13 research outputs found
Rhythm monitoring, success definition, recurrence, and anticoagulation after atrial fibrillation ablation: results from an EHRA survey
Atrial fibrillation (AF) is a major challenge for the healthcare field. Pulmonary vein isolation is the most effective treatment for the maintenance of sinus rhythm. However, clinical endpoints for the procedure vary significantly among studies. There is no consensus on the definition of recurrence and no clear roadmap on how to deal with recurrences after a failed ablation. The purpose of this study was to perform a survey in order to show how clinicians currently approach this knowledge gap. An online survey, supported by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee, was conducted between 1 April 2022 and 8 May 2022. An anonymous questionnaire was disseminated via social media and EHRA newsletters, for clinicians to complete. This consisted of 18 multiple-choice questions regarding rhythm monitoring, definitions of a successful ablation, clinical practices after a failed AF ablation, and the continuance of anticoagulation. A total of 107 replies were collected across Europe. Most respondents (82%) perform routine monitoring for AF recurrences after ablation, with 51% of them preferring a long-term monitoring strategy. Cost was reported to have an impact on the choice of monitoring strategy. Self-screening was recommended by most (71%) of the respondents. The combination of absence of symptoms and recorded AF was the definition of success for most (83%) of the respondents. Cessation of anticoagulation after ablation was an option mostly for patients with paroxysmal AF and a low CHA2DS2-VASc score. The majority of physicians perform routine monitoring after AF ablation. For most physicians, the combination of the absence of symptoms and electrocardiographic endpoints defines a successful result after AF ablation
Antithrombotic treatment management in low stroke risk patients undergoing cardioversion of atrial fibrillation <48 h duration: results of an EHRA survey
Data supporting the safety of cardioversion (CV) of atrial fibrillation (AF) without anticoagulation in patients with AF duration <48âh are scarce. Observational studies suggest that the risk of stroke in these patients is very low when the definite duration of the AF episode is of <48âh and the clinical risk profile as estimated through the CHA2DS2VASc score is low (a score of 0 for men and 1 for women). As the recent 2020 European Society of Cardiology (ESC) guidelines indication for this clinical scenario is based mainly on consensus, we sent out a survey to assess the current clinical practice on anticoagulation prior to and post-CV in patients with AF <24-48âh duration and low stroke risk across centres in Europe. Of the 136 respondents, half were affiliated to university hospitals (68/136; 50%). Non-university hospitals (50/136; 36%) and private hospitals (2/136; 1.4%) accounted over a third of respondents. The main findings of our survey were (i) heterogeneity in the anticoagulation management both before and post-CV in low stroke-risk patients with AF <48âh, (ii) higher utilization of periprocedural low-molecular-weight heparin than of non-vitamin K antagonist oral anticoagulant, (iii) higher utilization of pre-CV transoesophageal echocardiography for electrical CV than for pharmacological CV regardless of the duration of AF, (iv) high adherence to a 4-week post-CV oral anticoagulant (OAC) therapy, mainly for electrical CV, and finally, (v) perceived higher acceptance of lack of post-CV OAC therapy in patients with <24âh than 24-48âh episode duration. The results obtained in this survey highlight the need for more research providing definitive clarification on the safety of CV without anticoagulation in patients with short duration AF
General practitionersâ perceptions on opportunistic single-time point screening for atrial fibrillation: A European quantitative survey
Background: There is no clear guidance on how to implement opportunistic atrial fibrillation (AF) screening in daily clinical practice. Objectives: This study evaluated the perception of general practitioners (GPs) about value and practicalities of implementing screening for AF, focusing on opportunistic single-time point screening with a single-lead electrocardiogram (ECG) device. Methods: A descriptive cross-sectional study was conducted with a survey developed to assess overall perception concerning AF screening, feasibility of opportunistic single-lead ECG screening and implementation requirements and barriers. Results: A total of 659 responses were collected (36.1% Eastern, 33.4% Western, 12.1% Southern, 10.0% Northern Europe, 8.3% United Kingdom & Ireland). The perceived need for standardized AF screening was rated as 82.7 on a scale from 0 to 100. The vast majority (88.0%) indicated no AF screening program is established in their region. Three out of four GPs (72.1%, lowest in Eastern and Southern Europe) were equipped with a 12-lead ECG, while a single-lead ECG was less common (10.8%, highest in United Kingdom & Ireland). Three in five GPs (59.3%) feel confident ruling out AF on a single-lead ECG strip. Assistance through more education (28.7%) and a tele-healthcare service offering advice on ambiguous tracings (25.2%) would be helpful. Preferred strategies to overcome barriers like insufficient (qualified) staff, included integrating AF screening with other healthcare programs (24.9%) and algorithms to identify patients most suitable for AF screening (24.3%). Conclusion: GPs perceive a strong need for a standardized AF screening approach. Additional resources may be required to have it widely adopted into clinical practice
