (2.20mg/L), gabapentin (41.00mg/L), 7-aminoclonazepam (0.24mg/L), clotiapine (0.07mg/L), haloperidol (<0.01mg/L) and propranolol (0.24mg/L). Fluvoxamine concentration in blood exceeded approximately 10 times the upper limit of therapeutic blood levels (0.23mg/L). Contributory causes of death, due to multiple drugs use, however, cannot be excluded. The distribution of fluvoxamine in all biological fluids was evaluated and a postmortem redistribution effect was observed (C/P blood ratio: 1.86). Fluvoxamine acid metabolite was identified in urine, bile and in cardiac blood, through a LC-QTOF analytical procedure

    Evaluation of benzodiazepines and zolpidem in nails and their stability after prolonged exposure to chlorinated water.

    No full text
    The study aims the development and validation of a LC-MS/MS method for the identification and quantification of benzodiazepines and zolpidem in nails as alternative keratinized matrix to hair in long-term monitoring of anxiolytic and hypnotic drugs. Both fingernail and toenail samples (1-2 mm) were collected by clipping the excess overhang of the nail from volunteers and from postmortem cases. They were washed twice with organic solvents, dried under nitrogen stream, pulverized, immersed in a methanol solution (internal standard: diazepam-D5) and sonicated up to two hours. The solution was then direct injected in the LC-MS/MS system. Mass spectrometry was set in MRM mode, selecting two transitions for each substance. 32 analytes among benzodiazepines, metabolites and hypnotics were included in the list. The method fulfilled the internationally required criteria for validation. Limits of detection ranged from 0.03 pg/mg (zolpidem) to 13.1 pg/mg (bromazepam). 9 subjects under therapy were positive at 7 different benzodiazepines and/or metabolites (lorazepam, desalkylflurazepam, bromazepam, diazepam, alprazolam, lormetazepam and prazepam), while 5 molecules were measured in 4 postmortem cases (diazepam, desmethyldiazepam, delorazepam, 7-aminoclonazepam and zolpidem). In vitro experiments on eight authentic samples suggested that benzodiazepines in nails are influenced by the prolonged exposure to chlorinated water
    corecore