    Placido disk-based topography versus high-resolution rotating scheimpflug camera for corneal power measurements in keratoconic and post-lasik eyes: Reliability and agreement

    Get PDF
    AIM: To compare the repeatability/reproducibility of measurement by high-resolution Placido disk-based topography with that of a high-resolution rotating Scheimpflug camera and assess the agreement between the two instruments in measuring corneal power in eyes with keratoconus and post-laser in situ keratomileusis (LASIK). METHODS: One eye each of 36 keratoconic patients and 20 subjects who had undergone LASIK was included in this prospective observational study. Two independent examiners worked in a random order to take three measurements of each eye with both instruments. Four parameters were measured on the anterior cornea: steep keratometry (Ks), flat keratometry (Kf), mean keratometry (Km), and astigmatism (Ks-Kf). Intra-examiner repeatability and inter-examiner reproducibility were evaluated by calculating the within-subject standard deviation (Sw) the coefficient of repeatability (R), the coefficient of variation (CoV), and the intraclass correlation coefficient (ICC). Agreement between instruments was tested with the Bland-Altman method by calculating the 95% limits of agreement (95% LoA). RESULTS: In keratoconic eyes, the intra-examiner and inter-examiner ICC were >0.95. As compared with measurement by high-resolution Placido disk-based topography, the intra-examiner R of the high-resolution rotating Scheimpflug camera was lower for Kf (0.32 vs 0.88), Ks (0.61 vs 0.88), and Km (0.32 vs 0.84) but higher for Ks-Kf (0.70 vs 0.57). Inter-examiner R values were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The 95% LoA were -1.28 to +0.55 for Kf, -1.36 to +0.99 for Ks, -1.08 to +0.50 for Km, and -1.11 to +1.48 for Ks-Kf. In the post-LASIK eyes, the intra-examiner and inter-examiner ICC were >0.87 for all parameters. The intra-examiner and inter-examiner R were lower for all parameters measured using the high-resolution rotating Scheimpflug camera. The intra-examiner R was 0.17 vs 0.88 for Kf, 0.21 vs 0.88 for Ks, 0.17 vs 0.86 for Km, and 0.28 vs 0.33 for Ks-Kf. The inter-examiner R was 0.09 vs 0.64 for Kf, 0.15 vs 0.56 for Ks, 0.09 vs 0.59 for Km, and 0.18 vs 0.23 for Ks-Kf. The 95% LoA were -0.54 to +0.58 for Kf, -0.51 to +0.53 for Ks and Km, and -0.28 to +0.27 for Ks-Kf. CONCLUSION: As compared with Placido disk-based topography, the high-resolution rotating Scheimpflug camera provides more repeatable and reproducible measurements of Ks, Kf and Ks in keratoconic and post-LASIK eyes. Agreement between instruments is fair in keratoconus and very good in post-LASIK eyes

    Microperimetric Assessment after Epiretinal Membrane Surgery: 4-Year Follow-Up

    Get PDF
    Purpose. To investigate retinal function using microperimetry in patients affected by idiopathic epiretinal membrane (iERM) and cataract who underwent combined surgery: 4-year follow-up. Design. Prospective, interventional case series. Methods. 30 eyes of 30 consecutive patients with iERM and age-related cataract underwent 25-gauge vitrectomy and cataract surgery. At baseline, 90 and 180 days, and 1 and 4 years, we examined retinal mean sensitivity (MS), retinal mean defect (MD), fixation stability, and frequency of microscotomas using MP1 microperimetry. Best-corrected visual acuity (BCVA) and central retinal thickness (CRT) using a spectral domain optical coherence tomography (SD-OCT) were also performed. Results. All patients completed 1-year follow-up, while 23 patients reached last follow-up. Baseline MS and MD (10.48 ± 4.17 and −9.18 ± 4.40 dB) significantly changed at one year (12.33 ± 3.66 and −7.49 ± 3.31 dB, p<0.01), at four years (14.18 ± 3.46 and −4.66 ± 2.85, p<0.01), and between one and four years (p<0.01) after surgery. Compared to baseline, CRT and BCVA significantly changed at one year and remained stable at four years. No variations were observed in fixation stability and frequency of microscotomas compared to baseline. Conclusions. Long-term follow-up using microperimetry seems useful to evaluate patients after iERM surgery: retinal sensitivity changes even when BCVA and CRT remain stable

    The Effect of Autologous Platelet Lysate Eye Drops: An In Vivo Confocal Microscopy Study

    Get PDF
    Purpose. To determine the effectiveness of autologous platelet lysate (APL) eye drops in patients with primary Sjögren syndrome (SS) dry eye, refractory to standard therapy, in comparison with patients treated with artificial tears. We focused on the effect of APL on cornea morphology with the in vivo confocal microscopy (IVCM). Methods. Patients were assigned to two groups: group A used autologous platelet lysate QID, and group B used preservative-free artificial tears QID, for 90 days. Ophthalmological assessments included ocular surface disease index (OSDI), best corrected visual acuity (BCVA), Schirmer test, fluorescein score, and breakup time (BUT). A subgroup of patients in group A underwent IVCM: corneal basal epithelium, subbasal nerves, Langerhans cells, anterior stroma activated keratocytes, and reflectivity were evaluated. Results. 60 eyes of 30 patients were enrolled; in group A (n=20 patients) mean OSDI, fluorescein score, and BUT showed significant improvement compared with group B (n=10 patients). The IVCM showed a significant increase in basal epithelium cells density and subbasal nerve plexus density and number and a decrease in Langerhans cells density (p<0.05). Conclusion. APL was found effective in the treatment of SS dry eye. IVCM seems to be a useful tool to visualize cornea morphologic modifications

    Health-related quality of life in patients with primary open-angle glaucoma. An Italian multicentre observational study

    Get PDF
    Purpose: As a progressive condition, glaucoma may impair health-related quality of life (HRQoL), due to vision loss and other factors. This study evaluated HRQoL in a cohort of patients treated for primary open-angle glaucoma (POAG) and assessed its association with clinical features. Methods: This was an Italian, multicentre, cross-sectional, observational study with the subgroup of newly diagnosed patients with POAG prospectively followed up for one year. Patients with previous or new diagnosis (or strong clinical suspicion) of POAG aged >18 years were considered eligible. Information was collected on demographic characteristics, medical history, clinical presentation and POAG treatments. HRQoL was measured using the 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25) and Glaucoma Symptom Scale (GSS). Subscale and total scores were obtained and a Pearson correlation coefficient between instruments’ scores calculated. Results: A total of 3227 patients were enrolled from 2012 to 2013 and 3169 were analysed. Mean age was 66.9 years. A total of 93.8% had a previous diagnosis (median duration: 8.0 years). Median values for mean deviation and pattern standard deviation were 3.9 and 3.6 dB, respectively. Mean scores on most subscales of the NEI-VFQ-25 exceeded 75.0 and mean GSS subscale scores ranged between 70.8 and 79.7 (with a total mean score of 74.8). HRQoL scores on both scales were significantly inversely associated with POAG severity. Conclusion: In this large sample of Italians treated for POAG, disease severity was limited and HRQoL scores were high. QoL decreased with advancing disease severity. These findings confirm the role of vision loss in impairing QoL in POAG, underlying the importance of timely detection and appropriate treatment

    Medical costs of glaucoma and ocular hypertension in italian referral centres:a prospective study.