3,530 research outputs found

    Charmed particle production and decay in a high energy photoproduction experiment

    Get PDF
    Imperial Users onl

    Standalone Track Reconstruction in the T-stations

    Get PDF
    An algorithm for fast and efficient tracking in the T-stations is describedtogether with its performance in the DC06 data challenge. An efficiency of94--95 %95~\% is achieved for tracks with momenta above 2~GeV for a ghost rate of 13 %13~\%

    Updated Performance of the T-Seeding

    Get PDF
    Improvements to the performance of the track seeding since the start of the DC '06 data challenge are described. For tracks above 2~GeV an efficiency of 96.3 %96.3~\% is achieved for a ghost rate of 8.1~\%. In addition, the expected performance of the algorithm during the 2007 pilot run is discussed

    TORCH: A Cherenkov Based Time-of-Flight Detector

    Get PDF
    TORCH is a novel high-precision time-of-flight detector suitable for large area applications and covering the momentum range up to 10 GeV/c. The concept uses Cherenkov photons produced in a fused silica radiator which are propagated to focussing optics coupled to fast photodetectors. For this purpose, custom MCP-PMTs are being produced in collaboration with industrial partners. The development is divided into three phases. Phase 1 addresses the lifetime requirements for TORCH, Phase 2 will customize the MCP-PMT granularity and Phase 3 will deliver prototypes that meet the TORCH requirements. Phase 1 devices have been successfully delivered and initial tests show stable gain performance for integrated anode current >5 C/cm2 and a single photon time resolution of ≀ 30 ps. Initial simulations indicate the single photon timing resolution of the TORCH detector will be ∌70 ps

    Analysis and correction of the magnetic field effects in the Hybrid Photo-Detectors of the RICH2 Ring Imaging Cherenkov detector of LHCb

    Full text link
    The Ring Imaging Cherenkov detectors of the LHCb experiment at the Large Hadron Collider at CERN are equipped with Hybrid Photo-Detectors. These vacuum photo-detectors are affected by the stray magnetic field of the LHCb magnet, which degrades their imaging properties. This effect increases the error on the Cherenkov angle measurement and would reduce the particle identification capabilities of LHCb. A system has been developed for the RICH2 Ring Imaging Cherenkov detector to perform a detailed characterisation of the magnetic distortion effects. It is described, along with the methods implemented to correct for these effects, restoring the optimal resolution.Comment: 16 pages, 11 figure

    Two body decays of the bb-quark: Applications to direct CP violation, searches for electro-weak penguins and new physics

    Get PDF
    A systematic experimental search for two-body hadronic decays of the b-quark of the type b to quark + meson is proposed. These reactions have a well defined experimental signature and they should be theoretically cleaner compared to exclusive decays. Many modes have appreciable branching ratios and partial rate asymmetries may also be quite large (about 8-50%) in several of them. In a few cases electroweak penguins appear to be dominant and may be measurable. CP violating triple correlation asymmetries provide a clean test of the Standard Model.Comment: 12 pages 1 figure 1 tabl

    A Comment on the Experimental Determination of ∣Vts/Vtd∣2|V_{ts}/V_{td}|^2.

    Get PDF
    We propose a method to extract the ratio ∣Vts/Vtd∣2|V_{ts}/V_{td}|^2 from a measurement of ΔΓ/Γ\Delta \Gamma/\Gamma for the BsB_s meson. This method is experimentally more sensitive than the conventional method for large values of ∣Vts∣|V_{ts}| but depends on the accuracy of parton level calculations.Comment: 6 pages, LATEX forma

    Averaging lifetimes for B hadron species

    Get PDF
    The measurement of the lifetimes of the individual B species are of great interest. Many of these measurements are well below the 10 %\% level of precision. However, in order to reach the precision necessary to test the current theoretical predictions, the results from different experiments need to be averaged. Therefore, the relevant systematic uncertainties of each measurement need to be well defined in order to understand the correlations between the results from different experiments. \par In this paper we discuss the dominant sources of systematic errors which lead to correlations between the different measurements. We point out problems connected with the conventional approach of combining lifetime data and discuss methods which overcome these problems

    Monochromatic Propagation-Based Phase-Contrast Microscale Computed-Tomography System with a Rotating-Anode Source

    Get PDF
    We present an experimental setup for monochromatic propagation-based x-ray phase-contrast imaging based on a conventional rotating-copper-anode source, capable of an integrated flux up to 108 photons/s at 8 keV. In our study, the system is characterized in terms of spatial coherence, resolution, contrast sensitivity, and stability. Its quantitativeness is demonstrated by comparing theoretical predictions with experimental data on simple wire phantoms both in planar and computerized-tomography-scan geometries. Application to two biological samples of medical interest shows the potential for bioimaging on the millimeter scale with spatial resolution of the order of 10 \u3bcm and contrast resolution below 1%. All the scans are performed within laboratory-compatible exposure times, from 10 min to a few hours, and trade-offs between scan time and image quality are discussed

    TORCH: A Cherenkov Based Time-of-Flight Detector

    Get PDF
    TORCH is a novel high-precision time-of-flight detector suitable for large area applications and covering the momentum range up to 10 GeV/c. The concept uses Cherenkov photons produced in a fused silica radiator which are propagated to focussing optics coupled to fast photodetectors. For this purpose, custom MCP-PMTs are being produced in collaboration with industrial partners. The development is divided into three phases. Phase 1 addresses the lifetime requirements for TORCH, Phase 2 will customize the MCP-PMT granularity and Phase 3 will deliver prototypes that meet the TORCH requirements. Phase 1 devices have been successfully delivered and initial tests show stable gain performance for integrated anode current >5 C/cm2 and a single photon time resolution of ≀ 30 ps. Initial simulations indicate the single photon timing resolution of the TORCH detector will be ∌70 ps
    • 

    corecore