37 research outputs found

    Pattern formation in electrically coupled pacemaker cells

    Get PDF
    CAUL read and publish agreement 2022Publishe

    Rhythmic potassium transport regulates the circadian clock in human red blood cells.

    Get PDF
    Circadian rhythms organize many aspects of cell biology and physiology to a daily temporal program that depends on clock gene expression cycles in most mammalian cell types. However, circadian rhythms are also observed in isolated mammalian red blood cells (RBCs), which lack nuclei, suggesting the existence of post-translational cellular clock mechanisms in these cells. Here we show using electrophysiological and pharmacological approaches that human RBCs display circadian regulation of membrane conductance and cytoplasmic conductivity that depends on the cycling of cytoplasmic K+ levels. Using pharmacological intervention and ion replacement, we show that inhibition of K+ transport abolishes RBC electrophysiological rhythms. Our results suggest that in the absence of conventional transcription cycles, RBCs maintain a circadian rhythm in membrane electrophysiology through dynamic regulation of K+ transport

    Biosensors

    No full text
    At least one-third of the authors are expected to be from Europe and Japan. Since this encyclopedia is the first book in this emerging and potentially large field, the market is expected to be large and steady

    Biosensors

    No full text
    At least one-third of the authors are expected to be from Europe and Japan. Since this encyclopedia is the first book in this emerging and potentially large field, the market is expected to be large and steady

    Dielectrophoretic sample preparation for environmental monitoring of microorganisms: Soil particle removal

    Get PDF
    Detection of pathogens from environmental samples is often hampered by sensors interacting with environmental particles such as soot, pollen, or environmental dust such as soil or clay. These particles may be of similar size to the target bacterium, preventing removal by filtration, but may non-specifically bind to sensor surfaces, fouling them and causing artefactual results. In this paper, we report the selective manipulation of soil particles using an AC electrokinetic microfluidic system. Four heterogeneous soil samples (smectic clay, kaolinitic clay, peaty loam, and sandy loam) were characterised using dielectrophoresis to identify the electrical difference to a target organism. A flow-cell device was then constructed to evaluate dielectrophoretic separation of bacteria and clay in a continous flow through mode. The average separation efficiency of the system across all soil types was found to be 68.7% with a maximal separation efficiency for kaolinitic clay at 87.6%. This represents the first attempt to separate soil particles from bacteria using dielectrophoresis and indicate that the technique shows significant promise; with appropriate system optimisation, we believe that this preliminary study represents an opportunity to develop a simple yet highly effective sample processing system

    A bio-analytical system for rapid cellular electrophysiological assays.

    No full text
    In this paper, the use of non-uniform ac electric fields on biological cells for bioanalysis, through multiple, independently configurable channels is presented. The programmable system has been used to obtain the dielectrophoretic spectra of cells in near real time, within 90 seconds. This is a significant improvement on existing dielectrophoretic techniques as simultaneous parallel measurement of the dielectrophoretic forces at different frequencies has potential of revealing subtle changes to the electrophysiology of cells, as they occur. The results show that with continuous on-chip monitoring, cells exposed to a chemical agent that induces apoptosis begin to exhibit a spectrum that differs from untreated cells, as indicated from shifts in the observed crossover frequency values

    A bio-analytical system for rapid cellular electrophysiological assays.

    No full text
    In this paper, the use of non-uniform ac electric fields on biological cells for bioanalysis, through multiple, independently configurable channels is presented. The programmable system has been used to obtain the dielectrophoretic spectra of cells in near real time, within 90 seconds. This is a significant improvement on existing dielectrophoretic techniques as simultaneous parallel measurement of the dielectrophoretic forces at different frequencies has potential of revealing subtle changes to the electrophysiology of cells, as they occur. The results show that with continuous on-chip monitoring, cells exposed to a chemical agent that induces apoptosis begin to exhibit a spectrum that differs from untreated cells, as indicated from shifts in the observed crossover frequency values

    A bio-analytical system for rapid cellular electrophysiological assays.

    No full text
    In this paper, the use of non-uniform ac electric fields on biological cells for bioanalysis, through multiple, independently configurable channels is presented. The programmable system has been used to obtain the dielectrophoretic spectra of cells in near real time, within 90 seconds. This is a significant improvement on existing dielectrophoretic techniques as simultaneous parallel measurement of the dielectrophoretic forces at different frequencies has potential of revealing subtle changes to the electrophysiology of cells, as they occur. The results show that with continuous on-chip monitoring, cells exposed to a chemical agent that induces apoptosis begin to exhibit a spectrum that differs from untreated cells, as indicated from shifts in the observed crossover frequency values
    corecore