95 research outputs found

    Laparoscopic Left Adrenalectomy with Submesocolic and Retropancreatic Approach

    Get PDF
    Introduction: The safety and efficacy of laparoscopic transperitoneal lateral adrenalectomy and retroperitoneoscopic adrenalectomy have been reported. The aim is to report the authors’ experience in laparoscopic left adrenalectomy with an alternative transperitoneal submesocolic and retropancreatic approach with patient supine

    Induction chemotherapy followed by neoadjuvant chemoradiotherapy and surgery in locally advanced rectal cancer: preliminary results of a phase II study

    Get PDF
    PURPOSE: To report preliminary results of induction chemotherapy (IC) followed by neoadjuvant chemoradiotherapy (CRT) and surgery in locally advanced rectal cancer (LARC) patients.MATERIALS AND METHODS: This is the preliminary evaluation of a phase II study. Patients with histologically proven rectal adenocarcinoma, stage II-III disease, who met the inclusion criteria, received induction FOLFOXIRI (5-FU, leucovorin, oxaliplatin and irinotecan) regimen in combination with targeted agents followed by CRT and surgery. Analysis of the first 8 patients was required to confirm the treatment feasibility before the accrual of 20 additional patients. RESULTS: The first 8 patients were evaluated. The median follow-up time was 23 months. There were no treatment-related deaths. Trimodality strategy was well tolerated with high compliance and a good level of toxicity. There were no evidence of febrile neutropenia and any grade 4 adverse events were recorded. Three patients had pathologic complete response (pCR) and 1 patient had a nearly pCR (ypT1 ypN0). CONCLUSION: Preliminary results are encouraging. FOLFOXIRI regimen plus targeted agents followed by CRT and surgery seems a safe approach. Longer follow-up and higher number of patients are mandatory to confirm such findings

    CT colonography: Preliminary assessment of a double-read paradigm that uses computer-aided detection as the first reader

    Get PDF
    Purpose: To compare diagnostic performance and time efficiency of double-reading first-reader computer-aided detection (CAD) (DR FR CAD) followed by radiologist interpretation with that of an unassisted read using segmentally un-blinded colonoscopy as reference standard. Materials and Methods: The local ethical committee approved this study. Written consent to use examinations was obtained from patients. Three experienced radiologists searched for polyps 6 mm or larger in 155 computed tomographic (CT) colonographic studies (57 containing 10 masses and 79 polyps >= 6 mm). Reading was randomized to either unassisted read or DR FR CAD. Data sets were reread 6 weeks later by using the opposite paradigm. DR FR CAD consists of evaluation of CAD prompts, followed by fast two-dimensional review for mass detection. CAD sensitivity was calculated. Readers' diagnoses and reviewing times with and without CAD were compared by using McNemar and Student t tests, respectively. Association between missed polyps and lesion characteristics was explored with multiple regression analysis. Results: With mean rate of 19 (standard deviation, 14; median, 15; range, 4-127) false-positive results per patient, CAD sensitivity was 90% for lesions 6 mm or larger. Readers' sensitivity and specificity for lesions 6 mm or larger were 74% (95% confidence interval [CI]: 65%, 84%) and 93% (95% CI: 89%, 97%), respectively, for the unassisted read and 77% (95% CI: 67%, 85%) and 90% (95% CI: 85%, 95%), respectively, for DR FR CAD (P = .343 and P = .189, respectively). Overall unassisted and DR FR CAD reviewing times were similar (243 vs 239 seconds; P = .623); DR FR CAD was faster when the number of CAD marks per patient was 20 or fewer (187 vs 220 seconds, P < .01). Odds ratio of missing a polyp with CAD decreased as polyp size increased (0.6) and for polyps visible on both prone and supine scans (0.12); it increased for flat lesions (9.1). Conclusion: DR FR CAD paradigm had similar performance compared with unassisted interpretation but better time efficiency when 20 or fewer CAD prompts per patient were generated. (C) RSNA, 201

    Gravitational Waves From Known Pulsars: Results From The Initial Detector Era

    Get PDF
    We present the results of searches for gravitational waves from a large selection of pulsars using data from the most recent science runs (S6, VSR2 and VSR4) of the initial generation of interferometric gravitational wave detectors LIGO (Laser Interferometric Gravitational-wave Observatory) and Virgo. We do not see evidence for gravitational wave emission from any of the targeted sources but produce upper limits on the emission amplitude. We highlight the results from seven young pulsars with large spin-down luminosities. We reach within a factor of five of the canonical spin-down limit for all seven of these, whilst for the Crab and Vela pulsars we further surpass their spin-down limits. We present new or updated limits for 172 other pulsars (including both young and millisecond pulsars). Now that the detectors are undergoing major upgrades, and, for completeness, we bring together all of the most up-to-date results from all pulsars searched for during the operations of the first-generation LIGO, Virgo and GEO600 detectors. This gives a total of 195 pulsars including the most recent results described in this paper.United States National Science FoundationScience and Technology Facilities Council of the United KingdomMax-Planck-SocietyState of Niedersachsen/GermanyAustralian Research CouncilInternational Science Linkages program of the Commonwealth of AustraliaCouncil of Scientific and Industrial Research of IndiaIstituto Nazionale di Fisica Nucleare of ItalySpanish Ministerio de Economia y CompetitividadConselleria d'Economia Hisenda i Innovacio of the Govern de les Illes BalearsNetherlands Organisation for Scientific ResearchPolish Ministry of Science and Higher EducationFOCUS Programme of Foundation for Polish ScienceRoyal SocietyScottish Funding CouncilScottish Universities Physics AllianceNational Aeronautics and Space AdministrationOTKA of HungaryLyon Institute of Origins (LIO)National Research Foundation of KoreaIndustry CanadaProvince of Ontario through the Ministry of Economic Development and InnovationNational Science and Engineering Research Council CanadaCarnegie TrustLeverhulme TrustDavid and Lucile Packard FoundationResearch CorporationAlfred P. Sloan FoundationAstronom

