3 research outputs found

    Multimodal validation of focal enhancement in intracranial aneurysms as a surrogate marker for aneurysm instability

    Full text link
    Purpose!#!Circumferential enhancement on MR vessel wall imaging has been proposed as a biomarker of a higher risk of rupture in intracranial aneurysms. Focal enhancement is frequently encountered in unruptured aneurysms, but its implication for risk stratification and patient management remains unclear. This study investigates the association of focal wall enhancement with hemodynamic and morphological risk factors and histologic markers of wall inflammation and degeneration.!##!Methods!#!Patients with an unruptured middle cerebral artery aneurysm who underwent 3D rotational angiography and 3T MR vessel wall imaging showing focal wall enhancement were included. Hemodynamic parameters were calculated based on flow simulations and compared between enhanced regions and the entire aneurysm surface. Morphological parameters were semiautomatically extracted and quantitatively associated with wall enhancement. Histological analysis included detection of vasa vasorum, CD34, and myeloperoxidase staining in a subset of patients.!##!Results!#!Twenty-two aneurysms were analyzed. Enhanced regions were significantly associated with lower AWSS, lower maxOSI, and increased LSA. In multivariate analysis, higher ellipticity index was an independent predictor of wall enhancement. Histologic signs of inflammation and degeneration and higher PHASES score were significantly associated with focal enhancement.!##!Conclusion!#!Focal wall enhancement is colocalized with hemodynamic factors that have been related to a higher rupture risk. It is correlated with morphological factors linked to rupture risk, higher PHASES score, and histologic markers of wall destabilization. The results support the hypothesis that focal enhancement could serve as a surrogate marker for aneurysm instability

    Effectiveness of an annular closure device to prevent recurrent lumbar disc herniation a secondary analysis with 5 years of follow-up

    Full text link
    IMPORTANCE: Patients with large annular defects following lumbar microdiscectomy for disc herniation are at increased risk for symptomatic recurrence and reoperation. OBJECTIVE: To determine whether a bone-anchored annular closure device in addition to lumbar microdiscectomy resulted in lower reherniation and reoperation rates vs lumbar microdiscectomy alone. DESIGN, SETTING, AND PARTICIPANTS: This secondary analysis of a multicenter randomized clinical trial reports 5-year follow-up for enrolled patients between December 2010 and October 2014 at 21 clinical sites. Patients in this study had a large annular defect (6-10 mm width) following lumbar microdiscectomy for treatment of lumbar disc herniation. Statistical analysis was performed from November to December 2020. INTERVENTIONS: Lumbar microdiscectomy with additional bone-anchored annular closure device (device group) or lumbar microdiscectomy only (control group). MAIN OUTCOMES AND MEASURES: The incidence of symptomatic reherniation, reoperation, and adverse events as well as changes in leg pain, Oswestry Disability Index, and health-related quality of life when comparing the device and control groups over 5 years of follow-up. RESULTS: Among 554 randomized participants (mean [SD] age: 43 [11] years; 327 [59%] were men), 550 were included in the modified intent-to-treat efficacy population (device group: n = 272; 270 [99%] were White); control group: n = 278; 273 [98%] were White) and 550 were included in the as-treated safety population (device group: n = 267; control group: n = 283). The risk of symptomatic reherniation (18.8% [SE, 2.5%] vs 31.6% [SE, 2.9%]; P < .001) and reoperation (16.0% [SE, 2.3%] vs 22.6% [SE, 2.6%]; P = .03) was lower in the device group. There were 53 reoperations in 40 patients in the device group and 82 reoperations in 58 patients in the control group. Scores for leg pain severity, Oswestry Disability Index, and health-related quality of life significantly improved over 5 years of follow-up with no clinically relevant differences between groups. The frequency of serious adverse events was comparable between the treatment groups. Serious adverse events associated with the device or procedure were less frequent in the device group (12.0% vs 20.5%; difference, −8.5%; 95% CI, −14.6% to −2.3%; P = .008). CONCLUSIONS AND RELEVANCE: In patients who are at high risk of recurrent herniation following lumbar microdiscectomy owing to a large defect in the annulus fibrosus, this study’s findings suggest that annular closure with a bone-anchored implant lowers the risk of symptomatic recurrence and reoperation over 5 years of follow-up. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0128343
    corecore