353 research outputs found

    Surgical left atrial appendage occlusion: evaluation of a novel device with magnetic resonance imaging

    Get PDF
    Objective: Management of the left atrial appendage (LAA) is considered an important adjunct to ablation in cardiac surgical patients with atrial fibrillation (AF). However, current surgical techniques, both cut-and-sew and stapling, have been associated with incomplete LAA occlusion and complications. Using cardiac magnetic resonance imaging (MRI), we studied the safety and effectiveness of a new device for LAA occlusion in a primate model. Methods: Seven adult baboons underwent off-pump placement of an LAA clip (AtriCure Inc., Westchester, Ohio). LAA occlusion was confirmed intraoperatively by direct incision. All animals had MRI before and after clip placement to assess LAA perfusion, architecture, and overall cardiac function. Pathologic and histological studies were performed at 7, 30 and 180 days. Results: Clip placement was successful in all (n=7) without any clip related complications. Complete LAA occlusion was demonstrated intraoperatively in all subjects. LAA occlusion was confirmed on pre-sacrifice MRI, and left and right ventricular function were unchanged from preoperative studies; however, clip placement caused small reductions in left ventricular end-diastolic, end-systolic, and stroke volumes. At sacrifice, direct inspection confirmed stable location, persistent LAA exclusion, tissue in-growth and homogenous epithelialization without damage to adjacent structures. Histological analysis revealed a regular in-growth pattern in all studied specimens. Conclusion: We demonstrated a safe, straightforward, persistent and effective method for LAA occlusion with this new LAA clip. MRI effectively demonstrated LAA occlusion and only minor changes in left ventricular volume

    Automated distal coronary bypass with a novel magnetic coupler (MVP system)

    Get PDF
    AbstractObjectiveWe sought to assess the feasibility of performing sutureless distal coronary artery bypass anastomoses with a novel magnetic coupling device.MethodsFrom May 2000 to April 2001, single-vessel side-to-side coronary artery bypass grafting on a beating heart was performed in 39 domestic white pigs (35-60 kg) without the use of mechanical stabilization, shunts, or perfusion bridges. Animals were divided into 2 groups. Seventeen pigs underwent right internal thoracic artery to right coronary artery bypass grafting through a median sternotomy (group 1) with a novel magnetic vascular positioning system (MVP system; Ventrica, Inc, Fremont, Calif). Twenty-two pigs underwent left internal thoracic artery to left anterior descending artery grafting with the MVP anastomotic device through a left anterior minithoracotomy (group 2). This system consists of 2 pairs of elliptical magnetic implants and a deployment device. One pair of magnets forms the anastomotic docking port within the graft; the other pair forms an identical anastomotic docking port within the target vessel. The anastomosis is created when the 2 docking ports magnetically couple. Anastomotic patency was evaluated by means of angiography during the first postoperative week and at 1 month. Histologic studies were performed at different time points as late as 6 months.ResultsRight internal thoracic artery to right coronary artery anastomoses and left internal thoracic artery to left anterior descending artery anastomoses were successfully performed with the system in all animals. The self-adherent and self-aligning properties of the implants allowed for immediate and secure approximation of the arteries (total anastomotic time between 2-3 minutes). Anastomoses were constructed without a stabilization platform. Five nondevice-related deaths occurred postoperatively. One-week angiography, performed in 35 surviving animals, showed a patent graft and anastomosis in all cases. The patency rate at 1 month was 97% (33/34). Histologic studies as late as 6 months demonstrated neointimal coverage of the magnets without any significant luminal obstruction. Histology also confirmed the presence of viable tissue between magnets.ConclusionThe MVP anastomotic system uses magnetic force to create rapid and secure distal coronary artery anastomoses, which might facilitate minimally invasive and totally endoscopic coronary artery bypass surgery

    Revival of the side-to-side approach for distal coronary anastomosis

    Get PDF
    Side-to-side anastomosis was employed by just ten proportional stitches while performing distal anastomosis during coronary artery surgery. This technique is simple and quick. Here this simple technique is described in detail and the postoperative status of grafted conduits is reported

