1,138 research outputs found
Neoadjuvant pazopanib and molecular analysis of tissue response in renal cell carcinoma
BACKGROUND. Surgery remains the frontline therapy for patients with localized clear cell renal cell carcinoma (ccRCC); however, 20%â40% recur. Angiogenesis inhibitors have improved survival in metastatic patients and may result in responses in the neoadjuvant setting. The impact of these agents on the tumor genetic heterogeneity or the immune milieu is largely unknown. This phase II study was designed to evaluate safety, response, and effect on tumor tissue of neoadjuvant pazopanib. METHODS. ccRCC patients with localized disease received pazopanib (800 mg daily; median 8 weeks), followed by nephrectomy. Five tumors were examined for mutations by whole exome sequencing from samples collected before therapy and at nephrectomy. These samples underwent RNA sequencing; 17 samples were available for posttreatment assessment. RESULTS. Twenty-one patients were enrolled. The overall response rate was 8 of 21 (38%). No patients with progressive disease. At 1-year, response-free survival and overall survival was 83% and 89%, respectively. The most frequent grade 3 toxicity was hypertension (33%, 7 of 21). Sequencing revealed strong concordance between pre- and posttreatment samples within individual tumors, suggesting tumors harbor stable core profiles. However, a reduction in private mutations followed treatment, suggesting a selective process favoring enrichment of driver mutations. CONCLUSION. Neoadjuvant pazopanib is safe and active in ccRCC. Future genomic analyses may enable the segregation of driver and passenger mutations. Furthermore, tumor infiltrating immune cells persist during therapy, suggesting that pazopanib can be combined with immune checkpoint inhibitors without dampening the immune response. FUNDING. Support was provided by Novartis and GlaxoSmithKline as part of an investigator-initiated study
Fluorescent carbon dioxide indicators
Over the last decade, fluorescence has become the dominant tool in biotechnology and medical imaging. These exciting advances have been underpinned by the advances in time-resolved techniques and instrumentation, probe design, chemical / biochemical sensing, coupled with our furthered knowledge in biology. Complementary volumes 9 and 10, Advanced Concepts of Fluorescence Sensing: Small Molecule Sensing and Advanced Concepts of Fluorescence Sensing: Macromolecular Sensing, aim to summarize the current state of the art in fluorescent sensing. For this reason, Drs. Geddes and Lakowicz have invited chapters, encompassing a broad range of fluorescence sensing techniques. Some chapters deal with small molecule sensors, such as for anions, cations, and CO2, while others summarize recent advances in protein-based and macromolecular sensors. The Editors have, however, not included DNA or RNA based sensing in this volume, as this were reviewed in Volume 7 and is to be the subject of a more detailed volume in the near future
Eureka and beyond: mining's impact on African urbanisation
This collection brings separate literatures on mining and urbanisation together at a time when both artisanal and large-scale mining are expanding in many African economies. While much has been written about contestation over land and mineral rights, the impact of mining on settlement, notably its catalytic and fluctuating effects on migration and urban growth, has been largely ignored. African nation-statesâ urbanisation trends have shown considerable variation over the past half century. The current surge in ânewâ mining countries and the slow-down in âoldâ mining countries are generating some remarkable settlement patterns and welfare outcomes. Presently, the African continent is a laboratory of national mining experiences. This special issue on African mining and urbanisation encompasses a wide cross-section of country case studies: beginning with the historical experiences of mining in Southern Africa (South Africa, Zambia, Zimbabwe), followed by more recent mineralizing trends in comparatively new mineral-producing countries (Tanzania) and an established West African gold producer (Ghana), before turning to the influence of conflict minerals (Angola, the Democratic Republic of Congo and Sierra Leone)
A New Faint Milky Way Satellite Discovered in the Pan-STARRS1 3Ï Survey
We present the discovery of a faint Milky Way satellite, Laevens 2/Triangulum II, found in the Panoramic Survey Telescope And Rapid Response System (Pan-STARRS 1) 3 pi imaging data and confirmed with follow-up wide-field photometry from the Large Binocular Cameras. The stellar system, with an absolute magnitude of M_V=-1.8 +/-0.5, a heliocentric distance of 30 +2/-2 kpc, and a half-mass radius of 34 +9/-8 pc, shows remarkable similarity to faint, nearby, small satellites such as Willman 1, Segue 1, Segue 2, and Bo\"otes II. The discovery of Laevens 2/Triangulum II further populates the region of parameter space for which the boundary between dwarf galaxies and globular clusters becomes tenuous. Follow-up spectroscopy will ultimately determine the nature of this new satellite, whose spatial location hints at a possible connection with the complex Triangulum-Andromeda stellar structures
Toward an internally consistent astronomical distance scale
Accurate astronomical distance determination is crucial for all fields in
astrophysics, from Galactic to cosmological scales. Despite, or perhaps because
