703 research outputs found

    Ensuring Readability and Data-fidelity using Head-modifier Templates in Deep Type Description Generation

    Full text link
    A type description is a succinct noun compound which helps human and machines to quickly grasp the informative and distinctive information of an entity. Entities in most knowledge graphs (KGs) still lack such descriptions, thus calling for automatic methods to supplement such information. However, existing generative methods either overlook the grammatical structure or make factual mistakes in generated texts. To solve these problems, we propose a head-modifier template-based method to ensure the readability and data fidelity of generated type descriptions. We also propose a new dataset and two automatic metrics for this task. Experiments show that our method improves substantially compared with baselines and achieves state-of-the-art performance on both datasets.Comment: ACL 201

    Content adaptive sparse illumination for Fourier ptychography

    Full text link
    Fourier Ptychography (FP) is a recently proposed technique for large field of view and high resolution imaging. Specifically, FP captures a set of low resolution images under angularly varying illuminations and stitches them together in Fourier domain. One of FP's main disadvantages is its long capturing process due to the requisite large number of incident illumination angles. In this letter, utilizing the sparsity of natural images in Fourier domain, we propose a highly efficient method termed as AFP, which applies content adaptive sparse illumination for Fourier ptychography by capturing the most informative parts of the scene's spatial spectrum. We validate the effectiveness and efficiency of the reported framework with both simulations and real experiments. Results show that the proposed AFP could shorten the acquisition time of conventional FP by around 30%-60%

    Fourier ptychographic reconstruction using Poisson maximum likelihood and truncated Wirtinger gradient

    Get PDF
    Fourier ptychographic microscopy (FPM) is a novel computational coherent imaging technique for high space-bandwidth product imaging. Mathematically, Fourier ptychographic (FP) reconstruction can be implemented as a phase retrieval optimization process, in which we only obtain low resolution intensity images corresponding to the sub-bands of the sample's high resolution (HR) spatial spectrum, and aim to retrieve the complex HR spectrum. In real setups, the measurements always suffer from various degenerations such as Gaussian noise, Poisson noise, speckle noise and pupil location error, which would largely degrade the reconstruction. To efficiently address these degenerations, we propose a novel FP reconstruction method under a gradient descent optimization framework in this paper. The technique utilizes Poisson maximum likelihood for better signal modeling, and truncated Wirtinger gradient for error removal. Results on both simulated data and real data captured using our laser FPM setup show that the proposed method outperforms other state-of-the-art algorithms. Also, we have released our source code for non-commercial use

    Motion-corrected Fourier ptychography

    Get PDF
    Fourier ptychography (FP) is a recently proposed computational imaging technique for high space-bandwidth product imaging. In real setups such as endoscope and transmission electron microscope, the common sample motion largely degrades the FP reconstruction and limits its practicability. In this paper, we propose a novel FP reconstruction method to efficiently correct for unknown sample motion. Specifically, we adaptively update the sample's Fourier spectrum from low spatial-frequency regions towards high spatial-frequency ones, with an additional motion recovery and phase-offset compensation procedure for each sub-spectrum. Benefiting from the phase retrieval redundancy theory, the required large overlap between adjacent sub-spectra offers an accurate guide for successful motion recovery. Experimental results on both simulated data and real captured data show that the proposed method can correct for unknown sample motion with its standard deviation being up to 10% of the field-of-view scale. We have released our source code for non-commercial use, and it may find wide applications in related FP platforms such as endoscopy and transmission electron microscopy

    Demonstration and Operation of Quantum Harmonic Oscillators in AlGaAs/GaAs Heterostructure

    Full text link
    The quantum harmonic oscillator (QHO), one of the most important and ubiquitous model systems in quantum mechanics, features equally spaced energy levels or eigenstates. Here we report on the design, demonstration and operation of nearly perfect QHOs in AlGaAs/GaAs heterostructure. On the basis of model calculations, we demonstrate that, when a substitutional Si donor substitutes the Ga/Al lattice site close to AlGaAs/GaAs heterointerface, a hydrogenic Si QHO, characterized by a restoring Coulomb force producing square law harmonic potential, is formed. This gives rise to QHO states with energy spacing of ~8-9 meV. We experimentally confirm this proposal by utilizing Stark effect and measuring QHO states using an aluminum single-electron transistor (SET). A sharp and fast oscillation with period of ~7-8 mV appears in addition to the regular Coulomb blockade (CB) oscillation with much larger period, for positive gate biases above 0.5 V. The observation of fast oscillation and its behavior is qualitatively consistent with our theoretical result, manifesting the harmonic motion of electrons from the QHO. Our results might establish a general principle to design, construct and manipulate QHOs in semiconductor heterostructures.Comment: 17 pages, 4 figure
    • …
    corecore