6 research outputs found
Recommended from our members
Green Buildings and Health
Green building design is becoming broadly adopted, with one green building standard reporting over 3.5 billion square feet certified to date. By definition, green buildings focus on minimizing impacts to the environment through reductions in energy usage, water usage, and minimizing environmental disturbances from the building site. Also by definition, but perhaps less widely recognized, green buildings aim to improve human health through design of healthy indoor environments. The benefits related to reduced energy and water consumption are well-documented, but the potential human health benefits of green buildings are only recently being investigated. The objective of our review was to examine the state of evidence on green building design as it specifically relates to indoor environmental quality and human health. Overall, the initial scientific evidence indicates better indoor environmental quality in green buildings versus non-green buildings, with direct benefits to human health for occupants of those buildings. A limitation of much of the research to date is the reliance on indirect, lagging and subjective measures of health. To address this, we propose a framework for identifying direct, objective and leading âHealth Performance Indicatorsâ for use in future studies of buildings and health
Recommended from our members
Response to âComment on âFlavoring Chemicals in E-Cigarettes: Diacetyl, 2,3-Pentanedione, and Acetoin in a Sample of 51 Products, Including Fruit-, Candy-, and Cocktail-Flavored E-Cigarettesââ
Recommended from our members
Flavoring Chemicals in E-Cigarettes: Diacetyl, 2,3-Pentanedione, and Acetoin in a Sample of 51 Products, Including Fruit-, Candy-, and Cocktail-Flavored E-Cigarettes
Background: There are > 7,000 e-cigarette flavors currently marketed. Flavoring chemicals gained notoriety in the early 2000s when inhalation exposure of the flavoring chemical diacetyl was found to be associated with a disease that became known as âpopcorn lung.â There has been limited research on flavoring chemicals in e-cigarettes. Objective: We aimed to determine if the flavoring chemical diacetyl and two other high-priority flavoring chemicals, 2,3-pentanedione and acetoin, are present in a convenience sample of flavored e-cigarettes. Methods: We selected 51 types of flavored e-cigarettes sold by leading e-cigarette brands and flavors we deemed were appealing to youth. E-cigarette contents were fully discharged and the air stream was captured and analyzed for total mass of diacetyl, 2,3-pentanedione, and acetoin, according to OSHA method 1012. Results: At least one flavoring chemical was detected in 47 of 51 unique flavors tested. Diacetyl was detected above the laboratory limit of detection in 39 of the 51 flavors tested, ranging from below the limit of quantification to 239 ÎŒg/e-cigarette. 2,3-Pentanedione and acetoin were detected in 23 and 46 of the 51 flavors tested at concentrations up to 64 and 529 ÎŒg/e-cigarette, respectively. Conclusion: Because of the associations between diacetyl and bronchiolitis obliterans and other severe respiratory diseases observed in workers, urgent action is recommended to further evaluate this potentially widespread exposure via flavored e-cigarettes. Citation: Allen JG, Flanigan SS, LeBlanc M, Vallarino J, MacNaughton P, Stewart JH, Christiani DC. 2016. Flavoring chemicals in e-cigarettes: diacetyl, 2,3-pentanedione, and acetoin in a sample of 51 products, including fruit-, candy-, and cocktail-flavored e-cigarettes. Environ Health Perspect 124:733â739; http://dx.doi.org/10.1289/ehp.151018
Associations between acute exposures to PM2.5 and carbon dioxide indoors and cognitive function in office workers: a multicountry longitudinal prospective observational study
Despite evidence of the air pollution effects on cognitive function, little is known about the acute impact of indoor air pollution on cognitive function among the working-age population. We aimed to understand whether cognitive function was associated with real-time indoor concentrations of particulate matter (PM _2.5 ) and carbon dioxide (CO _2 ). We conducted a prospective observational longitudinal study among 302 office workers in urban commercial buildings located in six countries (China, India, Mexico, Thailand, the United States of America, and the United Kingdom). For 12 months, assessed cognitive function using the Stroop color-word test and additionâsubtraction test (ADD) via a mobile research app. We found that higher PM _2.5 and lower ventilation rates, as assessed by CO _2 concentration, were associated with slower response times and reduced accuracy (fewer correct responses per minute) on the Stroop and ADD for eight out ten test metrics. Each interquartile (IQR) increase in PM _2.5 (IQR = 8.8 g m ^â3 ) was associated with a 0.82% (95% CI: 0.42, 1.21) increase in Stroop response time, a 6.18% (95% CI: 2.08, 10.3) increase in Stroop interference time, a 0.7% (95% CI: â1.38, â0.01) decrease in Stroop throughput, and a 1.51% (95% CI: â2.65, â0.37) decrease in ADD throughput. For CO _2 , an IQR increase (IQR = 315 ppm) was associated with a 0.85% (95% CI: 0.32, 1.39) increase in Stroop response time, a 7.88% (95% CI: 2.08, 13.86) increase in Stroop interference time, a 1.32% (95% CI: â2.3, â0.38) decrease in Stroop throughput, and a 1.13% (95% CI: 0.18, 2.11) increase in ADD response time. A sensitivity analysis showed significant association between PM _2.5 in four out of five cognitive test performance metrics only at levels above 12 g m ^â3 . Enhanced filtration and higher ventilation rates that exceed current minimum targets are essential public health strategies that may improve employee productivity