of, significant efforts to determine accurate distances, using a wide range of
methods, tracers, and techniques, an internally consistent astronomical
distance framework has not yet been established. We review current efforts to
homogenize the Local Group's distance framework, with particular emphasis on
the potential of RR Lyrae stars as distance indicators, and attempt to extend
this in an internally consistent manner to cosmological distances. Calibration
based on Type Ia supernovae and distance determinations based on gravitational
lensing represent particularly promising approaches. We provide a positive
outlook to improvements to the status quo expected from future surveys,
missions, and facilities. Astronomical distance determination has clearly
reached maturity and near-consistency.Comment: Review article, 59 pages (4 figures); Space Science Reviews, in press
(chapter 8 of a special collection resulting from the May 2016 ISSI-BJ
workshop on Astronomical Distance Determination in the Space Age
SARS-CoV Antibody Prevalence in All Hong Kong Patient Contacts
A total of 1,068 asymptomatic close contacts of patients with severe acute respiratory (SARS) from the 2003 epidemic in Hong Kong were serologically tested, and 2 (0.19%) were positive for SARS coronavirus immunoglobulin G antibody. SARS rarely manifests as a subclinical infection, and at present, wild animal species are the only important natural reservoirs of the virus
Updated meta-analysis of randomized controlled trials comparing conventional excisional haemorrhoidectomy with LigaSure for haemorrhoids
Background:\ud
To compare the surgical outcome of haemorrhoidectomy performed using LigaSure bipolar diathermy with conventional haemorrhoidectomy.\ud
\ud
Methods:\ud
Only randomized and alternate allocated studies were included from the major electronic databases using the search terms "ligasure" and "haemorrhoids" Duration of operation, blood loss during operation, postoperative pain score, wound healing, in-hospital stay, time to return to normal activities and complications were assessed.\ud
\ud
Results:\ud
The 11 trials contained a total of 1,046 patients; the largest study was based on 273 patients and two earlier studies were based on 34 patients. No significant gender mismatch between the groups was reported in any of the studies. The patientsâ ages were similar between groups in the studies, as was disease severity. All 11 studies reported a shorter duration of the operation when using LigaSure compared to the conventional technique (p<0.001). The postoperative pain score (p=0.001) and blood loss during operation (p=0.001) were significantly reduced. After LigaSure haemorrhoidectomy wound healing (p=0.004) and the return to normal activities (p=0.001) were significantly faster than after conventional haemorrhoidectomy. However, the overall incidence of complications reported was not significantly different (p=0.056).\ud
\ud
Conclusions:\ud
LigaSure is an effective instrument for haemorrhoidectomy which results in less blood loss, quicker wound healing and earlier return to work.\u
An Integrated TCGA Pan-Cancer Clinical Data Resource to Drive High-Quality Survival Outcome Analytics
For a decade, The Cancer Genome Atlas (TCGA) program collected clinicopathologic annotation data along with multi-platform molecular profiles of more than 11,000 human tumors across 33 different cancer types. TCGA clinical data contain key features representing the democratized nature of the data collection process. To ensure proper use of this large clinical dataset associated with genomic features, we developed a standardized dataset named the TCGA Pan-Cancer Clinical Data Resource (TCGA-CDR), which includes four major clinical outcome endpoints. In addition to detailing major challenges and statistical limitations encountered during the effort of integrating the acquired clinical data, we present a summary that includes endpoint usage recommendations for each cancer type. These TCGA-CDR findings appear to be consistent with cancer genomics studies independent of the TCGA effort and provide opportunities for investigating cancer biology using clinical correlates at an unprecedented scale. Analysis of clinicopathologic annotations for over 11,000 cancer patients in the TCGA program leads to the generation of TCGA Clinical Data Resource, which provides recommendations of clinical outcome endpoint usage for 33 cancer types
Measurement of the Atmospheric Muon Spectrum from 20 to 3000 GeV
The absolute muon flux between 20 GeV and 3000 GeV is measured with the L3
magnetic muon spectrometer for zenith angles ranging from 0 degree to 58
degree. Due to the large exposure of about 150 m2 sr d, and the excellent
momentum resolution of the L3 muon chambers, a precision of 2.3 % at 150 GeV in
the vertical direction is achieved.
The ratio of positive to negative muons is studied between 20 GeV and 500
GeV, and the average vertical muon charge ratio is found to be 1.285 +- 0.003
(stat.) +- 0.019 (syst.).Comment: Total 32 pages, 9Figure
Measurement of Mass and Width of the W Boson at LEP
We report on measurements of the mass and total decay width of the W boson
with the L3 detector at LEP. W-pair events produced in
interactions between 161 GeV and 183 GeV centre-of-mass energy are selected in
a data sample corresponding to a total luminosity of 76.7 pb. Combining
all final states in W-pair production, the mass and total decay width of the W
boson are determined to be GeV and
GeV, respectively
- âŠ