65 research outputs found

    Prognostic role of minimal residual disease before and after hematopoietic stem cell transplantation in childhood acute lymphoblastic leukemia

    Get PDF
    More than 80% of children with acute lymphoblastic leukemia (ALL) can be cured through intensive and risk-oriented chemotherapy protocols. Allogeneic hematopoietic stem cell transplantation (HSCT) is considered bene\ufb01cial for approximately 10% of the patients who are at veryhigh risk at frontline therapy and for the majority of patients after relapse. Consequently, it is critically important to identify prognostic factors in this group of patients in order to tailor risk-adapted therapy. In this retrospective study, we aimed to assess the prognostic role of minimal residual disease (MRD) before HSCT and at di\ufb00erent time points after transplantation in children with ALL

    Cytokine-Induced Killer (CIK) Cells, In Vitro Expanded under Good Manufacturing Process (GMP) Conditions, Remain Stable over Time after Cryopreservation

    Get PDF
    Cytokine-induced killer (CIK) cells are advanced therapy medicinal products, so their production and freezing process has to be validated before their clinical use, to verify their stability as a drug formulation according to the good manufacturing practice (GMP) guidelines. We designed a stability program for our GMP-manufactured CIK cells, evaluating the viability, identity and potency of cryopreserved CIK cells at varying time periods from freezing, and compared them with fresh CIK cells. We evaluated the effects of the cryopreservation method, transportation, and the length of time of different process phases (pre-freezing, freezing and post-thawing) on the stability of CIK cells. This included a worst case for each stage. The expanded CIK cells were viable for up to 30 min from the addition of the freezing solution, when transported on dry ice within 48 h once frozen, within 60 min from thawing and from 12 months of freezing while preserving their cytotoxic effects. The reference samples, cryopreserved simultaneously in tubes and following the same method, were considered representative of the batch and useful in the case of further analysis. Data obtained from this drug stability program can inform the accurate use of CIK cells in clinical settings

    Validation of analytical methods in compliance with good manufacturing practice: A practical approach

    Get PDF
    BACKGROUND: The quality and safety of cell therapy products must be maintained throughout their production and quality control cycle, ensuring their final use in the patient. We validated the Lymulus Amebocyte Lysate (LAL) test and immunophenotype according to International Conference on Harmonization Q2 Guidelines and the EU Pharmacopoeia, considering accuracy, precision, repeatability, linearity and range. METHODS: For the endotoxin test we used a kinetic chromogenic LAL test. As this is a limit test for the control of impurities, in compliance with International Conference on Harmonization Q2 Guidelines and the EU Pharmacopoeia, we evaluated the specificity and detection limit. For the immunophenotype test, an identity test, we evaluated specificity through the Fluorescence Minus One method and we repeated all experiments thrice to verify precision. The immunophenotype validation required a performance qualification of the flow cytometer using two types of standard beads which have to be used daily to check cytometer reproducibly set up. The results were compared together. Collected data were statistically analyzed calculating mean, standard deviation and coefficient of variation percentage (CV%). RESULTS: The LAL test is repeatable and specific. The spike recovery value of each sample was between 0.25 EU/ml and 1 EU/ml with a CV% < 10%. The correlation coefficient (≥ 0.980) and CV% (< 10%) of the standard curve tested in duplicate showed the test's linearity and a minimum detectable concentration value of 0.005 EU/ml. The immunophenotype method performed thrice on our cell therapy products is specific and repeatable as showed by CV% inter -experiment < 10%. CONCLUSIONS: Our data demonstrated that validated analytical procedures are suitable as quality controls for the batch release of cell therapy products. Our paper could offer an important contribution for the scientific community in the field of CTPs, above all to small Cell Factories such as ours, where it is not always possible to have CFR21 compliant software

    Bacterial ligands as flexible and sensitive detectors in rapid tests for antibodies to SARS-CoV-2

    Get PDF
    Lateral flow immunoassay (LFIA) is widely employed as point-of-care tests (POCT) for the diagnosis of infectious diseases. The accuracy of LFIA largely depends on the quality of the immunoreagents used. Typical LFIAs to reveal the immune response to severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) employ anti-human immunoglobulin (hIG) antibodies and recombinant viral antigens, which usually are unstable and poorly soluble. Broad selective bacterial proteins, such as Staphylococcal protein A (SpA) and Streptococcal protein G (SpG) can be considered alternatives to anti-hIG to increase versatility and sensitivity of serological LFIAs because of their high binding capacity, interspecies reactivity, and robustness. We developed two colorimetric LFA devices including SpA and SpG linked to gold nanoparticles (GNP) as detectors and explored the use of a specific, stable, and soluble immunodominant fraction of the nucleocapsid protein from SARS-CoV-2 as the capturing agent. The optimal amount of SpA-GNP and SpG-GNP conjugates and the protein-to-GNP ratios were defined through a full factorial experimental design to maximize the diagnostic sensitivity of the LFIAs. The new LFA devices were applied to analyze 105 human serum samples (69 positive and 36 negatives according to reference molecular diagnostic methods). The results showed higher sensitivity (89.9%, 95% CI 82.7-97.0) and selectivity (91.7%, 82.6-100) for the SpA-based compared to the SpG-based LFA. In addition, 18 serum samples from cats and dogs living with COVID-19 patients were analyzed and 14 showed detectable levels of anti-SARS-CoV-2 antibodies, thus illustrating the flexibility of the SpA- and SpG-based LFAs
    • …
    corecore