Antithrombotic therapy for stroke prevention in patients with atrial fibrillation who survive an intracerebral haemorrhage: results of an EHRA survey
Abstract The aim of this survey is to provide a snapshot of current practice regarding antithrombotic therapy (ATT) in patients with atrial fibrillation (AF) comorbid with intracerebral haemorrhage (ICH). An online survey was distributed to members of the European Heart Rhythm Association. A total of 163 clinicians responded, mostly cardiologists or electrophysiologists (87.7%), predominantly working in University hospitals (61.3%). Most respondents (47.2%) had seen one to five patients with AF comorbid with ICH in the last 12 months. Among patients sustaining an ICH on oral anticoagulation (OAC), 84.3% respondents would consider some form of ATT post-ICH, with 73.2% preferring to switch from a vitamin-K antagonist (VKA) to a non-VKA oral anticoagulant (NOAC) and 37.2% preferring to switch from one NOAC to another. Most (36.6%) would restart OAC &gt;30âdays post-ICH. Among patients considered unable to take OAC, left atrial appendage occlusion procedure was the therapy of choice in 73.3% respondents. When deciding on ATT, respondents considered patientâs CHA2DS2-VASc score, ICH type, demographics, risk factors, and patient adherence. The main reason for not restarting or commencing ATT was concern about recurrent ICH (80.8%). National or international clinical guidelines would be advantageous to support decision-making (84.3%). Other helpful resources reported were multidisciplinary team involvement (46.9%) and patient education (82%). In summary, most survey respondents would prescribe OAC therapy for patients with AF who have sustained an ICH on OAC and would restart OAC &gt;30âdays post-ICH. The risk of recurrent ICH was the main reason for not prescribing any ATT post-ICH.</jats:p
Contemporary management of patients with syncope in clinical practice: an EHRA physician-based survey
Syncope is a heterogeneous syndrome encompassing a large spectrum of mechanisms and outcomes. The European Society of Cardiology published an update of the Syncope Guidelines in 2018. The aim of the present survey was to capture contemporary management of syncope and guideline implementation among European physicians. A 23-item questionnaire was presented to 2588 European Heart Rhythm Association (EHRA) members from 32 European countries. The response rate was 48%, but only complete responses (nâ=â161) were included in this study. The questionnaire contained specific items regarding syncope facilities, diagnostic definitions, diagnostic tools, follow-up, and therapy. The survey revealed that many respondents did not have syncope units (88%) or dedicated management algorithms (44%) at their institutions, and 45% of the respondents reported syncope-related hospitalization rates >25%, whereas most (95%) employed close monitoring and hospitalization in syncope patients with structural heart disease. Carotid sinus massage, autonomic testing, and tilt-table testing were inconsistently used. Indications were heterogeneous for implanted loop recorders (79% considered them for recurrent syncope in high-risk patients) or electrophysiological studies (67% considered them in bifascicular block and inconclusive non-invasive testing). Non-pharmacological therapy was consistently considered by 68% of respondents; however, there was important variation regarding the choice of drug and device therapy. While revealing an increased awareness of syncope and good practice, our study identified important unmet needs regarding the optimal management of syncope and variable syncope guideline implementation
Contemporary management of ventricular electrical storm in Europe: results of a European Heart Rhythm Association Survey
Electrical storm (ES) is a predictor of mortality, and its treatment is challenging. Moreover, not all potential therapeutic strategies are available in all hospitals, and a standardized approach among European centres is lacking. The aim of this European Heart Rhythm Association (EHRA) survey was to assess the current management of patients with ES both in the acute and post-acute phases in 102 different European centres. A 20-item online questionnaire was sent out to the EHRA Research Network Centres. The median number of patients with ES treated annually per centre is 10 (IQR 5-15). The possibility of using autonomic modulation (e.g. percutaneous stellate ganglion block or thoracic epidural anaesthesia) for the acute ES treatment is available in only 29.3% of the centres. Moreover, although over 80% of centres perform ventricular tachycardia ablation, this procedure is available 24/7 in only 16.5% of the hospitals. There is a significant heterogeneity among centres regarding the availability of AADs and their use before deciding to proceed with a non-AAD strategy; specifically, 4.4% of centres use only one drug, 33.3% use two drugs, and 12.2% >two drugs, while about 50% of the centres decide based on individual patient's characteristics. Regarding the type of AADs used for the acute and post-acute management of ES patients, important variability is reported depending upon the underlying heart disease. Most patients considered for percutaneous ablation have structural heart disease. Only 46% of centres refer patients to psychological counselling after ES
