11 research outputs found

    Data envelopment analysis and Malmquist indices for measuring group performance

    No full text
    This paper develops measures, based on the Malmquist index, that enable the decision making units' internal inefficiencies to be distinguished from those associated with their group (or program) characteristics. The applicability of these measures is illustrated with the assessment of bank branches' performance. The analysis involves the construction of an index reflecting the relative performance of branches in four different regions, which can be decomposed into an index for the comparison of within-group efficiency spread, evaluating internal managerial efficiencies, and an index for the comparison of frontier productivity, reflecting the impact of environmental factors and regional managerial policies on branches' productivity

    Coincidence timing of femtosecond optical pulses in an X-ray free electron laser

    No full text
    Femtosecond resolution pump-probe experiments are now routinely carried out at X-ray Free Electron Lasers, enabled by the development of cross-correlation “time-tools” which correct the picosecond-level jitter between the optical and X-ray pulses. These tools provide very accurate, <10 fs, measurement of the relative arrival time, but do not provide a measure of the absolute coincidence time in the interaction. Cross-correlation experiments using transient reflectivity in a crystal are commonly used for this purpose, and to date no quantitative analysis of the accuracy or stability of absolute coincidence time determination has been performed. We have performed a quantitative analysis of coincidence timing at the SACLA facility through a cross-correlation of 100 6 10 fs, 400 nm optical pulses with 7 fs, 10.5 keV X-ray pulses via transient reflectivity in a cerium-doped yttrium aluminum garnet crystal. We have modelled and fit the transient reflectivity, which required a convolution with a 226 6 12 fs uncertainty that was believed to be dominated by X-ray and laser intensity fluctuations, or assuming an extinction depth of 13.3 lm greater than the literature value of 66.7 lm. Despite this, we are able to determine the absolute coincidence time to an accuracy of 30 fs. We discuss the physical contributions to the uncertainty of coincidence time determination, which may include an uncharacterised offset delay in the development of transient reflectivity, including cascading Auger decays, secondary ionisation and cooling processes. Additionally, we present measurements of the intrinsic short-term and long-term drifts between the X-rays and the optical laser timing from time-tool analysis, which is dominated by a thermal expansion of the 25 m optical path between tool and the interaction region, seen to be 60 fs over a period of 5 h

    Pathogenese und Morphologie der epithelialen Hauttumoren bei der Ratte

    No full text
    corecore