10 research outputs found
Разработка источника питания сварочной дуги на базе импульсно – регулируемого сопротивления
Объектом исследования является процесс импульсно – дуговой сварки плавящейся электродной проволокой.
Цель работы – разработка системы импульсного питания для сварки плавящейся проволокой, формирующая сложный прямоугольный импульс, совмещающий плавление и перенос электродного металла.Object of research is the process of pulse-arc welding with consumable electrode wire.
Purpose of research – the development of pulsed supply system for welding with consumable wire, forming a complex rectangular pulse, which combines melting and electrode metal transferring.
In the process of research the analysis of the known systems for pulse-arc welding with consumable electrode and the analysis of existing practical technical means for pulse shaping were held, the theoretical studies of the effect of pulse forms on the melting process and electrode metal transferring were carried out
A Standardized Collagen-Based Scaffold Improves Human Hepatocyte Shipment and Allows Metabolic Studies over 10 Days
Due to pronounced species differences, hepatotoxicity of new drugs often cannot be detected in animal studies. Alternatively, human hepatocytes could be used, but there are some limitations. The cells are not always available on demand or in sufficient amounts, so far there has been only limited success to allow the transport of freshly isolated hepatocytes without massive loss of function or their cultivation for a long time. Since it is well accepted that the cultivation of hepatocytes in 3D is related to an improved function, we here tested the Optimaix-3D Scaffold from Matricel for the transport and cultivation of hepatocytes. After characterization of the scaffold, we shipped cells on the scaffold and/or cultivated them over 10 days. With the evaluation of hepatocyte functions such as urea production, albumin synthesis, and CYP activity, we showed that the metabolic activity of the cells on the scaffold remained nearly constant over the culture time whereas a significant decrease in metabolic activity occurred in 2D cultures. In addition, we demonstrated that significantly fewer cells were lost during transport. In summary, the collagen-based scaffold allows the transport and cultivation of hepatocytes without loss of function over 10 days
In vitro cell alignment obtained with a Schwann cell enriched microstructured nerve guide with longitudinal guidance channels.
Therapeutic benefits of autologous nerve grafting in repair of peripheral nerve lesions have not been reached using any alternative nerve guide. Nevertheless, issues of co-morbidity and limited availability of donor nerves urgently ask for a need of bioartificial nerve guides which could either replace or complement autologous nerve grafts. It is increasingly appreciated that optimal nerve guides comprise both physical and molecular cues in support of peripheral axon regeneration. Now, we present a collagen-based microstructured 3D nerve guide containing numerous longitudinal guidance channels with dimensions resembling natural endoneurial tubes. Moreover, these nerve guides could be functionalized by Schwann cell (SC) seeding. Viable SCs did not only adhere to the nerve guide, but also migrated throughout the guidance channels. Of particular importance was the observation that SCs within the guidance channels formed cellular columns reminiscent of "Bands of Büngner", which are crucial structures in the natural process of peripheral nerve regeneration during the Wallerian degeneration. We, therefore, conclude that our orientated 3D nerve guides (decorated with SCs) with their physical and molecular properties may hold great promise in the repair of peripheral nerve lesion and serve as a basis for future experimental regeneration studies
Functional improvement following implantation of a microstructured, type-I collagen scaffold into experimental injuries of the adult rat spinal cord
The formation of cystic cavitation following severe spinal cord injury (SCI) constitutes one of the major barriers to successful axonal regeneration and tissue repair. The development of bioengineered scaffolds that assist in the bridging of such lesion-induced gaps may contribute to the formulation of combination strategies aimed at promoting functional tissue repair. Our previous in vitro investigations have demonstrated the directed axon regeneration and glial migration supporting properties of microstructured collagen scaffold that had been engineered to possess mechanical properties similar to those of spinal cord tissues. Here, the effect of implanting the longitudinally orientated scaffold into unilateral resection injuries (2 mm long) of the mid-cervical lateral funiculus of adult rats has been investigated using behavioural and correlative morphological techniques. The resection injuries caused an immediate and long lasting (up to 12 weeks post injury) deficit of food pellet retrieval by the ipsilateral forepaw. Implantation of the orientated collagen scaffold promoted a significant improvement in pellet retrieval by the ipsilateral forepaw at 6 weeks which continued to improve up to 12 weeks post injury. In contrast, implantation of a non-orientated gelatine scaffold did not result in significant functional improvement. Surprisingly, the improved motor performance was not correlated with the regeneration of lesioned axons through the implanted scaffold. This observation supports the notion that biomaterials may support functional recovery by mechanisms other than simple bridging of the lesion site, such as the local sprouting of injured, or even non-injured fibres
Cytocompatibility of a novel, longitudinally microstructured collagen scaffold intended for nerve tissue repair.