    Risk Factors For Recurrent Stroke After Coronary Artery Bypass Grafting

    Get PDF
    <p>Abstract</p> <p>Objectives</p> <p>Preventing stroke after coronary artery bypass grafting (CABG) remains a therapeutic goal, due in part to the lack of identifiable risk factors. The aim of this study, accordingly, was to identify risk factors in CABG patients with a previous history of stroke.</p> <p>Methods</p> <p>Patients with a history of stroke who underwent CABG at Beijing An Zhen hospital from January 2007 to July 2010 were selected (n = 430), and divided into two groups according to the occurrence of postoperative stroke. Pre-operative and post-operative data were retrospectively collected and analyzed by univariate and multivariate logistic regression analyses.</p> <p>Results</p> <p>Thirty-two patients (7.4%) suffered post-operative stroke. Univariate analysis identified several statistically significant risk factors in the post-operative stroke group, including pre-surgical left ventricular ejection fractions (LVEF) ≤50%, on-pump surgery, post-operative atrial fibrillation (AF), and hypotension. Multivariable analysis identified 4 independent risk factors for recurrent stroke: unstable angina (odds ratio (OR) = 2.95, 95% CI: 1.05-8.28), LVEF ≤50% (OR = 2.77, 95% CI: 1.23-6.27), AF (OR = 4.69, 95% CI: 1.89-11.63), and hypotension (OR = 2.55, 95% CI: 1.07-6.04).</p> <p>Conclusion</p> <p>Unstable angina, LVEF ≤50%, post-operative AF, and post-operative hypotension are independent risk factors of recurrent stroke in CABG patients with a previous history of stroke.</p

    Intestinal ischemia after cardiac surgery: analysis of a large registry.

    Get PDF
    Intestinal ischemia after cardiac surgery is a rare but severe complication with a high mortality. Early surgery can be lifesaving. The aim was to analyze the incidence, outcome, and risk factors for these patients

    Evolving Indications for Tricuspid Valve Surgery

    Get PDF
    More attention has been paid to the mitral valve (MV) than the tricuspid valve (TV), and this relative paucity of data has led to confusion regarding the timing of TV surgery. We review the American College of Cardiology/American Heart Association and European Society of Cardiology guidelines to identify areas of concordance (severe tricuspid regurgitation [TR] in a patient undergoing mitral valve surgery); discordance (less than severe TR but with markers for late TR recurrence such as pulmonary hypertension, a dilated TV annulus, atrial fibrillation, permanent transtricuspid pacing wires and others); and disagreement (surgery for primary TR). We provide our perspective from Northwestern University on these issues and where the guidelines are silent (TR in patients undergoing non-mitral valve operations). Finally, we review recent publications on the results of TV repair and replacement. Although there have been scant publications in the past, there have been more useful publications in recent years to guide our decision making

    Are there independent predisposing factors for postoperative infections following open heart surgery?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Nosocomial infections after cardiac surgery represent serious complications associated with substantial morbidity, mortality and economic burden. This study was undertaken to evaluate the frequency, characteristics, and risk factors of microbiologically documented nosocomial infections after cardiac surgery in a Cardio-Vascular Intensive Care Unit (CVICU).</p> <p>Methods</p> <p>All patients who underwent open heart surgery between May 2006 and March 2008 were enrolled in this prospective study. Pre-, intra- and postoperative variables were collected and examined as possible risk factors for development of nosocomial infections. The diagnosis of infection was always microbiologically confirmed.</p> <p>Results</p> <p>Infection occurred in 24 of 172 patients (13.95%). Out of 172 patients, 8 patients (4.65%) had superficial wound infection at the sternotomy site, 5 patients (2.9%) had central venous catheter infection, 4 patients (2.32%) had pneumonia, 9 patients (5.23%) had bacteremia, one patient (0.58%) had mediastinitis, one (0.58%) had harvest surgical site infection, one (0.58%) had urinary tract infection, and another one patient (0.58%) had other major infection. The mortality rate was 25% among the patients with infection and 3.48% among all patients who underwent cardiac surgery compared with 5.4% of patients who did not develop early postoperative infection after cardiac surgery. Culture results demonstrated equal frequencies of gram-positive cocci and gram-negative bacteria. A backward stepwise multivariable logistic regression model analysis identified diabetes mellitus (OR 5.92, CI 1.56 to 22.42, p = 0.009), duration of mechanical ventilation (OR 1.30, CI 1.005 to 1.69, p = 0.046), development of severe complications in the CICU (OR 18.66, CI 3.36 to 103.61, p = 0.001) and re-admission to the CVICU (OR 8.59, CI 2.02 to 36.45, p = 0.004) as independent risk factors associated with development of nosocomial infection after cardiac surgery.</p> <p>Conclusions</p> <p>We concluded that diabetes mellitus, the duration of mechanical ventilation, the presence of complications irrelevant to the infection during CVICU stay and CVICU re-admission are independent risk factors for the development of postoperative infection in cardiac surgery patients.</p
    corecore