116 research outputs found
Recommended from our members
A study of the suitability of developing a local in-service program using the in-basket simulation technique.
EducationDoctor of Education (Ed.D.
Resolving the inner jet structure of 1924-292 with the EVENT HORIZON TELESCOPE
We present the first 1.3 mm (230 GHz) very long baseline interferometry model
image of an AGN jet using closure phase techniques with a four-element array.
The model image of the quasar 1924-292 was obtained with four telescopes at
three observatories: the James Clerk Maxwell Telescope (JCMT) on Mauna Kea in
Hawaii, the Arizona Radio Observatory's Submillimeter Telescope (SMT) in
Arizona, and two telescopes of the Combined Array for Research in
Millimeterwave Astronomy (CARMA) in California in April 2009. With the greatly
improved resolution compared with previous observations and robust closure
phase measurement, the inner jet structure of 1924-292 was spatially resolved.
The inner jet extends to the northwest along a position angle of at
a distance of 0.38\,mas from the tentatively identified core, in agreement with
the inner jet structure inferred from lower frequencies, and making a position
angle difference of with respect to the cm-jet. The size of
the compact core is 0.15\,pc with a brightness temperature of
\,K. Compared with those measured at lower frequencies, the
low brightness temperature may argue in favor of the decelerating jet model or
particle-cascade models. The successful measurement of closure phase paves the
way for imaging and time resolving Sgr A* and nearby AGN with the Event Horizon
Telescope.Comment: 6 pages, 4 figures, accepted for publication in ApJ
1.3 mm Wavelength VLBI of Sagittarius A*: Detection of Time-Variable Emission on Event Horizon Scales
Sagittarius A*, the ~4 x 10^6 solar mass black hole candidate at the Galactic
Center, can be studied on Schwarzschild radius scales with (sub)millimeter
wavelength Very Long Baseline Interferometry (VLBI). We report on 1.3 mm
wavelength observations of Sgr A* using a VLBI array consisting of the JCMT on
Mauna Kea, the ARO/SMT on Mt. Graham in Arizona, and two telescopes of the
CARMA array at Cedar Flat in California. Both Sgr A* and the quasar calibrator
1924-292 were observed over three consecutive nights, and both sources were
clearly detected on all baselines. For the first time, we are able to extract
1.3 mm VLBI interferometer phase information on Sgr A* through measurement of
closure phase on the triangle of baselines. On the third night of observing,
the correlated flux density of Sgr A* on all VLBI baselines increased relative
to the first two nights, providing strong evidence for time-variable change on
scales of a few Schwarzschild radii. These results suggest that future VLBI
observations with greater sensitivity and additional baselines will play a
valuable role in determining the structure of emission near the event horizon
of Sgr A*.Comment: 8 pages, submitted to ApJ
C5 Palsy After Cervical Spine Surgery: A Multicenter Retrospective Review of 59 Cases.
STUDY DESIGN: A multicenter, retrospective review of C5 palsy after cervical spine surgery.
OBJECTIVE: Postoperative C5 palsy is a known complication of cervical decompressive spinal surgery. The goal of this study was to review the incidence, patient characteristics, and outcome of C5 palsy in patients undergoing cervical spine surgery.
METHODS: We conducted a multicenter, retrospective review of 13 946 patients across 21 centers who received cervical spine surgery (levels C2 to C7) between January 1, 2005, and December 31, 2011, inclusive. P values were calculated using 2-sample t test for continuous variables and χ(2) tests or Fisher exact tests for categorical variables.
RESULTS: Of the 13 946 cases reviewed, 59 patients experienced a postoperative C5 palsy. The incidence rate across the 21 sites ranged from 0% to 2.5%. At most recent follow-up, 32 patients reported complete resolution of symptoms (54.2%), 15 had symptoms resolve with residual effects (25.4%), 10 patients did not recover (17.0%), and 2 were lost to follow-up (3.4%).
CONCLUSION: C5 palsy occurred in all surgical approaches and across a variety of diagnoses. The majority of patients had full recovery or recovery with residual effects. This study represents the largest series of North American patients reviewed to date
Detection of intrinsic source structure at ~3 Schwarzschild radii with Millimeter-VLBI observations of SAGITTARIUS A*
We report results from very long baseline interferometric (VLBI) observations
of the supermassive black hole in the Galactic center, Sgr A*, at 1.3 mm (230
GHz). The observations were performed in 2013 March using six VLBI stations in
Hawaii, California, Arizona, and Chile. Compared to earlier observations, the
addition of the APEX telescope in Chile almost doubles the longest baseline
length in the array, provides additional {\it uv} coverage in the N-S
direction, and leads to a spatial resolution of 30 as (3
Schwarzschild radii) for Sgr A*. The source is detected even at the longest
baselines with visibility amplitudes of 4-13% of the total flux density.
We argue that such flux densities cannot result from interstellar refractive
scattering alone, but indicate the presence of compact intrinsic source
structure on scales of 3 Schwarzschild radii. The measured nonzero
closure phases rule out point-symmetric emission. We discuss our results in the
context of simple geometric models that capture the basic characteristics and
brightness distributions of disk- and jet-dominated models and show that both
can reproduce the observed data. Common to these models are the brightness
asymmetry, the orientation, and characteristic sizes, which are comparable to
the expected size of the black hole shadow. Future 1.3 mm VLBI observations
with an expanded array and better sensitivity will allow a more detailed
imaging of the horizon-scale structure and bear the potential for a deep
insight into the physical processes at the black hole boundary.Comment: 11 pages, 5 figures, accepted to Ap
Gravitational Test beyond the First Post-Newtonian Order with the Shadow of the M87 Black Hole
The 2017 Event Horizon Telescope (EHT) observations of the central source in M87 have led to the first measurement of the size of a black-hole shadow. This observation offers a new and clean gravitational test of the black-hole metric in the strong-field regime. We show analytically that spacetimes that deviate from the Kerr metric but satisfy weak-field tests can lead to large deviations in the predicted black-hole shadows that are inconsistent with even the current EHT measurements. We use numerical calculations of regular, parametric, non-Kerr metrics to identify the common characteristic among these different parametrizations that control the predicted shadow size. We show that the shadow-size measurements place significant constraints on deviation parameters that control the second post-Newtonian and higher orders of each metric and are, therefore, inaccessible to weak-field tests. The new constraints are complementary to those imposed by observations of gravitational waves from stellar-mass sources
- …