26 research outputs found
Morphology and dynamics of Venus's southern polar vortex reveal a drifting circulation
This was a last-minute invited contribution to coincide with the publication of the article "Venus’s Southern Polar Vortex
Reveals Precessing Circulation" in Science
Gamma-Ray Burst observations by the high-energy charged particle detector on board the CSES-01 satellite between 2019 and 2021
In this paper we report the detection of five strong Gamma-Ray Bursts (GRBs)
by the High-Energy Particle Detector (HEPD-01) mounted on board the China
Seismo-Electromagnetic Satellite (CSES-01), operational since 2018 on a
Sun-synchronous polar orbit at a 507 km altitude and 97
inclination. HEPD-01 was designed to detect high-energy electrons in the energy
range 3 - 100 MeV, protons in the range 30 - 300 MeV, and light nuclei in the
range 30 - 300 MeV/n. Nonetheless, Monte Carlo simulations have shown HEPD-01
is sensitive to gamma-ray photons in the energy range 300 keV - 50 MeV, even if
with a moderate effective area above 5 MeV. A dedicated time correlation
analysis between GRBs reported in literature and signals from a set of HEPD-01
trigger configuration masks has confirmed the anticipated detector sensitivity
to high-energy photons. A comparison between the simultaneous time profiles of
HEPD-01 electron fluxes and photons from GRB190114C, GRB190305A, GRB190928A,
GRB200826B and GRB211211A has shown a remarkable similarity, in spite of the
different energy ranges. The high-energy response, with peak sensitivity at
about 2 MeV, and moderate effective area of the detector in the actual flight
configuration explain why these five GRBs, characterised by a fluence above
3 10 erg cm in the energy interval 300 keV - 50
MeV, have been detected.Comment: Accepted for publication in The Astrophysical Journal (ApJ
ELENA representative shutter with glue thermal test
Description of thermal test of representative ELENA shutter with 3 point of glue at IAPS TV Facilit
ELENA SW threshold for anodes 1-4 in Extended Histogram mode
Test Report modo scientifico dello strumento SERENA/ELENA a bordo della missione BepiColomb
ELENA DAC ramp test
Test report della campagna dello strumento SERENA/ELENA a bordo di BepiColomb
ELENA FS vibration test report
ELENA FS (part of SERENA package for Bepi Colombo mission to Mercury) has been refurbished.
Vibration test has been planned to validate the insturment before ESA delivery. This document reports ELENA FS vibration test: selected test are resonance research and comparison with
the resonance spectra obtained at previous vibration test in November 201
ELENA FS test for on board procedure
Test Report di debug delle procedure sullo strumento SERENA/ELENA Flight Spare da eseguire a bordo della missione BepiColomb
ELENA test Ottobre 2020: Confronto modo S, SO e R
test report modi operativi dello strumento SERENA/ELENA Flight Spare della missione BepiColomb
ELENA Test modo R
Test report modi scientifici strumento SERENA/ELENA Flight Spare, missione BepiColomb
ELENA FS (Refurbished) Calibration Report
This document reports the results of ELENA FS calibration activity (after refurbishment), performed at IAPS in Roma @ TV facility with ENA/Ion beam in March 2018 (March 9th-March 21st).
The results are considered in comparison with science performance requirement and ELENA previous calibration reports