    Different molecular mechanisms causing 9p21 deletions in acute lymphoblastic leukemia of childhood

    Get PDF
    Deletion of chromosome 9p21 is a crucial event for the development of several cancers including acute lymphoblastic leukemia (ALL). Double strand breaks (DSBs) triggering 9p21 deletions in ALL have been reported to occur at a few defined sites by illegitimate action of the V(D)J recombination activating protein complex. We have cloned 23 breakpoint junctions for a total of 46 breakpoints in 17 childhood ALL (9 B- and 8 T-lineages) showing different size deletions at one or both homologous chromosomes 9 to investigate which particular sequences make the region susceptible to interstitial deletion. We found that half of 9p21 deletion breakpoints were mediated by ectopic V(D)J recombination mechanisms whereas the remaining half were associated to repeated sequences, including some with potential for non-B DNA structure formation. Other mechanisms, such as microhomology-mediated repair, that are common in other cancers, play only a very minor role in ALL. Nucleotide insertions at breakpoint junctions and microinversions flanking the breakpoints have been detected at 20/23 and 2/23 breakpoint junctions, respectively, both in the presence of recombination signal sequence (RSS)-like sequences and of other unspecific sequences. The majority of breakpoints were unique except for two cases, both T-ALL, showing identical deletions. Four of the 46 breakpoints coincide with those reported in other cases, thus confirming the presence of recurrent deletion hotspots. Among the six cases with heterozygous 9p deletions, we found that the remaining CDKN2A and CDKN2B alleles were hypermethylated at CpG islands

    First searches for optical counterparts to gravitational-wave candidate events

    Get PDF
    During the Laser Interferometer Gravitational-wave Observatory and Virgo joint science runs in 2009-2010, gravitational wave (GW) data from three interferometer detectors were analyzed within minutes to select GW candidate events and infer their apparent sky positions. Target coordinates were transmitted to several telescopes for follow-up observations aimed at the detection of an associated optical transient. Images were obtained for eight such GW candidates. We present the methods used to analyze the image data as well as the transient search results. No optical transient was identified with a convincing association with any of these candidates, and none of the GW triggers showed strong evidence for being astrophysical in nature. We compare the sensitivities of these observations to several model light curves from possible sources of interest, and discuss prospects for future joint GW-optical observations of this type

    Searching for stochastic gravitational waves using data from the two colocated LIGO Hanford detectors

    Get PDF
    Searches for a stochastic gravitational-wave background (SGWB) using terrestrial detectors typically involve cross-correlating data from pairs of detectors. The sensitivity of such cross-correlation analyses depends, among other things, on the separation between the two detectors: the smaller the separation, the better the sensitivity. Hence, a colocated detector pair is more sensitive to a gravitational-wave background than a noncolocated detector pair. However, colocated detectors are also expected to suffer from correlated noise from instrumental and environmental effects that could contaminate the measurement of the background. Hence, methods to identify and mitigate the effects of correlated noise are necessary to achieve the potential increase in sensitivity of colocated detectors. Here we report on the first SGWB analysis using the two LIGO Hanford detectors and address the complications arising from correlated environmental noise. We apply correlated noise identification and mitigation techniques to data taken by the two LIGO Hanford detectors, H1 and H2, during LIGO’s fifth science run. At low frequencies, 40–460 Hz, we are unable to sufficiently mitigate the correlated noise to a level where we may confidently measure or bound the stochastic gravitational-wave signal. However, at high frequencies, 460–1000 Hz, these techniques are sufficient to set a 95% confidence level upper limit on the gravitational-wave energy density of Ω(f) < 7.7 × 10[superscript -4](f/900  Hz)[superscript 3], which improves on the previous upper limit by a factor of ~180. In doing so, we demonstrate techniques that will be useful for future searches using advanced detectors, where correlated noise (e.g., from global magnetic fields) may affect even widely separated detectors.National Science Foundation (U.S.)United States. National Aeronautics and Space AdministrationCarnegie TrustDavid & Lucile Packard FoundationAlfred P. Sloan Foundatio
    • …
    corecore