Rhythm monitoring, success definition, recurrence, and anticoagulation after atrial fibrillation ablation : results from an EHRA survey
Atrial fibrillation (AF) is a major challenge for the healthcare field. Pulmonary vein isolation is the most effective treatment for the maintenance of sinus rhythm. However, clinical endpoints for the procedure vary significantly among studies. There is no consensus on the definition of recurrence and no clear roadmap on how to deal with recurrences after a failed ablation. The purpose of this study was to perform a survey in order to show how clinicians currently approach this knowledge gap. An online survey, supported by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee, was conducted between 1 April 2022 and 8 May 2022. An anonymous questionnaire was disseminated via social media and EHRA newsletters, for clinicians to complete. This consisted of 18 multiple-choice questions regarding rhythm monitoring, definitions of a successful ablation, clinical practices after a failed AF ablation, and the continuance of anticoagulation. A total of 107 replies were collected across Europe. Most respondents (82%) perform routine monitoring for AF recurrences after ablation, with 51% of them preferring a long-term monitoring strategy. Cost was reported to have an impact on the choice of monitoring strategy. Self-screening was recommended by most (71%) of the respondents. The combination of absence of symptoms and recorded AF was the definition of success for most (83%) of the respondents. Cessation of anticoagulation after ablation was an option mostly for patients with paroxysmal AF and a low CHADS-VASc score. The majority of physicians perform routine monitoring after AF ablation. For most physicians, the combination of the absence of symptoms and electrocardiographic endpoints defines a successful result after AF ablation
Implantable Cardioverter-Defibrillators in Poland Compared with other European Countries from the Patient's Perspective : Insights from the EHRA Patient Survey
Background: The aim of this study was to compare differences between Polish ICD recipients and ICD recipients from other European countries in terms of quality of life, information provision before ICD implantation, and end-of-life issues. Methods: This is a sub-analysis of the "Living with an ICD" patient survey (25-item questionnaire) organized by the European Heart Rhythm Association between 12 April 2021 and 5 July 2021 in ten European countries. Results: There were 410 (22.7%) patients from Poland and 1399 (77.3%) from other European countries. A total of 51.0% of Polish patients reported improvement in their quality of life compared with 44.3% in other countries (p = 0.041). Remote monitoring was three times more often utilized in other countries than in Poland (66.8% vs. 21.0%, p < 0.001). While 78.1% of Poles felt well informed before ICD implantation compared with 69.6% of subjects from other countries (p = 0.001), they were less familiar with the ICD deactivation process than others (38.9% vs. 52.5%, p < 0.001). Conclusions: Despite the less frequent use of remote monitoring and gaps in end-of-life issues, Polish ICD recipients reported more favorable quality of life and a higher level of information received before device placement than patients in other European countries
Regional disparity on patient characteristics and perceptions after implantable cardioverter-defibrillator implantation : results from an EHRA patient survey
The aim of this study was to identify potential regional disparities in characteristics of implantable cardioverter-defibrillator (ICD) recipients, patient perceptions and perspectives after implantation and level of information provided to patients. The prospective, multicentre, and multinational European Heart Rhythm Association patient Survey 'Living with an ICD' included patients already implanted with an ICD (median ICD dwell time - 5 years, interquartile range 2-10). An online questionnaire was filled-in by patients invited from 10 European countries. A total of 1809 patients (the majority in their 40s to 70s, 65.5% men) were enrolled, with 877 (48.5%) from Western Europe (group 1), followed by 563 from Central/Eastern Europe (group 2, 31.1%), and 369 from Southern Europe (group 3, 20.4%). A total of 52.9% of Central/Eastern Europe patients reported increased satisfaction after ICD placement compared with 46.6% from Western and 33.1% from Southern Europe (1 vs. 2 P = 0.047, 1 vs. 3 P < 0.001, 2 vs. 3 P < 0.001). About 79.2% of Central/Eastern and 76.0% of Southern Europe patients felt optimally informed at the time of device implantation compared with just 64.6% from Western Europe (1 vs. 2 P < 0.001, 1 vs. 3 P < 0.001, 2 vs. 3 P = ns). While physicians in Southern Europe should address the patients' concerns about the impact of the ICD on quality of life, physicians from Western Europe should focus on improving the quality of information provided to their prospective ICD patients. Novel strategies to address regional differences in patients' quality of life and provision of information are warranted