180 research outputs found
Recommended from our members
Online monitoring of dispersion functions and transfer matrices at the SLC
The symmetries of the chromatic correction sections in the SLC Final Focus System allow a high-resolution determination of the pulse-to-pulse energy fluctuations by exploiting the information from beam position monitors (BPMs) in regions of large dispersion. By correlating this signal with other BPMs, one can infer the dispersion function as well as spatial components of transfer matrices anywhere in the arcs and the Final Focus System without interrupting normal machine operation. We present results from data recorded during either periods of stable operation or periods when the linac energy was intentionally varied. 6 refs., 7 figs
Recommended from our members
Bunch compression for the TLC: Preliminary design
A preliminary design of a TLC bunch compressor as a two-stage device is described. The main parameters of the compressor, as well as results of some simulations, are presented. They show that the ideal system (no imperfections) does the job of transmitting transverse emittances without distortions (at least up to the second-order terms) producing at the same time the desired bunch length of 50 m. 9 refs., 6 figs., 4 tabs
Recommended from our members
Recent Improvements in the SLC Positron System Performance
The positron system is very specific to the SLC in that the positrons are accelerated in the same linac as the electrons that produce them and the electrons with which they collide. Some of the difficulties in tuning this system to peak performance are thus unlikely to be encountered in future linear colliders, but many of the lessons learned in beam matching are useful for future machines. The design and commissioning of this system has been previously reported so we only briefly describe the major subsystems before detailing the tuning and diagnostics involved in optimizing the performance of the overall system
Recommended from our members
Recent Improvements in the SLC Positron System Performance
The positron system is very specific to the SLC in that the positrons are accelerated in the same linac as the electrons that produce them and the electrons with which they collide. Some of the difficulties in tuning this system to peak performance are thus unlikely to be encountered in future linear colliders, but many of the lessons learned in beam matching are useful for future machines. The design and commissioning of this system has been previously reported so we only briefly describe the major subsystems before detailing the tuning and diagnostics involved in optimizing the performance of the overall system
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410
has been developed by Hamamatsu for dark matter direct detection experiments
using liquid xenon as the target material. We present the results from the
joint effort between the XENON collaboration and the Hamamatsu company to
produce a highly radio-pure photosensor (version R11410-21) for the XENON1T
dark matter experiment. After introducing the photosensor and its components,
we show the methods and results of the radioactive contamination measurements
of the individual materials employed in the photomultiplier production. We then
discuss the adopted strategies to reduce the radioactivity of the various PMT
versions. Finally, we detail the results from screening 216 tubes with
ultra-low background germanium detectors, as well as their implications for the
expected electronic and nuclear recoil background of the XENON1T experiment.Comment: 10 pages, 5 figure
Search for Event Rate Modulation in XENON100 Electronic Recoil Data
We have searched for periodic variations of the electronic recoil event rate
in the (2-6) keV energy range recorded between February 2011 and March 2012
with the XENON100 detector, adding up to 224.6 live days in total. Following a
detailed study to establish the stability of the detector and its background
contributions during this run, we performed an un-binned profile likelihood
analysis to identify any periodicity up to 500 days. We find a global
significance of less than 1 sigma for all periods suggesting no statistically
significant modulation in the data. While the local significance for an annual
modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and
the phase of the modulation disfavor a dark matter interpretation. The
DAMA/LIBRA annual modulation interpreted as a dark matter signature with
axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.Comment: 6 pages, 4 figure
Search for Two-Neutrino Double Electron Capture of Xe with XENON100
Two-neutrino double electron capture is a rare nuclear decay where two
electrons are simultaneously captured from the atomic shell. For Xe
this process has not yet been observed and its detection would provide a new
reference for nuclear matrix element calculations. We have conducted a search
for two-neutrino double electron capture from the K-shell of Xe using
7636 kgd of data from the XENON100 dark matter detector. Using a
Bayesian analysis we observed no significant excess above background, leading
to a lower 90 % credibility limit on the half-life
yr. We also evaluated the sensitivity of the XENON1T experiment, which is
currently being commissioned, and find a sensitivity of
yr after an exposure of 2 tyr.Comment: 6 pages, 4 figure
Removing krypton from xenon by cryogenic distillation to the ppq level
The XENON1T experiment aims for the direct detection of dark matter in a
cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired
sensitivity, the background induced by radioactive decays inside the detector
has to be sufficiently low. One major contributor is the -emitter
Kr which is an intrinsic contamination of the xenon. For the XENON1T
experiment a concentration of natural krypton in xenon Kr/Xe < 200
ppq (parts per quadrillion, 1 ppq = 10 mol/mol) is required. In this
work, the design of a novel cryogenic distillation column using the common
McCabe-Thiele approach is described. The system demonstrated a krypton
reduction factor of 6.410 with thermodynamic stability at process
speeds above 3 kg/h. The resulting concentration of Kr/Xe < 26 ppq
is the lowest ever achieved, almost one order of magnitude below the
requirements for XENON1T and even sufficient for future dark matter experiments
using liquid xenon, such as XENONnT and DARWIN
Radio Astronomy
Contains table of contents for Section 4 and reports on nine research projects.National Science Foundation Grant AST 88-19848National Science Foundation Grant AST 90-22501Alfred P. Sloan FellowshipNational Science Foundation Presidential Young Investigator AwardNational Aeronautics and Space Administration Grant NAGW-2310David and Lucile Packard FellowshipSM Systems and Research CorporationNational Aeronautics and Space Administration/Goddard Space Flight Center Contract NAS 5-30791National Aeronautics and Space Administration/Goddard Space Flight Center Grant NAG5-10Leaders for Manufacturing Progra
Non-stationary covariance function modelling in 2D least-squares collocation
Standard least-squares collocation (LSC) assumes 2D stationarity and 3D isotropy, and relies on a covariance function to account for spatial dependence in the ob-served data. However, the assumption that the spatial dependence is constant through-out the region of interest may sometimes be violated. Assuming a stationary covariance structure can result in over-smoothing of, e.g., the gravity field in mountains and under-smoothing in great plains. We introduce the kernel convolution method from spatial statistics for non-stationary covariance structures, and demonstrate its advantage fordealing with non-stationarity in geodetic data. We then compared stationary and non-stationary covariance functions in 2D LSC to the empirical example of gravity anomaly interpolation near the Darling Fault, Western Australia, where the field is anisotropic and non-stationary. The results with non-stationary covariance functions are better than standard LSC in terms of formal errors and cross-validation against data not used in the interpolation, demonstrating that the use of non-stationary covariance functions can improve upon standard (stationary) LSC
- …