Traumatic injury to the nervous system induces functional deficits as a result of axonal destruction and the formation of scar tissue, cystic cavitation, and physical gaps. Bioengineering bridging materials should ideally act as cell carriers for the implantation of axon growth-promoting glia, as well as supporting integration with host cell types. Here, we describe the cytocompatibility of a novel, micro-structured porcine collagen scaffold containing densely packed and highly orientated channels that, in three-dimensional (3D) tissue culture, supports attachment, proliferation, aligned process extension, and directed migration by populations of glial cells (olfactory nerve ensheathing cells and astrocytes) and orientated axonal growth by neurons (differentiated human SH-SY5Y neuroblastoma cell line). The seeded glia required several weeks to penetrate deeply into the highly porous scaffold, where they adopted an orientated morphology similar to that displayed in simple 2D cultures. The direct interaction between SH-SY5Y-derived nerve fibers and the collagen scaffold also resulted in highly orientated axonal growth. It is likely that biocompatible scaffolds that are capable of promoting glial cell attachment, migration, and highly orientated process outgrowth will be important for future repair strategies for traumatically injured nervous tissues
Evaluation of functional nerve recovery with Visual-SSI : a novel computerized approach for the assessment of the static sciatic index (SSI)
Complete nerve transection (neurotmesis) of the rat sciatic nerve is a well-established animal model. The most frequently used behavioural for evaluation of neurotmesis-induced deficits is the walking track analysis with calculation of the sciatic functional index (SFI). More recently, the static sciatic index (SSI) has been developed, which shows a good correlation with the SFI. However, despite all advantages (high accessibility, easy handling, high accuracy, cost-effectiveness), the SSI is still not widely used. We, therefore, developed a novel programme ("Visual-SSI"), which will be made freely available for the assessment of the SSI. As gold-standard for the treatment of neurotmesis-induced nerve gaps, autologous nerve transplantation studies in the rat sciatic nerve model (n=16 [6 weeks], n=8 [12 weeks]) were carried out to test the effectiveness and feasibility of the Visual-SSI software. We observed a significant recovery starting from the pre-operative condition over the 3rd, 6th, 9th weeks until the 12th week after surgery (p0.05). The present method combines efficiency (simplicity of use, rapid and economical setup) with accurate and precise quantification of the functional regeneration in the sciatic nerve lesion model of the rat
The role of microstructured and interconnected pore channels in a collagen-based nerve guide on axonal regeneration in peripheral nerves
The use of bioengineered nerve guides as alternatives for autologous nerve transplantation (ANT) is a promising strategy for the repair of peripheral nerve defects. In the present investigation, we present a collagen-based micro-structured nerve guide (Perimaix) for the repair of 2 cm rat sciatic nerve defects. Perimaix is an open-porous biodegradable nerve guide containing continuous, longitudinally orientated channels for orientated nerve growth. The effects of these nerve guides on axon regeneration by six weeks after implantation have been compared with those of ANT. Investigation of the regenerated sciatic nerve indicated that Perimaix strongly supported directed axon regeneration. When seeded with cultivated rat Schwann cells (SC), the Perimaix nerve guide was found to be almost as supportive of axon regeneration as ANT. The use of SC from transgenic green-fluorescent-protein (GFP) rats allowed us to detect the viability of donor SC at 1 week and 6 weeks after tra nsplantation. The GFP-positive SC were aligned in a columnar fashion within the longitudinally orientated micro-channels. This cellular arrangement was not only observed prior to implantation, but also at one week and 6 weeks after implantation. It may be concluded that Perimaix nerve guides hold great promise for the repair of peripheral nerve defects