9 research outputs found

    Safety and reliability of Radio Frequency Identification Devices in Magnetic Resonance Imaging and Computed Tomography

    Get PDF
    BACKGROUND: Radio Frequency Identification (RFID) devices are becoming more and more essential for patient safety in hospitals. The purpose of this study was to determine patient safety, data reliability and signal loss wearing on skin RFID devices during magnetic resonance imaging (MRI) and computed tomography (CT) scanning. METHODS: Sixty RFID tags of the type I-Code SLI, 13.56 MHz, ISO 18000-3.1 were tested: Thirty type 1, an RFID tag with a 76 x 45 mm aluminum-etched antenna and 30 type 2, a tag with a 31 x 14 mm copper-etched antenna. The signal loss, material movement and heat tests were performed in a 1.5 T and a 3 T MR system. For data integrity, the tags were tested additionally during CT scanning. Standardized function tests were performed with all transponders before and after all imaging studies. RESULTS: There was no memory loss or data alteration in the RFID tags after MRI and CT scanning. Concerning heating (a maximum of 3.6 degrees C) and device movement (below 1 N/kg) no relevant influence was found. Concerning signal loss (artifacts 2 - 4 mm), interpretability of MR images was impaired when superficial structures such as skin, subcutaneous tissues or tendons were assessed. CONCLUSIONS: Patients wearing RFID wristbands are safe in 1.5 T and 3 T MR scanners using normal operation mode for RF-field. The findings are specific to the RFID tags that underwent testing

    Functional outcome after perineal stapled prolapse resection for external rectal prolapse

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A new surgical technique, the Perineal Stapled Prolapse resection (PSP) for external rectal prolapse was introduced in a feasibility study in 2008. This study now presents the first results of a larger patient group with functional outcome in a mid-term follow-up.</p> <p>Methods</p> <p>From December 2007 to April 2009 PSP was performed by the same surgeon team on patients with external rectal prolapse. The prolapse was completely pulled out and then axially cut open with a linear stapler at three and nine o'clock in lithotomy position. Finally, the prolapse was resected stepwise with the curved Contour<sup>® </sup>Transtar™ stapler at the prolapse's uptake. Perioperative morbidity and functional outcome were prospectively measured by appropriate scores.</p> <p>Results</p> <p>32 patients participated in the study; median age was 80 years (range 26-93). No intraoperative complications and 6.3% minor postoperative complications occurred. Median operation time was 30 minutes (15-65), hospital stay 5 days (2-19). Functional outcome data were available in 31 of the patients after a median follow-up of 6 months (4-22). Preoperative severe faecal incontinence disappeared postoperatively in 90% of patients with a reduction of the median Wexner score from 16 (4-20) to 1 (0-14) (<it>P </it>< 0.0001). No new incidence of constipation was reported.</p> <p>Conclusions</p> <p>The PSP is an elegant, fast and safe procedure, with good functional results.</p> <p>Trial registration</p> <p>ISRCTN68491191</p

    Stapled vs Excision Hemorrhoidectomy

    No full text

    Safety and reliability of Radio Frequency Identification Devices in Magnetic Resonance Imaging and Computed Tomography

    No full text
    Abstract Background Radio Frequency Identification (RFID) devices are becoming more and more essential for patient safety in hospitals. The purpose of this study was to determine patient safety, data reliability and signal loss wearing on skin RFID devices during magnetic resonance imaging (MRI) and computed tomography (CT) scanning. Methods Sixty RFID tags of the type I-Code SLI, 13.56 MHz, ISO 18000-3.1 were tested: Thirty type 1, an RFID tag with a 76 × 45 mm aluminum-etched antenna and 30 type 2, a tag with a 31 × 14 mm copper-etched antenna. The signal loss, material movement and heat tests were performed in a 1.5 T and a 3 T MR system. For data integrity, the tags were tested additionally during CT scanning. Standardized function tests were performed with all transponders before and after all imaging studies. Results There was no memory loss or data alteration in the RFID tags after MRI and CT scanning. Concerning heating (a maximum of 3.6°C) and device movement (below 1 N/kg) no relevant influence was found. Concerning signal loss (artifacts 2 - 4 mm), interpretability of MR images was impaired when superficial structures such as skin, subcutaneous tissues or tendons were assessed. Conclusions Patients wearing RFID wristbands are safe in 1.5 T and 3 T MR scanners using normal operation mode for RF-field. The findings are specific to the RFID tags that underwent testing.</p

    Decision-making algorithm for the STARR procedure in obstructed defecation syndrome: position statement of the group of STARR pioneers

    No full text
    Internal rectal prolapse (rectal intussusception) and rectocele are frequent clinical findings in patients suffering from refractory constipation that may be best characterized as obstructive defecation syndrome. However, there is still no clear evidence whether the stapled transanal rectal resection (STARR) procedure provides a safe and effective surgical option for symptom resolution in patients with obstructive defecation syndrome, as evidence-based guidelines and functional long-term results are still missing. On the basis of the need for objective evaluation, a European group of experts was founded (Stapled Transanal Rectal Resection Pioneers). Derived from 2 meetings (October 26-28, 2006, Gouvieux, France and November 28-29, 2007, St Gallen, Switzerland) a concept for treatment options in patients suffering from obstructive defecation syndrome was developed, including a clear decision-making algorithm specifically focusing on the role of the stapled transanal rectal resection procedure based on clinical symptoms and dynamic imaging and inclusion and exclusion criteria for the stapled transanal rectal resection procedure

    A novel approach for treatment of sacrococcygeal pilonidal sinus: less is more

    Full text link
    BACKGROUND: The surgical management of sacrococcygeal pilonidal sinus (PS) is still a matter of discussion. Therapy ranges from complete wide excision with or without closure of the wound to excochleation of the sinus with a brush. In this paper, we introduce a novel limited excision technique. The aim of this study was to assess the morbidity and recurrence rate of this technique. MATERIALS AND METHODS: Limited excision consisted of a selective extirpation of the sinus after tagging the tract with methylene blue. Ninety-three consecutive patients, who underwent surgery between 2001 and 2004, were analyzed. The patients' survey was performed by mail questionnaire and telephone interview inquiring recurrence, time off work, and time to wound healing. RESULTS: Seventy-three percent of the patients were treated in an outpatient setting. With a median follow-up of 2 years, the recurrence rate was 5%. The median time off work was 2 weeks. The median wound healing time was 5 weeks. CONCLUSION: Limited excision for PS can be done in an outpatient setting with a low recurrence rate and short time off work

    ABSTRACTS

    No full text
    corecore